No. Time Source Destination Protocol Length Info 1 0.000000 0x0000 0x5964 ZigBee HA 49 ZCL Groups: Get Group Membership, Seq: 12 Frame 1: 49 bytes on wire (392 bits), 49 bytes captured (392 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x2ed9, Src: 0x0000 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 241 Destination PAN: 0x1234 Destination: 0x2ed9 Source: 0x0000 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Network Layer Data, Dst: 0x5964, Src: 0x0000 Frame Control Field: 0x0248, Frame Type: Data, Discover Route: Enable, Security Data Destination: 0x5964 Source: 0x0000 Radius: 10 Sequence Number: 186 ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 156409052 Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01) Key Sequence Number: 0 Message Integrity Code: 9e494aca [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 10, Src Endpt: 1 Frame Control Field: Data (0x00) Destination Endpoint: 10 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 1 Counter: 143 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x11) Sequence Number: 12 Command: Get Group Membership (0x02) Payload Group Count: 0 No. Time Source Destination Protocol Length Info 2 0.010939 0x0000 0x5964 ZigBee HA 49 ZCL Groups: Get Group Membership, Seq: 12 Frame 2: 49 bytes on wire (392 bits), 49 bytes captured (392 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x5964, Src: 0x2ed9 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 160 Destination PAN: 0x1234 Destination: 0x5964 Source: 0x2ed9 [Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d)] [Origin: 2] ZigBee Network Layer Data, Dst: 0x5964, Src: 0x0000 Frame Control Field: 0x0248, Frame Type: Data, Discover Route: Enable, Security Data Destination: 0x5964 Source: 0x0000 Radius: 9 Sequence Number: 186 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 57428782 Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d) Key Sequence Number: 0 Message Integrity Code: c9be1e52 [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 10, Src Endpt: 1 Frame Control Field: Data (0x00) Destination Endpoint: 10 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 1 Counter: 143 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x11) Sequence Number: 12 Command: Get Group Membership (0x02) Payload Group Count: 0 No. Time Source Destination Protocol Length Info 3 0.017008 0x5964 0x0000 ZigBee HA 64 ZCL Groups: Get Group Membership Response, Seq: 12 Frame 3: 64 bytes on wire (512 bits), 64 bytes captured (512 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x2ed9, Src: 0x5964 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 169 Destination PAN: 0x1234 Destination: 0x2ed9 Source: 0x5964 [Extended Source: NordicSe_a9:ed:f6:8a:d2 (f4:ce:36:a9:ed:f6:8a:d2)] [Origin: 3] ZigBee Network Layer Data, Dst: 0x0000, Src: 0x5964 Frame Control Field: 0x1a48, Frame Type: Data, Discover Route: Enable, Security, Destination, Extended Source Data Destination: 0x0000 Source: 0x5964 Radius: 30 Sequence Number: 114 Destination: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01) Extended Source: NordicSe_a9:ed:f6:8a:d2 (f4:ce:36:a9:ed:f6:8a:d2) ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 114 Extended Source: NordicSe_a9:ed:f6:8a:d2 (f4:ce:36:a9:ed:f6:8a:d2) Key Sequence Number: 0 Message Integrity Code: f822647d [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 1, Src Endpt: 10 Frame Control Field: Data (0x40) Destination Endpoint: 1 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 10 Counter: 158 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x19) Sequence Number: 12 Command: Get Group Membership Response (0x02) Payload Group Capacity: 8 Group Count: 0 No. Time Source Destination Protocol Length Info 4 0.028613 0x5964 0x0000 ZigBee HA 64 ZCL Groups: Get Group Membership Response, Seq: 12 Frame 4: 64 bytes on wire (512 bits), 64 bytes captured (512 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x0000, Src: 0x2ed9 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 161 Destination PAN: 0x1234 Destination: 0x0000 Source: 0x2ed9 [Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d)] [Origin: 2] ZigBee Network Layer Data, Dst: 0x0000, Src: 0x5964 Frame Control Field: 0x1a48, Frame Type: Data, Discover Route: Enable, Security, Destination, Extended Source Data Destination: 0x0000 Source: 0x5964 Radius: 29 Sequence Number: 114 Destination: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01) Extended Source: NordicSe_a9:ed:f6:8a:d2 (f4:ce:36:a9:ed:f6:8a:d2) ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 57428783 Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d) Key Sequence Number: 0 Message Integrity Code: 9442fa41 [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 1, Src Endpt: 10 Frame Control Field: Data (0x40) Destination Endpoint: 1 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 10 Counter: 158 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x19) Sequence Number: 12 Command: Get Group Membership Response (0x02) Payload Group Capacity: 8 Group Count: 0 No. Time Source Destination Protocol Length Info 5 0.035337 0x0000 0x5964 ZigBee 43 APS: Ack, Dst Endpt: 10, Src Endpt: 1 Frame 5: 43 bytes on wire (344 bits), 43 bytes captured (344 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x2ed9, Src: 0x0000 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 242 Destination PAN: 0x1234 Destination: 0x2ed9 Source: 0x0000 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Network Layer Data, Dst: 0x5964, Src: 0x0000 Frame Control Field: 0x0248, Frame Type: Data, Discover Route: Enable, Security Data Destination: 0x5964 Source: 0x0000 Radius: 10 Sequence Number: 187 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 156409053 Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01) Key Sequence Number: 0 Message Integrity Code: fdd0c14c [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Ack, Dst Endpt: 10, Src Endpt: 1 Frame Control Field: Ack (0x02) Destination Endpoint: 10 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 1 Counter: 158 No. Time Source Destination Protocol Length Info 6 0.046906 0x0000 0x5964 ZigBee 43 APS: Ack, Dst Endpt: 10, Src Endpt: 1 Frame 6: 43 bytes on wire (344 bits), 43 bytes captured (344 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x5964, Src: 0x2ed9 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 162 Destination PAN: 0x1234 Destination: 0x5964 Source: 0x2ed9 [Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d)] [Origin: 2] ZigBee Network Layer Data, Dst: 0x5964, Src: 0x0000 Frame Control Field: 0x0248, Frame Type: Data, Discover Route: Enable, Security Data Destination: 0x5964 Source: 0x0000 Radius: 9 Sequence Number: 187 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 57428784 Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d) Key Sequence Number: 0 Message Integrity Code: 00e4b947 [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Ack, Dst Endpt: 10, Src Endpt: 1 Frame Control Field: Ack (0x02) Destination Endpoint: 10 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 1 Counter: 158 No. Time Source Destination Protocol Length Info 7 24.804517 0x0000 0x5964 ZigBee HA 49 ZCL Groups: Get Group Membership, Seq: 41 Frame 7: 49 bytes on wire (392 bits), 49 bytes captured (392 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x2ed9, Src: 0x0000 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 138 Destination PAN: 0x1234 Destination: 0x2ed9 Source: 0x0000 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Network Layer Data, Dst: 0x5964, Src: 0x0000 Frame Control Field: 0x0248, Frame Type: Data, Discover Route: Enable, Security Data Destination: 0x5964 Source: 0x0000 Radius: 10 Sequence Number: 78 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 156409201 Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01) Key Sequence Number: 0 Message Integrity Code: c0d30402 [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 11, Src Endpt: 1 Frame Control Field: Data (0x00) Destination Endpoint: 11 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 1 Counter: 218 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x11) Sequence Number: 41 Command: Get Group Membership (0x02) Payload Group Count: 0 No. Time Source Destination Protocol Length Info 8 24.816498 0x0000 0x5964 ZigBee HA 49 ZCL Groups: Get Group Membership, Seq: 41 Frame 8: 49 bytes on wire (392 bits), 49 bytes captured (392 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x5964, Src: 0x2ed9 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 209 Destination PAN: 0x1234 Destination: 0x5964 Source: 0x2ed9 [Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d)] [Origin: 2] ZigBee Network Layer Data, Dst: 0x5964, Src: 0x0000 Frame Control Field: 0x0248, Frame Type: Data, Discover Route: Enable, Security Data Destination: 0x5964 Source: 0x0000 Radius: 9 Sequence Number: 78 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 57428831 Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d) Key Sequence Number: 0 Message Integrity Code: 490370f8 [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 11, Src Endpt: 1 Frame Control Field: Data (0x00) Destination Endpoint: 11 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 1 Counter: 218 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x11) Sequence Number: 41 Command: Get Group Membership (0x02) Payload Group Count: 0 No. Time Source Destination Protocol Length Info 9 24.821608 0x5964 0x0000 ZigBee HA 64 ZCL Groups: Get Group Membership Response, Seq: 41 Frame 9: 64 bytes on wire (512 bits), 64 bytes captured (512 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x2ed9, Src: 0x5964 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 181 Destination PAN: 0x1234 Destination: 0x2ed9 Source: 0x5964 [Extended Source: NordicSe_a9:ed:f6:8a:d2 (f4:ce:36:a9:ed:f6:8a:d2)] [Origin: 3] ZigBee Network Layer Data, Dst: 0x0000, Src: 0x5964 Frame Control Field: 0x1a48, Frame Type: Data, Discover Route: Enable, Security, Destination, Extended Source Data Destination: 0x0000 Source: 0x5964 Radius: 30 Sequence Number: 126 Destination: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01) Extended Source: NordicSe_a9:ed:f6:8a:d2 (f4:ce:36:a9:ed:f6:8a:d2) ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 126 Extended Source: NordicSe_a9:ed:f6:8a:d2 (f4:ce:36:a9:ed:f6:8a:d2) Key Sequence Number: 0 Message Integrity Code: 8b88650f [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 1, Src Endpt: 11 Frame Control Field: Data (0x40) Destination Endpoint: 1 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 11 Counter: 170 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x19) Sequence Number: 41 Command: Get Group Membership Response (0x02) Payload Group Capacity: 8 Group Count: 0 No. Time Source Destination Protocol Length Info 10 24.834201 0x5964 0x0000 ZigBee HA 64 ZCL Groups: Get Group Membership Response, Seq: 41 Frame 10: 64 bytes on wire (512 bits), 64 bytes captured (512 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x0000, Src: 0x2ed9 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 210 Destination PAN: 0x1234 Destination: 0x0000 Source: 0x2ed9 [Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d)] [Origin: 2] ZigBee Network Layer Data, Dst: 0x0000, Src: 0x5964 Frame Control Field: 0x1a48, Frame Type: Data, Discover Route: Enable, Security, Destination, Extended Source Data Destination: 0x0000 Source: 0x5964 Radius: 29 Sequence Number: 126 Destination: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01) Extended Source: NordicSe_a9:ed:f6:8a:d2 (f4:ce:36:a9:ed:f6:8a:d2) ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 57428832 Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d) Key Sequence Number: 0 Message Integrity Code: 2b291d9d [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 1, Src Endpt: 11 Frame Control Field: Data (0x40) Destination Endpoint: 1 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 11 Counter: 170 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x19) Sequence Number: 41 Command: Get Group Membership Response (0x02) Payload Group Capacity: 8 Group Count: 0 No. Time Source Destination Protocol Length Info 11 24.839661 0x0000 0x5964 ZigBee 43 APS: Ack, Dst Endpt: 11, Src Endpt: 1 Frame 11: 43 bytes on wire (344 bits), 43 bytes captured (344 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x2ed9, Src: 0x0000 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 139 Destination PAN: 0x1234 Destination: 0x2ed9 Source: 0x0000 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Network Layer Data, Dst: 0x5964, Src: 0x0000 Frame Control Field: 0x0248, Frame Type: Data, Discover Route: Enable, Security Data Destination: 0x5964 Source: 0x0000 Radius: 10 Sequence Number: 79 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 156409202 Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01) Key Sequence Number: 0 Message Integrity Code: fadad311 [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Ack, Dst Endpt: 11, Src Endpt: 1 Frame Control Field: Ack (0x02) Destination Endpoint: 11 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 1 Counter: 170 No. Time Source Destination Protocol Length Info 12 24.851376 0x0000 0x5964 ZigBee 43 APS: Ack, Dst Endpt: 11, Src Endpt: 1 Frame 12: 43 bytes on wire (344 bits), 43 bytes captured (344 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x5964, Src: 0x2ed9 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 211 Destination PAN: 0x1234 Destination: 0x5964 Source: 0x2ed9 [Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d)] [Origin: 2] ZigBee Network Layer Data, Dst: 0x5964, Src: 0x0000 Frame Control Field: 0x0248, Frame Type: Data, Discover Route: Enable, Security Data Destination: 0x5964 Source: 0x0000 Radius: 9 Sequence Number: 79 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 57428833 Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d) Key Sequence Number: 0 Message Integrity Code: d373d554 [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Ack, Dst Endpt: 11, Src Endpt: 1 Frame Control Field: Ack (0x02) Destination Endpoint: 11 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 1 Counter: 170 No. Time Source Destination Protocol Length Info 13 48.327770 0x0000 0x5964 ZigBee HA 49 ZCL Groups: Add Group, Seq: 66 Frame 13: 49 bytes on wire (392 bits), 49 bytes captured (392 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x2ed9, Src: 0x0000 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 43 Destination PAN: 0x1234 Destination: 0x2ed9 Source: 0x0000 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Network Layer Data, Dst: 0x5964, Src: 0x0000 Frame Control Field: 0x0248, Frame Type: Data, Discover Route: Enable, Security Data Destination: 0x5964 Source: 0x0000 Radius: 10 Sequence Number: 228 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 156409354 Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01) Key Sequence Number: 0 Message Integrity Code: f7085222 [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 10, Src Endpt: 1 Frame Control Field: Data (0x00) Destination Endpoint: 10 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 1 Counter: 39 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x11) Sequence Number: 66 Command: Add Group (0x00) Payload, String: Group ID: 0x000a Length: 0 String: No. Time Source Destination Protocol Length Info 14 48.398397 0x5964 0x0000 ZigBee HA 65 ZCL Groups: Add Group Response, Seq: 66 Frame 14: 65 bytes on wire (520 bits), 65 bytes captured (520 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x2ed9, Src: 0x5964 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 193 Destination PAN: 0x1234 Destination: 0x2ed9 Source: 0x5964 [Extended Source: NordicSe_a9:ed:f6:8a:d2 (f4:ce:36:a9:ed:f6:8a:d2)] [Origin: 3] ZigBee Network Layer Data, Dst: 0x0000, Src: 0x5964 Frame Control Field: 0x1a48, Frame Type: Data, Discover Route: Enable, Security, Destination, Extended Source Data Destination: 0x0000 Source: 0x5964 Radius: 30 Sequence Number: 138 Destination: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01) Extended Source: NordicSe_a9:ed:f6:8a:d2 (f4:ce:36:a9:ed:f6:8a:d2) ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 138 Extended Source: NordicSe_a9:ed:f6:8a:d2 (f4:ce:36:a9:ed:f6:8a:d2) Key Sequence Number: 0 Message Integrity Code: 5b69f2ce [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 1, Src Endpt: 10 Frame Control Field: Data (0x40) Destination Endpoint: 1 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 10 Counter: 182 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x19) Sequence Number: 66 Command: Add Group Response (0x00) Payload Group Status: Success (0x00) Group ID: 0x000a No. Time Source Destination Protocol Length Info 15 48.411677 0x5964 0x0000 ZigBee HA 65 ZCL Groups: Add Group Response, Seq: 66 Frame 15: 65 bytes on wire (520 bits), 65 bytes captured (520 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x0000, Src: 0x2ed9 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 0 Destination PAN: 0x1234 Destination: 0x0000 Source: 0x2ed9 [Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d)] [Origin: 2] ZigBee Network Layer Data, Dst: 0x0000, Src: 0x5964 Frame Control Field: 0x1a48, Frame Type: Data, Discover Route: Enable, Security, Destination, Extended Source Data Destination: 0x0000 Source: 0x5964 Radius: 29 Sequence Number: 138 Destination: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01) Extended Source: NordicSe_a9:ed:f6:8a:d2 (f4:ce:36:a9:ed:f6:8a:d2) ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 57428878 Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d) Key Sequence Number: 0 Message Integrity Code: f87f59a1 [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 1, Src Endpt: 10 Frame Control Field: Data (0x40) Destination Endpoint: 1 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 10 Counter: 182 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x19) Sequence Number: 66 Command: Add Group Response (0x00) Payload Group Status: Success (0x00) Group ID: 0x000a No. Time Source Destination Protocol Length Info 16 48.418378 0x0000 0x5964 ZigBee 43 APS: Ack, Dst Endpt: 10, Src Endpt: 1 Frame 16: 43 bytes on wire (344 bits), 43 bytes captured (344 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x2ed9, Src: 0x0000 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 44 Destination PAN: 0x1234 Destination: 0x2ed9 Source: 0x0000 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Network Layer Data, Dst: 0x5964, Src: 0x0000 Frame Control Field: 0x0248, Frame Type: Data, Discover Route: Enable, Security Data Destination: 0x5964 Source: 0x0000 Radius: 10 Sequence Number: 229 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 156409355 Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01) Key Sequence Number: 0 Message Integrity Code: b494dfb8 [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Ack, Dst Endpt: 10, Src Endpt: 1 Frame Control Field: Ack (0x02) Destination Endpoint: 10 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 1 Counter: 182 No. Time Source Destination Protocol Length Info 17 48.428188 0x0000 0x5964 ZigBee 43 APS: Ack, Dst Endpt: 10, Src Endpt: 1 Frame 17: 43 bytes on wire (344 bits), 43 bytes captured (344 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x5964, Src: 0x2ed9 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 1 Destination PAN: 0x1234 Destination: 0x5964 Source: 0x2ed9 [Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d)] [Origin: 2] ZigBee Network Layer Data, Dst: 0x5964, Src: 0x0000 Frame Control Field: 0x0248, Frame Type: Data, Discover Route: Enable, Security Data Destination: 0x5964 Source: 0x0000 Radius: 9 Sequence Number: 229 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 57428879 Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d) Key Sequence Number: 0 Message Integrity Code: 279e3ca4 [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Ack, Dst Endpt: 10, Src Endpt: 1 Frame Control Field: Ack (0x02) Destination Endpoint: 10 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 1 Counter: 182 No. Time Source Destination Protocol Length Info 18 57.142969 0x0000 0x5964 ZigBee HA 49 ZCL Groups: Add Group, Seq: 80 Frame 18: 49 bytes on wire (392 bits), 49 bytes captured (392 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x2ed9, Src: 0x0000 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 96 Destination PAN: 0x1234 Destination: 0x2ed9 Source: 0x0000 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Network Layer Data, Dst: 0x5964, Src: 0x0000 Frame Control Field: 0x0248, Frame Type: Data, Discover Route: Enable, Security Data Destination: 0x5964 Source: 0x0000 Radius: 10 Sequence Number: 19 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 156409403 Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01) Key Sequence Number: 0 Message Integrity Code: 9077f40e [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 11, Src Endpt: 1 Frame Control Field: Data (0x00) Destination Endpoint: 11 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 1 Counter: 62 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x11) Sequence Number: 80 Command: Add Group (0x00) Payload, String: Group ID: 0x000b Length: 0 String: No. Time Source Destination Protocol Length Info 19 57.152940 0x0000 0x5964 ZigBee HA 49 ZCL Groups: Add Group, Seq: 80 Frame 19: 49 bytes on wire (392 bits), 49 bytes captured (392 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x5964, Src: 0x2ed9 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 7 Destination PAN: 0x1234 Destination: 0x5964 Source: 0x2ed9 [Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d)] [Origin: 2] ZigBee Network Layer Data, Dst: 0x5964, Src: 0x0000 Frame Control Field: 0x0248, Frame Type: Data, Discover Route: Enable, Security Data Destination: 0x5964 Source: 0x0000 Radius: 9 Sequence Number: 19 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 57428885 Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d) Key Sequence Number: 0 Message Integrity Code: 5536407c [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 11, Src Endpt: 1 Frame Control Field: Data (0x00) Destination Endpoint: 11 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 1 Counter: 62 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x11) Sequence Number: 80 Command: Add Group (0x00) Payload, String: Group ID: 0x000b Length: 0 String: No. Time Source Destination Protocol Length Info 20 57.173676 0x5964 0x0000 ZigBee HA 65 ZCL Groups: Add Group Response, Seq: 80 Frame 20: 65 bytes on wire (520 bits), 65 bytes captured (520 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x2ed9, Src: 0x5964 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 194 Destination PAN: 0x1234 Destination: 0x2ed9 Source: 0x5964 [Extended Source: NordicSe_a9:ed:f6:8a:d2 (f4:ce:36:a9:ed:f6:8a:d2)] [Origin: 3] ZigBee Network Layer Data, Dst: 0x0000, Src: 0x5964 Frame Control Field: 0x1a48, Frame Type: Data, Discover Route: Enable, Security, Destination, Extended Source Data Destination: 0x0000 Source: 0x5964 Radius: 30 Sequence Number: 139 Destination: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01) Extended Source: NordicSe_a9:ed:f6:8a:d2 (f4:ce:36:a9:ed:f6:8a:d2) ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 139 Extended Source: NordicSe_a9:ed:f6:8a:d2 (f4:ce:36:a9:ed:f6:8a:d2) Key Sequence Number: 0 Message Integrity Code: c8d89bb0 [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 1, Src Endpt: 11 Frame Control Field: Data (0x40) Destination Endpoint: 1 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 11 Counter: 183 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x19) Sequence Number: 80 Command: Add Group Response (0x00) Payload Group Status: Success (0x00) Group ID: 0x000b No. Time Source Destination Protocol Length Info 21 57.184948 0x5964 0x0000 ZigBee HA 65 ZCL Groups: Add Group Response, Seq: 80 Frame 21: 65 bytes on wire (520 bits), 65 bytes captured (520 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x0000, Src: 0x2ed9 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 8 Destination PAN: 0x1234 Destination: 0x0000 Source: 0x2ed9 [Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d)] [Origin: 2] ZigBee Network Layer Data, Dst: 0x0000, Src: 0x5964 Frame Control Field: 0x1a48, Frame Type: Data, Discover Route: Enable, Security, Destination, Extended Source Data Destination: 0x0000 Source: 0x5964 Radius: 29 Sequence Number: 139 Destination: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01) Extended Source: NordicSe_a9:ed:f6:8a:d2 (f4:ce:36:a9:ed:f6:8a:d2) ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 57428886 Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d) Key Sequence Number: 0 Message Integrity Code: 5aaeb85c [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 1, Src Endpt: 11 Frame Control Field: Data (0x40) Destination Endpoint: 1 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 11 Counter: 183 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x19) Sequence Number: 80 Command: Add Group Response (0x00) Payload Group Status: Success (0x00) Group ID: 0x000b No. Time Source Destination Protocol Length Info 22 57.190399 0x0000 0x5964 ZigBee 43 APS: Ack, Dst Endpt: 11, Src Endpt: 1 Frame 22: 43 bytes on wire (344 bits), 43 bytes captured (344 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x2ed9, Src: 0x0000 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 97 Destination PAN: 0x1234 Destination: 0x2ed9 Source: 0x0000 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Network Layer Data, Dst: 0x5964, Src: 0x0000 Frame Control Field: 0x0248, Frame Type: Data, Discover Route: Enable, Security Data Destination: 0x5964 Source: 0x0000 Radius: 10 Sequence Number: 20 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 156409404 Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01) Key Sequence Number: 0 Message Integrity Code: d0e49b1b [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Ack, Dst Endpt: 11, Src Endpt: 1 Frame Control Field: Ack (0x02) Destination Endpoint: 11 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 1 Counter: 183 No. Time Source Destination Protocol Length Info 23 57.199733 0x0000 0x5964 ZigBee 43 APS: Ack, Dst Endpt: 11, Src Endpt: 1 Frame 23: 43 bytes on wire (344 bits), 43 bytes captured (344 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x5964, Src: 0x2ed9 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 9 Destination PAN: 0x1234 Destination: 0x5964 Source: 0x2ed9 [Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d)] [Origin: 2] ZigBee Network Layer Data, Dst: 0x5964, Src: 0x0000 Frame Control Field: 0x0248, Frame Type: Data, Discover Route: Enable, Security Data Destination: 0x5964 Source: 0x0000 Radius: 9 Sequence Number: 20 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 57428887 Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d) Key Sequence Number: 0 Message Integrity Code: 4e5e7e39 [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Ack, Dst Endpt: 11, Src Endpt: 1 Frame Control Field: Ack (0x02) Destination Endpoint: 11 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 1 Counter: 183 No. Time Source Destination Protocol Length Info 24 68.873466 0x0000 0x5964 ZigBee HA 49 ZCL Groups: Get Group Membership, Seq: 88 Frame 24: 49 bytes on wire (392 bits), 49 bytes captured (392 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x2ed9, Src: 0x0000 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 152 Destination PAN: 0x1234 Destination: 0x2ed9 Source: 0x0000 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Network Layer Data, Dst: 0x5964, Src: 0x0000 Frame Control Field: 0x0248, Frame Type: Data, Discover Route: Enable, Security Data Destination: 0x5964 Source: 0x0000 Radius: 10 Sequence Number: 74 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 156409458 Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01) Key Sequence Number: 0 Message Integrity Code: 0832ad39 [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 10, Src Endpt: 1 Frame Control Field: Data (0x00) Destination Endpoint: 10 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 1 Counter: 90 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x11) Sequence Number: 88 Command: Get Group Membership (0x02) Payload Group Count: 0 No. Time Source Destination Protocol Length Info 25 68.884700 0x0000 0x5964 ZigBee HA 49 ZCL Groups: Get Group Membership, Seq: 88 Frame 25: 49 bytes on wire (392 bits), 49 bytes captured (392 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x5964, Src: 0x2ed9 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 16 Destination PAN: 0x1234 Destination: 0x5964 Source: 0x2ed9 [Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d)] [Origin: 2] ZigBee Network Layer Data, Dst: 0x5964, Src: 0x0000 Frame Control Field: 0x0248, Frame Type: Data, Discover Route: Enable, Security Data Destination: 0x5964 Source: 0x0000 Radius: 9 Sequence Number: 74 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 57428894 Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d) Key Sequence Number: 0 Message Integrity Code: 5540c44b [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 10, Src Endpt: 1 Frame Control Field: Data (0x00) Destination Endpoint: 10 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 1 Counter: 90 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x11) Sequence Number: 88 Command: Get Group Membership (0x02) Payload Group Count: 0 No. Time Source Destination Protocol Length Info 26 68.903359 0x5964 0x0000 ZigBee HA 68 ZCL Groups: Get Group Membership Response, Seq: 88 Frame 26: 68 bytes on wire (544 bits), 68 bytes captured (544 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x0000, Src: 0x2ed9 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 17 Destination PAN: 0x1234 Destination: 0x0000 Source: 0x2ed9 [Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d)] [Origin: 2] ZigBee Network Layer Data, Dst: 0x0000, Src: 0x5964 Frame Control Field: 0x1a48, Frame Type: Data, Discover Route: Enable, Security, Destination, Extended Source Data Destination: 0x0000 Source: 0x5964 Radius: 29 Sequence Number: 140 Destination: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01) Extended Source: NordicSe_a9:ed:f6:8a:d2 (f4:ce:36:a9:ed:f6:8a:d2) ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 57428895 Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d) Key Sequence Number: 0 Message Integrity Code: 1157b047 [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 1, Src Endpt: 10 Frame Control Field: Data (0x40) Destination Endpoint: 1 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 10 Counter: 184 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x19) Sequence Number: 88 Command: Get Group Membership Response (0x02) Payload Group Capacity: 6 Group Count: 2 Group List Group ID: 0x000a Group ID: 0x000b No. Time Source Destination Protocol Length Info 27 68.913210 0x5964 0x0000 ZigBee HA 68 ZCL Groups: Get Group Membership Response, Seq: 88 Frame 27: 68 bytes on wire (544 bits), 68 bytes captured (544 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x0000, Src: 0x2ed9 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 17 Destination PAN: 0x1234 Destination: 0x0000 Source: 0x2ed9 [Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d)] [Origin: 2] ZigBee Network Layer Data, Dst: 0x0000, Src: 0x5964 Frame Control Field: 0x1a48, Frame Type: Data, Discover Route: Enable, Security, Destination, Extended Source Data Destination: 0x0000 Source: 0x5964 Radius: 29 Sequence Number: 140 Destination: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01) Extended Source: NordicSe_a9:ed:f6:8a:d2 (f4:ce:36:a9:ed:f6:8a:d2) ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 57428895 Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d) Key Sequence Number: 0 Message Integrity Code: 1157b047 [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 1, Src Endpt: 10 Frame Control Field: Data (0x40) Destination Endpoint: 1 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 10 Counter: 184 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x19) Sequence Number: 88 Command: Get Group Membership Response (0x02) Payload Group Capacity: 6 Group Count: 2 Group List Group ID: 0x000a Group ID: 0x000b No. Time Source Destination Protocol Length Info 28 68.920166 0x0000 0x5964 ZigBee 43 APS: Ack, Dst Endpt: 10, Src Endpt: 1 Frame 28: 43 bytes on wire (344 bits), 43 bytes captured (344 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x2ed9, Src: 0x0000 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 154 Destination PAN: 0x1234 Destination: 0x2ed9 Source: 0x0000 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Network Layer Data, Dst: 0x5964, Src: 0x0000 Frame Control Field: 0x0248, Frame Type: Data, Discover Route: Enable, Security Data Destination: 0x5964 Source: 0x0000 Radius: 10 Sequence Number: 76 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 156409460 Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01) Key Sequence Number: 0 Message Integrity Code: ca53c6d8 [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Ack, Dst Endpt: 10, Src Endpt: 1 Frame Control Field: Ack (0x02) Destination Endpoint: 10 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 1 Counter: 184 No. Time Source Destination Protocol Length Info 29 68.929500 0x0000 0x5964 ZigBee 43 APS: Ack, Dst Endpt: 10, Src Endpt: 1 Frame 29: 43 bytes on wire (344 bits), 43 bytes captured (344 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x5964, Src: 0x2ed9 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 18 Destination PAN: 0x1234 Destination: 0x5964 Source: 0x2ed9 [Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d)] [Origin: 2] ZigBee Network Layer Data, Dst: 0x5964, Src: 0x0000 Frame Control Field: 0x0248, Frame Type: Data, Discover Route: Enable, Security Data Destination: 0x5964 Source: 0x0000 Radius: 9 Sequence Number: 76 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 57428896 Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d) Key Sequence Number: 0 Message Integrity Code: d88e6056 [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Ack, Dst Endpt: 10, Src Endpt: 1 Frame Control Field: Ack (0x02) Destination Endpoint: 10 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 1 Counter: 184 No. Time Source Destination Protocol Length Info 30 79.960736 0x0000 0x5964 ZigBee HA 49 ZCL Groups: Get Group Membership, Seq: 103 Frame 30: 49 bytes on wire (392 bits), 49 bytes captured (392 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x2ed9, Src: 0x0000 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 227 Destination PAN: 0x1234 Destination: 0x2ed9 Source: 0x0000 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Network Layer Data, Dst: 0x5964, Src: 0x0000 Frame Control Field: 0x0248, Frame Type: Data, Discover Route: Enable, Security Data Destination: 0x5964 Source: 0x0000 Radius: 10 Sequence Number: 149 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 156409533 Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01) Key Sequence Number: 0 Message Integrity Code: eb54d79d [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 11, Src Endpt: 1 Frame Control Field: Data (0x00) Destination Endpoint: 11 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 1 Counter: 129 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x11) Sequence Number: 103 Command: Get Group Membership (0x02) Payload Group Count: 0 No. Time Source Destination Protocol Length Info 31 79.970662 0x0000 0x5964 ZigBee HA 49 ZCL Groups: Get Group Membership, Seq: 103 Frame 31: 49 bytes on wire (392 bits), 49 bytes captured (392 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x5964, Src: 0x2ed9 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 20 Destination PAN: 0x1234 Destination: 0x5964 Source: 0x2ed9 [Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d)] [Origin: 2] ZigBee Network Layer Data, Dst: 0x5964, Src: 0x0000 Frame Control Field: 0x0248, Frame Type: Data, Discover Route: Enable, Security Data Destination: 0x5964 Source: 0x0000 Radius: 9 Sequence Number: 149 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 57428898 Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d) Key Sequence Number: 0 Message Integrity Code: c6ba2dde [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 11, Src Endpt: 1 Frame Control Field: Data (0x00) Destination Endpoint: 11 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 1 Counter: 129 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x11) Sequence Number: 103 Command: Get Group Membership (0x02) Payload Group Count: 0 No. Time Source Destination Protocol Length Info 32 79.977521 0x5964 0x0000 ZigBee HA 68 ZCL Groups: Get Group Membership Response, Seq: 103 Frame 32: 68 bytes on wire (544 bits), 68 bytes captured (544 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x2ed9, Src: 0x5964 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 196 Destination PAN: 0x1234 Destination: 0x2ed9 Source: 0x5964 [Extended Source: NordicSe_a9:ed:f6:8a:d2 (f4:ce:36:a9:ed:f6:8a:d2)] [Origin: 3] ZigBee Network Layer Data, Dst: 0x0000, Src: 0x5964 Frame Control Field: 0x1a48, Frame Type: Data, Discover Route: Enable, Security, Destination, Extended Source Data Destination: 0x0000 Source: 0x5964 Radius: 30 Sequence Number: 141 Destination: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01) Extended Source: NordicSe_a9:ed:f6:8a:d2 (f4:ce:36:a9:ed:f6:8a:d2) ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 141 Extended Source: NordicSe_a9:ed:f6:8a:d2 (f4:ce:36:a9:ed:f6:8a:d2) Key Sequence Number: 0 Message Integrity Code: bd3cebb2 [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 1, Src Endpt: 11 Frame Control Field: Data (0x40) Destination Endpoint: 1 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 11 Counter: 185 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x19) Sequence Number: 103 Command: Get Group Membership Response (0x02) Payload Group Capacity: 6 Group Count: 2 Group List Group ID: 0x000a Group ID: 0x000b No. Time Source Destination Protocol Length Info 33 79.990813 0x5964 0x0000 ZigBee HA 68 ZCL Groups: Get Group Membership Response, Seq: 103 Frame 33: 68 bytes on wire (544 bits), 68 bytes captured (544 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x0000, Src: 0x2ed9 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 21 Destination PAN: 0x1234 Destination: 0x0000 Source: 0x2ed9 [Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d)] [Origin: 2] ZigBee Network Layer Data, Dst: 0x0000, Src: 0x5964 Frame Control Field: 0x1a48, Frame Type: Data, Discover Route: Enable, Security, Destination, Extended Source Data Destination: 0x0000 Source: 0x5964 Radius: 29 Sequence Number: 141 Destination: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01) Extended Source: NordicSe_a9:ed:f6:8a:d2 (f4:ce:36:a9:ed:f6:8a:d2) ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 57428899 Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d) Key Sequence Number: 0 Message Integrity Code: 0e024f46 [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 1, Src Endpt: 11 Frame Control Field: Data (0x40) Destination Endpoint: 1 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 11 Counter: 185 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x19) Sequence Number: 103 Command: Get Group Membership Response (0x02) Payload Group Capacity: 6 Group Count: 2 Group List Group ID: 0x000a Group ID: 0x000b No. Time Source Destination Protocol Length Info 34 79.997525 0x0000 0x5964 ZigBee 43 APS: Ack, Dst Endpt: 11, Src Endpt: 1 Frame 34: 43 bytes on wire (344 bits), 43 bytes captured (344 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x2ed9, Src: 0x0000 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 228 Destination PAN: 0x1234 Destination: 0x2ed9 Source: 0x0000 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Network Layer Data, Dst: 0x5964, Src: 0x0000 Frame Control Field: 0x0248, Frame Type: Data, Discover Route: Enable, Security Data Destination: 0x5964 Source: 0x0000 Radius: 10 Sequence Number: 150 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 156409534 Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01) Key Sequence Number: 0 Message Integrity Code: 0aa71714 [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Ack, Dst Endpt: 11, Src Endpt: 1 Frame Control Field: Ack (0x02) Destination Endpoint: 11 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 1 Counter: 185 No. Time Source Destination Protocol Length Info 35 80.007539 0x0000 0x5964 ZigBee 43 APS: Ack, Dst Endpt: 11, Src Endpt: 1 Frame 35: 43 bytes on wire (344 bits), 43 bytes captured (344 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x5964, Src: 0x2ed9 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 22 Destination PAN: 0x1234 Destination: 0x5964 Source: 0x2ed9 [Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d)] [Origin: 2] ZigBee Network Layer Data, Dst: 0x5964, Src: 0x0000 Frame Control Field: 0x0248, Frame Type: Data, Discover Route: Enable, Security Data Destination: 0x5964 Source: 0x0000 Radius: 9 Sequence Number: 150 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 57428900 Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d) Key Sequence Number: 0 Message Integrity Code: 5bacaeaa [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Ack, Dst Endpt: 11, Src Endpt: 1 Frame Control Field: Ack (0x02) Destination Endpoint: 11 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 1 Counter: 185 No. Time Source Destination Protocol Length Info 36 98.384985 0x0000 0x5964 ZigBee HA 48 ZCL Groups: View Group, Seq: 123 Frame 36: 48 bytes on wire (384 bits), 48 bytes captured (384 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x2ed9, Src: 0x0000 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 90 Destination PAN: 0x1234 Destination: 0x2ed9 Source: 0x0000 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Network Layer Data, Dst: 0x5964, Src: 0x0000 Frame Control Field: 0x0248, Frame Type: Data, Discover Route: Enable, Security Data Destination: 0x5964 Source: 0x0000 Radius: 10 Sequence Number: 254 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 156409642 Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01) Key Sequence Number: 0 Message Integrity Code: 59345abb [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 12, Src Endpt: 1 Frame Control Field: Data (0x00) Destination Endpoint: 12 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 1 Counter: 182 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x11) Sequence Number: 123 Command: View Group (0x01) Payload Group ID: 0x000a No. Time Source Destination Protocol Length Info 37 98.395867 0x0000 0x5964 ZigBee HA 48 ZCL Groups: View Group, Seq: 123 Frame 37: 48 bytes on wire (384 bits), 48 bytes captured (384 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x5964, Src: 0x2ed9 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 70 Destination PAN: 0x1234 Destination: 0x5964 Source: 0x2ed9 [Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d)] [Origin: 2] ZigBee Network Layer Data, Dst: 0x5964, Src: 0x0000 Frame Control Field: 0x0248, Frame Type: Data, Discover Route: Enable, Security Data Destination: 0x5964 Source: 0x0000 Radius: 9 Sequence Number: 254 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 57428948 Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d) Key Sequence Number: 0 Message Integrity Code: e231b25b [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 12, Src Endpt: 1 Frame Control Field: Data (0x00) Destination Endpoint: 12 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 1 Counter: 182 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x11) Sequence Number: 123 Command: View Group (0x01) Payload Group ID: 0x000a No. Time Source Destination Protocol Length Info 38 98.401027 0x5964 0x0000 ZigBee HA 66 ZCL Groups: View Group Response, Seq: 123 Frame 38: 66 bytes on wire (528 bits), 66 bytes captured (528 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x2ed9, Src: 0x5964 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 208 Destination PAN: 0x1234 Destination: 0x2ed9 Source: 0x5964 [Extended Source: NordicSe_a9:ed:f6:8a:d2 (f4:ce:36:a9:ed:f6:8a:d2)] [Origin: 3] ZigBee Network Layer Data, Dst: 0x0000, Src: 0x5964 Frame Control Field: 0x1a48, Frame Type: Data, Discover Route: Enable, Security, Destination, Extended Source Data Destination: 0x0000 Source: 0x5964 Radius: 30 Sequence Number: 153 Destination: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01) Extended Source: NordicSe_a9:ed:f6:8a:d2 (f4:ce:36:a9:ed:f6:8a:d2) ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 153 Extended Source: NordicSe_a9:ed:f6:8a:d2 (f4:ce:36:a9:ed:f6:8a:d2) Key Sequence Number: 0 Message Integrity Code: 61341d7a [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 1, Src Endpt: 12 Frame Control Field: Data (0x40) Destination Endpoint: 1 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 12 Counter: 197 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x19) Sequence Number: 123 Command: View Group Response (0x01) Payload, String: Group Status: Success (0x00) Group ID: 0x000a Length: 0 String: No. Time Source Destination Protocol Length Info 39 98.413898 0x5964 0x0000 ZigBee HA 66 ZCL Groups: View Group Response, Seq: 123 Frame 39: 66 bytes on wire (528 bits), 66 bytes captured (528 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x0000, Src: 0x2ed9 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 71 Destination PAN: 0x1234 Destination: 0x0000 Source: 0x2ed9 [Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d)] [Origin: 2] ZigBee Network Layer Data, Dst: 0x0000, Src: 0x5964 Frame Control Field: 0x1a48, Frame Type: Data, Discover Route: Enable, Security, Destination, Extended Source Data Destination: 0x0000 Source: 0x5964 Radius: 29 Sequence Number: 153 Destination: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01) Extended Source: NordicSe_a9:ed:f6:8a:d2 (f4:ce:36:a9:ed:f6:8a:d2) ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 57428949 Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d) Key Sequence Number: 0 Message Integrity Code: 755ec6eb [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 1, Src Endpt: 12 Frame Control Field: Data (0x40) Destination Endpoint: 1 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 12 Counter: 197 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x19) Sequence Number: 123 Command: View Group Response (0x01) Payload, String: Group Status: Success (0x00) Group ID: 0x000a Length: 0 String: No. Time Source Destination Protocol Length Info 40 98.421584 0x0000 0x5964 ZigBee 43 APS: Ack, Dst Endpt: 12, Src Endpt: 1 Frame 40: 43 bytes on wire (344 bits), 43 bytes captured (344 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x2ed9, Src: 0x0000 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 91 Destination PAN: 0x1234 Destination: 0x2ed9 Source: 0x0000 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Network Layer Data, Dst: 0x5964, Src: 0x0000 Frame Control Field: 0x0248, Frame Type: Data, Discover Route: Enable, Security Data Destination: 0x5964 Source: 0x0000 Radius: 10 Sequence Number: 255 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 156409643 Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01) Key Sequence Number: 0 Message Integrity Code: 2be85a9e [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Ack, Dst Endpt: 12, Src Endpt: 1 Frame Control Field: Ack (0x02) Destination Endpoint: 12 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 1 Counter: 197 No. Time Source Destination Protocol Length Info 41 98.432841 0x0000 0x5964 ZigBee 43 APS: Ack, Dst Endpt: 12, Src Endpt: 1 Frame 41: 43 bytes on wire (344 bits), 43 bytes captured (344 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x5964, Src: 0x2ed9 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 72 Destination PAN: 0x1234 Destination: 0x5964 Source: 0x2ed9 [Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d)] [Origin: 2] ZigBee Network Layer Data, Dst: 0x5964, Src: 0x0000 Frame Control Field: 0x0248, Frame Type: Data, Discover Route: Enable, Security Data Destination: 0x5964 Source: 0x0000 Radius: 9 Sequence Number: 255 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 57428950 Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d) Key Sequence Number: 0 Message Integrity Code: 91136aa8 [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Ack, Dst Endpt: 12, Src Endpt: 1 Frame Control Field: Ack (0x02) Destination Endpoint: 12 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 1 Counter: 197 No. Time Source Destination Protocol Length Info 42 103.270894 0x0000 0x5964 ZigBee HA 48 ZCL Groups: View Group, Seq: 129 Frame 42: 48 bytes on wire (384 bits), 48 bytes captured (384 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x2ed9, Src: 0x0000 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 121 Destination PAN: 0x1234 Destination: 0x2ed9 Source: 0x0000 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Network Layer Data, Dst: 0x5964, Src: 0x0000 Frame Control Field: 0x0248, Frame Type: Data, Discover Route: Enable, Security Data Destination: 0x5964 Source: 0x0000 Radius: 10 Sequence Number: 26 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 156409669 Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01) Key Sequence Number: 0 Message Integrity Code: 789acc29 [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 12, Src Endpt: 1 Frame Control Field: Data (0x00) Destination Endpoint: 12 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 1 Counter: 195 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x11) Sequence Number: 129 Command: View Group (0x01) Payload Group ID: 0x000b No. Time Source Destination Protocol Length Info 43 103.280802 0x0000 0x5964 ZigBee HA 48 ZCL Groups: View Group, Seq: 129 Frame 43: 48 bytes on wire (384 bits), 48 bytes captured (384 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x5964, Src: 0x2ed9 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 78 Destination PAN: 0x1234 Destination: 0x5964 Source: 0x2ed9 [Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d)] [Origin: 2] ZigBee Network Layer Data, Dst: 0x5964, Src: 0x0000 Frame Control Field: 0x0248, Frame Type: Data, Discover Route: Enable, Security Data Destination: 0x5964 Source: 0x0000 Radius: 9 Sequence Number: 26 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 57428956 Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d) Key Sequence Number: 0 Message Integrity Code: 536ed668 [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 12, Src Endpt: 1 Frame Control Field: Data (0x00) Destination Endpoint: 12 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 1 Counter: 195 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x11) Sequence Number: 129 Command: View Group (0x01) Payload Group ID: 0x000b No. Time Source Destination Protocol Length Info 44 103.286910 0x5964 0x0000 ZigBee HA 66 ZCL Groups: View Group Response, Seq: 129 Frame 44: 66 bytes on wire (528 bits), 66 bytes captured (528 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x2ed9, Src: 0x5964 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 209 Destination PAN: 0x1234 Destination: 0x2ed9 Source: 0x5964 [Extended Source: NordicSe_a9:ed:f6:8a:d2 (f4:ce:36:a9:ed:f6:8a:d2)] [Origin: 3] ZigBee Network Layer Data, Dst: 0x0000, Src: 0x5964 Frame Control Field: 0x1a48, Frame Type: Data, Discover Route: Enable, Security, Destination, Extended Source Data Destination: 0x0000 Source: 0x5964 Radius: 30 Sequence Number: 154 Destination: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01) Extended Source: NordicSe_a9:ed:f6:8a:d2 (f4:ce:36:a9:ed:f6:8a:d2) ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 154 Extended Source: NordicSe_a9:ed:f6:8a:d2 (f4:ce:36:a9:ed:f6:8a:d2) Key Sequence Number: 0 Message Integrity Code: 64fc7270 [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 1, Src Endpt: 12 Frame Control Field: Data (0x40) Destination Endpoint: 1 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 12 Counter: 198 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x19) Sequence Number: 129 Command: View Group Response (0x01) Payload, String: Group Status: Success (0x00) Group ID: 0x000b Length: 0 String: No. Time Source Destination Protocol Length Info 45 103.299614 0x5964 0x0000 ZigBee HA 66 ZCL Groups: View Group Response, Seq: 129 Frame 45: 66 bytes on wire (528 bits), 66 bytes captured (528 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x0000, Src: 0x2ed9 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 79 Destination PAN: 0x1234 Destination: 0x0000 Source: 0x2ed9 [Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d)] [Origin: 2] ZigBee Network Layer Data, Dst: 0x0000, Src: 0x5964 Frame Control Field: 0x1a48, Frame Type: Data, Discover Route: Enable, Security, Destination, Extended Source Data Destination: 0x0000 Source: 0x5964 Radius: 29 Sequence Number: 154 Destination: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01) Extended Source: NordicSe_a9:ed:f6:8a:d2 (f4:ce:36:a9:ed:f6:8a:d2) ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 57428957 Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d) Key Sequence Number: 0 Message Integrity Code: e695e8a6 [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 1, Src Endpt: 12 Frame Control Field: Data (0x40) Destination Endpoint: 1 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 12 Counter: 198 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x19) Sequence Number: 129 Command: View Group Response (0x01) Payload, String: Group Status: Success (0x00) Group ID: 0x000b Length: 0 String: No. Time Source Destination Protocol Length Info 46 103.306035 0x0000 0x5964 ZigBee 43 APS: Ack, Dst Endpt: 12, Src Endpt: 1 Frame 46: 43 bytes on wire (344 bits), 43 bytes captured (344 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x2ed9, Src: 0x0000 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 122 Destination PAN: 0x1234 Destination: 0x2ed9 Source: 0x0000 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Network Layer Data, Dst: 0x5964, Src: 0x0000 Frame Control Field: 0x0248, Frame Type: Data, Discover Route: Enable, Security Data Destination: 0x5964 Source: 0x0000 Radius: 10 Sequence Number: 27 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 156409670 Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01) Key Sequence Number: 0 Message Integrity Code: 9cf4f671 [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Ack, Dst Endpt: 12, Src Endpt: 1 Frame Control Field: Ack (0x02) Destination Endpoint: 12 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 1 Counter: 198 No. Time Source Destination Protocol Length Info 47 103.316378 0x0000 0x5964 ZigBee 43 APS: Ack, Dst Endpt: 12, Src Endpt: 1 Frame 47: 43 bytes on wire (344 bits), 43 bytes captured (344 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x5964, Src: 0x2ed9 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 80 Destination PAN: 0x1234 Destination: 0x5964 Source: 0x2ed9 [Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d)] [Origin: 2] ZigBee Network Layer Data, Dst: 0x5964, Src: 0x0000 Frame Control Field: 0x0248, Frame Type: Data, Discover Route: Enable, Security Data Destination: 0x5964 Source: 0x0000 Radius: 9 Sequence Number: 27 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 57428958 Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d) Key Sequence Number: 0 Message Integrity Code: bc8ddd93 [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Ack, Dst Endpt: 12, Src Endpt: 1 Frame Control Field: Ack (0x02) Destination Endpoint: 12 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 1 Counter: 198 No. Time Source Destination Protocol Length Info 48 115.682575 0x0000 0x5964 ZigBee HA 49 ZCL Groups: Get Group Membership, Seq: 145 Frame 48: 49 bytes on wire (392 bits), 49 bytes captured (392 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x2ed9, Src: 0x0000 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 195 Destination PAN: 0x1234 Destination: 0x2ed9 Source: 0x0000 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Network Layer Data, Dst: 0x5964, Src: 0x0000 Frame Control Field: 0x0248, Frame Type: Data, Discover Route: Enable, Security Data Destination: 0x5964 Source: 0x0000 Radius: 10 Sequence Number: 96 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 156409737 Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01) Key Sequence Number: 0 Message Integrity Code: b67f5aab [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 12, Src Endpt: 1 Frame Control Field: Data (0x00) Destination Endpoint: 12 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 1 Counter: 229 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x11) Sequence Number: 145 Command: Get Group Membership (0x02) Payload Group Count: 0 No. Time Source Destination Protocol Length Info 49 115.693498 0x0000 0x5964 ZigBee HA 49 ZCL Groups: Get Group Membership, Seq: 145 Frame 49: 49 bytes on wire (392 bits), 49 bytes captured (392 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x5964, Src: 0x2ed9 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 90 Destination PAN: 0x1234 Destination: 0x5964 Source: 0x2ed9 [Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d)] [Origin: 2] ZigBee Network Layer Data, Dst: 0x5964, Src: 0x0000 Frame Control Field: 0x0248, Frame Type: Data, Discover Route: Enable, Security Data Destination: 0x5964 Source: 0x0000 Radius: 9 Sequence Number: 96 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 57428968 Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d) Key Sequence Number: 0 Message Integrity Code: c7010db6 [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 12, Src Endpt: 1 Frame Control Field: Data (0x00) Destination Endpoint: 12 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 1 Counter: 229 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x11) Sequence Number: 145 Command: Get Group Membership (0x02) Payload Group Count: 0 No. Time Source Destination Protocol Length Info 50 115.698131 0x5964 0x0000 ZigBee HA 68 ZCL Groups: Get Group Membership Response, Seq: 145 Frame 50: 68 bytes on wire (544 bits), 68 bytes captured (544 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x2ed9, Src: 0x5964 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 210 Destination PAN: 0x1234 Destination: 0x2ed9 Source: 0x5964 [Extended Source: NordicSe_a9:ed:f6:8a:d2 (f4:ce:36:a9:ed:f6:8a:d2)] [Origin: 3] ZigBee Network Layer Data, Dst: 0x0000, Src: 0x5964 Frame Control Field: 0x1a48, Frame Type: Data, Discover Route: Enable, Security, Destination, Extended Source Data Destination: 0x0000 Source: 0x5964 Radius: 30 Sequence Number: 155 Destination: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01) Extended Source: NordicSe_a9:ed:f6:8a:d2 (f4:ce:36:a9:ed:f6:8a:d2) ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 155 Extended Source: NordicSe_a9:ed:f6:8a:d2 (f4:ce:36:a9:ed:f6:8a:d2) Key Sequence Number: 0 Message Integrity Code: 9a1aeb0a [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 1, Src Endpt: 12 Frame Control Field: Data (0x40) Destination Endpoint: 1 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 12 Counter: 199 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x19) Sequence Number: 145 Command: Get Group Membership Response (0x02) Payload Group Capacity: 6 Group Count: 2 Group List Group ID: 0x000a Group ID: 0x000b No. Time Source Destination Protocol Length Info 51 115.711424 0x5964 0x0000 ZigBee HA 68 ZCL Groups: Get Group Membership Response, Seq: 145 Frame 51: 68 bytes on wire (544 bits), 68 bytes captured (544 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x0000, Src: 0x2ed9 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 91 Destination PAN: 0x1234 Destination: 0x0000 Source: 0x2ed9 [Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d)] [Origin: 2] ZigBee Network Layer Data, Dst: 0x0000, Src: 0x5964 Frame Control Field: 0x1a48, Frame Type: Data, Discover Route: Enable, Security, Destination, Extended Source Data Destination: 0x0000 Source: 0x5964 Radius: 29 Sequence Number: 155 Destination: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01) Extended Source: NordicSe_a9:ed:f6:8a:d2 (f4:ce:36:a9:ed:f6:8a:d2) ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 57428969 Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d) Key Sequence Number: 0 Message Integrity Code: d7513b6c [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 1, Src Endpt: 12 Frame Control Field: Data (0x40) Destination Endpoint: 1 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 12 Counter: 199 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x19) Sequence Number: 145 Command: Get Group Membership Response (0x02) Payload Group Capacity: 6 Group Count: 2 Group List Group ID: 0x000a Group ID: 0x000b No. Time Source Destination Protocol Length Info 52 115.718985 0x0000 0x5964 ZigBee 43 APS: Ack, Dst Endpt: 12, Src Endpt: 1 Frame 52: 43 bytes on wire (344 bits), 43 bytes captured (344 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x2ed9, Src: 0x0000 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 196 Destination PAN: 0x1234 Destination: 0x2ed9 Source: 0x0000 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Network Layer Data, Dst: 0x5964, Src: 0x0000 Frame Control Field: 0x0248, Frame Type: Data, Discover Route: Enable, Security Data Destination: 0x5964 Source: 0x0000 Radius: 10 Sequence Number: 97 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 156409738 Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01) Key Sequence Number: 0 Message Integrity Code: 0a3023af [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Ack, Dst Endpt: 12, Src Endpt: 1 Frame Control Field: Ack (0x02) Destination Endpoint: 12 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 1 Counter: 199 No. Time Source Destination Protocol Length Info 53 115.729319 0x0000 0x5964 ZigBee 43 APS: Ack, Dst Endpt: 12, Src Endpt: 1 Frame 53: 43 bytes on wire (344 bits), 43 bytes captured (344 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x5964, Src: 0x2ed9 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 92 Destination PAN: 0x1234 Destination: 0x5964 Source: 0x2ed9 [Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d)] [Origin: 2] ZigBee Network Layer Data, Dst: 0x5964, Src: 0x0000 Frame Control Field: 0x0248, Frame Type: Data, Discover Route: Enable, Security Data Destination: 0x5964 Source: 0x0000 Radius: 9 Sequence Number: 97 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 57428970 Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d) Key Sequence Number: 0 Message Integrity Code: e4577c91 [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Ack, Dst Endpt: 12, Src Endpt: 1 Frame Control Field: Ack (0x02) Destination Endpoint: 12 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 1 Counter: 199 No. Time Source Destination Protocol Length Info 54 145.302902 0x0000 0x5964 ZigBee HA 48 ZCL Groups: Remove a Group, Seq: 170 Frame 54: 48 bytes on wire (384 bits), 48 bytes captured (384 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x2ed9, Src: 0x0000 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 105 Destination PAN: 0x1234 Destination: 0x2ed9 Source: 0x0000 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Network Layer Data, Dst: 0x5964, Src: 0x0000 Frame Control Field: 0x0248, Frame Type: Data, Discover Route: Enable, Security Data Destination: 0x5964 Source: 0x0000 Radius: 10 Sequence Number: 1 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 156409899 Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01) Key Sequence Number: 0 Message Integrity Code: dab2b38f [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 12, Src Endpt: 1 Frame Control Field: Data (0x00) Destination Endpoint: 12 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 1 Counter: 52 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x11) Sequence Number: 170 Command: Remove a Group (0x03) Payload Group ID: 0x000a No. Time Source Destination Protocol Length Info 55 145.307671 0x0000 0x5964 ZigBee HA 48 ZCL Groups: Remove a Group, Seq: 170 Frame 55: 48 bytes on wire (384 bits), 48 bytes captured (384 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x2ed9, Src: 0x0000 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 105 Destination PAN: 0x1234 Destination: 0x2ed9 Source: 0x0000 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Network Layer Data, Dst: 0x5964, Src: 0x0000 Frame Control Field: 0x0248, Frame Type: Data, Discover Route: Enable, Security Data Destination: 0x5964 Source: 0x0000 Radius: 10 Sequence Number: 1 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 156409899 Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01) Key Sequence Number: 0 Message Integrity Code: dab2b38f [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 12, Src Endpt: 1 Frame Control Field: Data (0x00) Destination Endpoint: 12 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 1 Counter: 52 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x11) Sequence Number: 170 Command: Remove a Group (0x03) Payload Group ID: 0x000a No. Time Source Destination Protocol Length Info 56 145.315131 0x0000 0x5964 ZigBee HA 48 ZCL Groups: Remove a Group, Seq: 170 Frame 56: 48 bytes on wire (384 bits), 48 bytes captured (384 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x5964, Src: 0x2ed9 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 144 Destination PAN: 0x1234 Destination: 0x5964 Source: 0x2ed9 [Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d)] [Origin: 2] ZigBee Network Layer Data, Dst: 0x5964, Src: 0x0000 Frame Control Field: 0x0248, Frame Type: Data, Discover Route: Enable, Security Data Destination: 0x5964 Source: 0x0000 Radius: 9 Sequence Number: 1 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 57429022 Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d) Key Sequence Number: 0 Message Integrity Code: 9d8f437b [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 12, Src Endpt: 1 Frame Control Field: Data (0x00) Destination Endpoint: 12 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 1 Counter: 52 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x11) Sequence Number: 170 Command: Remove a Group (0x03) Payload Group ID: 0x000a No. Time Source Destination Protocol Length Info 57 145.320926 0x5964 0x0000 ZigBee HA 65 ZCL Groups: Remove a Group Response, Seq: 170 Frame 57: 65 bytes on wire (520 bits), 65 bytes captured (520 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x2ed9, Src: 0x5964 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 222 Destination PAN: 0x1234 Destination: 0x2ed9 Source: 0x5964 [Extended Source: NordicSe_a9:ed:f6:8a:d2 (f4:ce:36:a9:ed:f6:8a:d2)] [Origin: 3] ZigBee Network Layer Data, Dst: 0x0000, Src: 0x5964 Frame Control Field: 0x1a48, Frame Type: Data, Discover Route: Enable, Security, Destination, Extended Source Data Destination: 0x0000 Source: 0x5964 Radius: 30 Sequence Number: 167 Destination: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01) Extended Source: NordicSe_a9:ed:f6:8a:d2 (f4:ce:36:a9:ed:f6:8a:d2) ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 167 Extended Source: NordicSe_a9:ed:f6:8a:d2 (f4:ce:36:a9:ed:f6:8a:d2) Key Sequence Number: 0 Message Integrity Code: 24b5d397 [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 1, Src Endpt: 12 Frame Control Field: Data (0x40) Destination Endpoint: 1 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 12 Counter: 211 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x19) Sequence Number: 170 Command: Remove a Group Response (0x03) Payload Group Status: Not Found (0x8b) Group ID: 0x000a No. Time Source Destination Protocol Length Info 58 145.324575 0x0000 0x5964 ZigBee HA 48 ZCL Groups: Remove a Group, Seq: 170 Frame 58: 48 bytes on wire (384 bits), 48 bytes captured (384 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x5964, Src: 0x2ed9 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 145 Destination PAN: 0x1234 Destination: 0x5964 Source: 0x2ed9 [Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d)] [Origin: 2] ZigBee Network Layer Data, Dst: 0x5964, Src: 0x0000 Frame Control Field: 0x0248, Frame Type: Data, Discover Route: Enable, Security Data Destination: 0x5964 Source: 0x0000 Radius: 9 Sequence Number: 1 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 57429023 Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d) Key Sequence Number: 0 Message Integrity Code: e8a02102 [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 12, Src Endpt: 1 Frame Control Field: Data (0x00) Destination Endpoint: 12 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 1 Counter: 52 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x11) Sequence Number: 170 Command: Remove a Group (0x03) Payload Group ID: 0x000a No. Time Source Destination Protocol Length Info 59 148.307644 0x5964 0x0000 ZigBee HA 65 ZCL Groups: Remove a Group Response, Seq: 170 Frame 59: 65 bytes on wire (520 bits), 65 bytes captured (520 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x2ed9, Src: 0x5964 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 223 Destination PAN: 0x1234 Destination: 0x2ed9 Source: 0x5964 [Extended Source: NordicSe_a9:ed:f6:8a:d2 (f4:ce:36:a9:ed:f6:8a:d2)] [Origin: 3] ZigBee Network Layer Data, Dst: 0x0000, Src: 0x5964 Frame Control Field: 0x1a48, Frame Type: Data, Discover Route: Enable, Security, Destination, Extended Source Data Destination: 0x0000 Source: 0x5964 Radius: 30 Sequence Number: 168 Destination: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01) Extended Source: NordicSe_a9:ed:f6:8a:d2 (f4:ce:36:a9:ed:f6:8a:d2) ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 168 Extended Source: NordicSe_a9:ed:f6:8a:d2 (f4:ce:36:a9:ed:f6:8a:d2) Key Sequence Number: 0 Message Integrity Code: 487684e7 [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 1, Src Endpt: 12 Frame Control Field: Data (0x40) Destination Endpoint: 1 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 12 Counter: 211 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x19) Sequence Number: 170 Command: Remove a Group Response (0x03) Payload Group Status: Not Found (0x8b) Group ID: 0x000a No. Time Source Destination Protocol Length Info 60 148.335495 0x5964 0x0000 ZigBee HA 65 ZCL Groups: Remove a Group Response, Seq: 170 Frame 60: 65 bytes on wire (520 bits), 65 bytes captured (520 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x0000, Src: 0x2ed9 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 146 Destination PAN: 0x1234 Destination: 0x0000 Source: 0x2ed9 [Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d)] [Origin: 2] ZigBee Network Layer Data, Dst: 0x0000, Src: 0x5964 Frame Control Field: 0x1a48, Frame Type: Data, Discover Route: Enable, Security, Destination, Extended Source Data Destination: 0x0000 Source: 0x5964 Radius: 29 Sequence Number: 168 Destination: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01) Extended Source: NordicSe_a9:ed:f6:8a:d2 (f4:ce:36:a9:ed:f6:8a:d2) ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 57429024 Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d) Key Sequence Number: 0 Message Integrity Code: dea38350 [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 1, Src Endpt: 12 Frame Control Field: Data (0x40) Destination Endpoint: 1 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 12 Counter: 211 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x19) Sequence Number: 170 Command: Remove a Group Response (0x03) Payload Group Status: Not Found (0x8b) Group ID: 0x000a No. Time Source Destination Protocol Length Info 61 148.342651 0x0000 0x5964 ZigBee 43 APS: Ack, Dst Endpt: 12, Src Endpt: 1 Frame 61: 43 bytes on wire (344 bits), 43 bytes captured (344 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x2ed9, Src: 0x0000 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 128 Destination PAN: 0x1234 Destination: 0x2ed9 Source: 0x0000 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Network Layer Data, Dst: 0x5964, Src: 0x0000 Frame Control Field: 0x0248, Frame Type: Data, Discover Route: Enable, Security Data Destination: 0x5964 Source: 0x0000 Radius: 10 Sequence Number: 24 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 156409922 Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01) Key Sequence Number: 0 Message Integrity Code: d535b436 [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Ack, Dst Endpt: 12, Src Endpt: 1 Frame Control Field: Ack (0x02) Destination Endpoint: 12 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 1 Counter: 211 No. Time Source Destination Protocol Length Info 62 148.353634 0x0000 0x5964 ZigBee 43 APS: Ack, Dst Endpt: 12, Src Endpt: 1 Frame 62: 43 bytes on wire (344 bits), 43 bytes captured (344 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x5964, Src: 0x2ed9 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 147 Destination PAN: 0x1234 Destination: 0x5964 Source: 0x2ed9 [Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d)] [Origin: 2] ZigBee Network Layer Data, Dst: 0x5964, Src: 0x0000 Frame Control Field: 0x0248, Frame Type: Data, Discover Route: Enable, Security Data Destination: 0x5964 Source: 0x0000 Radius: 9 Sequence Number: 24 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 57429025 Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d) Key Sequence Number: 0 Message Integrity Code: 8cc54991 [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Ack, Dst Endpt: 12, Src Endpt: 1 Frame Control Field: Ack (0x02) Destination Endpoint: 12 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 1 Counter: 211 No. Time Source Destination Protocol Length Info 63 153.618844 0x0000 0x5964 ZigBee HA 48 ZCL Groups: Remove a Group, Seq: 183 Frame 63: 48 bytes on wire (384 bits), 48 bytes captured (384 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x2ed9, Src: 0x0000 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 171 Destination PAN: 0x1234 Destination: 0x2ed9 Source: 0x0000 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Network Layer Data, Dst: 0x5964, Src: 0x0000 Frame Control Field: 0x0248, Frame Type: Data, Discover Route: Enable, Security Data Destination: 0x5964 Source: 0x0000 Radius: 10 Sequence Number: 59 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 156409959 Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01) Key Sequence Number: 0 Message Integrity Code: 70b829e5 [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 12, Src Endpt: 1 Frame Control Field: Data (0x00) Destination Endpoint: 12 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 1 Counter: 82 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x11) Sequence Number: 183 Command: Remove a Group (0x03) Payload Group ID: 0x000b No. Time Source Destination Protocol Length Info 64 153.629087 0x0000 0x5964 ZigBee HA 48 ZCL Groups: Remove a Group, Seq: 183 Frame 64: 48 bytes on wire (384 bits), 48 bytes captured (384 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x5964, Src: 0x2ed9 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 152 Destination PAN: 0x1234 Destination: 0x5964 Source: 0x2ed9 [Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d)] [Origin: 2] ZigBee Network Layer Data, Dst: 0x5964, Src: 0x0000 Frame Control Field: 0x0248, Frame Type: Data, Discover Route: Enable, Security Data Destination: 0x5964 Source: 0x0000 Radius: 9 Sequence Number: 59 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 57429030 Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d) Key Sequence Number: 0 Message Integrity Code: 35e9616e [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 12, Src Endpt: 1 Frame Control Field: Data (0x00) Destination Endpoint: 12 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 1 Counter: 82 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x11) Sequence Number: 183 Command: Remove a Group (0x03) Payload Group ID: 0x000b No. Time Source Destination Protocol Length Info 65 153.634596 0x5964 0x0000 ZigBee HA 65 ZCL Groups: Remove a Group Response, Seq: 183 Frame 65: 65 bytes on wire (520 bits), 65 bytes captured (520 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x2ed9, Src: 0x5964 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 224 Destination PAN: 0x1234 Destination: 0x2ed9 Source: 0x5964 [Extended Source: NordicSe_a9:ed:f6:8a:d2 (f4:ce:36:a9:ed:f6:8a:d2)] [Origin: 3] ZigBee Network Layer Data, Dst: 0x0000, Src: 0x5964 Frame Control Field: 0x1a48, Frame Type: Data, Discover Route: Enable, Security, Destination, Extended Source Data Destination: 0x0000 Source: 0x5964 Radius: 30 Sequence Number: 169 Destination: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01) Extended Source: NordicSe_a9:ed:f6:8a:d2 (f4:ce:36:a9:ed:f6:8a:d2) ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 169 Extended Source: NordicSe_a9:ed:f6:8a:d2 (f4:ce:36:a9:ed:f6:8a:d2) Key Sequence Number: 0 Message Integrity Code: d89128a7 [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 1, Src Endpt: 12 Frame Control Field: Data (0x40) Destination Endpoint: 1 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 12 Counter: 212 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x19) Sequence Number: 183 Command: Remove a Group Response (0x03) Payload Group Status: Not Found (0x8b) Group ID: 0x000b No. Time Source Destination Protocol Length Info 66 153.648209 0x5964 0x0000 ZigBee HA 65 ZCL Groups: Remove a Group Response, Seq: 183 Frame 66: 65 bytes on wire (520 bits), 65 bytes captured (520 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x0000, Src: 0x2ed9 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 153 Destination PAN: 0x1234 Destination: 0x0000 Source: 0x2ed9 [Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d)] [Origin: 2] ZigBee Network Layer Data, Dst: 0x0000, Src: 0x5964 Frame Control Field: 0x1a48, Frame Type: Data, Discover Route: Enable, Security, Destination, Extended Source Data Destination: 0x0000 Source: 0x5964 Radius: 29 Sequence Number: 169 Destination: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01) Extended Source: NordicSe_a9:ed:f6:8a:d2 (f4:ce:36:a9:ed:f6:8a:d2) ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 57429031 Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d) Key Sequence Number: 0 Message Integrity Code: 1eea8a89 [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 1, Src Endpt: 12 Frame Control Field: Data (0x40) Destination Endpoint: 1 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 12 Counter: 212 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x19) Sequence Number: 183 Command: Remove a Group Response (0x03) Payload Group Status: Not Found (0x8b) Group ID: 0x000b No. Time Source Destination Protocol Length Info 67 153.655553 0x0000 0x5964 ZigBee 43 APS: Ack, Dst Endpt: 12, Src Endpt: 1 Frame 67: 43 bytes on wire (344 bits), 43 bytes captured (344 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x2ed9, Src: 0x0000 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 172 Destination PAN: 0x1234 Destination: 0x2ed9 Source: 0x0000 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Network Layer Data, Dst: 0x5964, Src: 0x0000 Frame Control Field: 0x0248, Frame Type: Data, Discover Route: Enable, Security Data Destination: 0x5964 Source: 0x0000 Radius: 10 Sequence Number: 60 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 156409960 Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01) Key Sequence Number: 0 Message Integrity Code: 6bb89e6c [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Ack, Dst Endpt: 12, Src Endpt: 1 Frame Control Field: Ack (0x02) Destination Endpoint: 12 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 1 Counter: 212 No. Time Source Destination Protocol Length Info 68 153.665215 0x0000 0x5964 ZigBee 43 APS: Ack, Dst Endpt: 12, Src Endpt: 1 Frame 68: 43 bytes on wire (344 bits), 43 bytes captured (344 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x5964, Src: 0x2ed9 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 154 Destination PAN: 0x1234 Destination: 0x5964 Source: 0x2ed9 [Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d)] [Origin: 2] ZigBee Network Layer Data, Dst: 0x5964, Src: 0x0000 Frame Control Field: 0x0248, Frame Type: Data, Discover Route: Enable, Security Data Destination: 0x5964 Source: 0x0000 Radius: 9 Sequence Number: 60 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 57429032 Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d) Key Sequence Number: 0 Message Integrity Code: 30985ab1 [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Ack, Dst Endpt: 12, Src Endpt: 1 Frame Control Field: Ack (0x02) Destination Endpoint: 12 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 1 Counter: 212 No. Time Source Destination Protocol Length Info 69 164.686563 0x0000 0x5964 ZigBee HA 49 ZCL Groups: Get Group Membership, Seq: 191 Frame 69: 49 bytes on wire (392 bits), 49 bytes captured (392 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x2ed9, Src: 0x0000 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 247 Destination PAN: 0x1234 Destination: 0x2ed9 Source: 0x0000 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Network Layer Data, Dst: 0x5964, Src: 0x0000 Frame Control Field: 0x0248, Frame Type: Data, Discover Route: Enable, Security Data Destination: 0x5964 Source: 0x0000 Radius: 10 Sequence Number: 128 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 156410031 Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01) Key Sequence Number: 0 Message Integrity Code: 47b4e4c7 [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 10, Src Endpt: 1 Frame Control Field: Data (0x00) Destination Endpoint: 10 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 1 Counter: 116 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x11) Sequence Number: 191 Command: Get Group Membership (0x02) Payload Group Count: 0 No. Time Source Destination Protocol Length Info 70 164.698008 0x0000 0x5964 ZigBee HA 49 ZCL Groups: Get Group Membership, Seq: 191 Frame 70: 49 bytes on wire (392 bits), 49 bytes captured (392 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x5964, Src: 0x2ed9 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 190 Destination PAN: 0x1234 Destination: 0x5964 Source: 0x2ed9 [Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d)] [Origin: 2] ZigBee Network Layer Data, Dst: 0x5964, Src: 0x0000 Frame Control Field: 0x0248, Frame Type: Data, Discover Route: Enable, Security Data Destination: 0x5964 Source: 0x0000 Radius: 9 Sequence Number: 128 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 57429068 Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d) Key Sequence Number: 0 Message Integrity Code: ff44390c [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 10, Src Endpt: 1 Frame Control Field: Data (0x00) Destination Endpoint: 10 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 1 Counter: 116 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x11) Sequence Number: 191 Command: Get Group Membership (0x02) Payload Group Count: 0 No. Time Source Destination Protocol Length Info 71 164.703299 0x5964 0x0000 ZigBee HA 68 ZCL Groups: Get Group Membership Response, Seq: 191 Frame 71: 68 bytes on wire (544 bits), 68 bytes captured (544 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x2ed9, Src: 0x5964 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 236 Destination PAN: 0x1234 Destination: 0x2ed9 Source: 0x5964 [Extended Source: NordicSe_a9:ed:f6:8a:d2 (f4:ce:36:a9:ed:f6:8a:d2)] [Origin: 3] ZigBee Network Layer Data, Dst: 0x0000, Src: 0x5964 Frame Control Field: 0x1a48, Frame Type: Data, Discover Route: Enable, Security, Destination, Extended Source Data Destination: 0x0000 Source: 0x5964 Radius: 30 Sequence Number: 181 Destination: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01) Extended Source: NordicSe_a9:ed:f6:8a:d2 (f4:ce:36:a9:ed:f6:8a:d2) ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 181 Extended Source: NordicSe_a9:ed:f6:8a:d2 (f4:ce:36:a9:ed:f6:8a:d2) Key Sequence Number: 0 Message Integrity Code: 99b12ed5 [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 1, Src Endpt: 10 Frame Control Field: Data (0x40) Destination Endpoint: 1 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 10 Counter: 224 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x19) Sequence Number: 191 Command: Get Group Membership Response (0x02) Payload Group Capacity: 6 Group Count: 2 Group List Group ID: 0x000a Group ID: 0x000b No. Time Source Destination Protocol Length Info 72 164.715964 0x5964 0x0000 ZigBee HA 68 ZCL Groups: Get Group Membership Response, Seq: 191 Frame 72: 68 bytes on wire (544 bits), 68 bytes captured (544 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x0000, Src: 0x2ed9 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 191 Destination PAN: 0x1234 Destination: 0x0000 Source: 0x2ed9 [Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d)] [Origin: 2] ZigBee Network Layer Data, Dst: 0x0000, Src: 0x5964 Frame Control Field: 0x1a48, Frame Type: Data, Discover Route: Enable, Security, Destination, Extended Source Data Destination: 0x0000 Source: 0x5964 Radius: 29 Sequence Number: 181 Destination: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01) Extended Source: NordicSe_a9:ed:f6:8a:d2 (f4:ce:36:a9:ed:f6:8a:d2) ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 57429069 Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d) Key Sequence Number: 0 Message Integrity Code: 256ca002 [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 1, Src Endpt: 10 Frame Control Field: Data (0x40) Destination Endpoint: 1 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 10 Counter: 224 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x19) Sequence Number: 191 Command: Get Group Membership Response (0x02) Payload Group Capacity: 6 Group Count: 2 Group List Group ID: 0x000a Group ID: 0x000b No. Time Source Destination Protocol Length Info 73 164.741132 0x5964 0x0000 ZigBee HA 68 ZCL Groups: Get Group Membership Response, Seq: 191 Frame 73: 68 bytes on wire (544 bits), 68 bytes captured (544 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x0000, Src: 0x2ed9 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 191 Destination PAN: 0x1234 Destination: 0x0000 Source: 0x2ed9 [Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d)] [Origin: 2] ZigBee Network Layer Data, Dst: 0x0000, Src: 0x5964 Frame Control Field: 0x1a48, Frame Type: Data, Discover Route: Enable, Security, Destination, Extended Source Data Destination: 0x0000 Source: 0x5964 Radius: 29 Sequence Number: 181 Destination: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01) Extended Source: NordicSe_a9:ed:f6:8a:d2 (f4:ce:36:a9:ed:f6:8a:d2) ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 57429069 Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d) Key Sequence Number: 0 Message Integrity Code: 256ca002 [Key: deadbeef] [Key Label: ] ZigBee Application Support Layer Data, Dst Endpt: 1, Src Endpt: 10 Frame Control Field: Data (0x40) Destination Endpoint: 1 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 10 Counter: 224 ZigBee Cluster Library Frame Frame Control Field: Cluster-specific (0x19) Sequence Number: 191 Command: Get Group Membership Response (0x02) Payload Group Capacity: 6 Group Count: 2 Group List Group ID: 0x000a Group ID: 0x000b No. Time Source Destination Protocol Length Info 74 164.759042 0x0000 0x5964 ZigBee 43 APS: Ack, Dst Endpt: 10, Src Endpt: 1 Frame 74: 43 bytes on wire (344 bits), 43 bytes captured (344 bits) on interface /var/folders/nl/t85ds9bd7m1bb386f3cjjz0c0000gp/T//wireshark_extcap_-dev-cu.usbmodemC820F39C08021_20210415134909_MAdAFb, id 0 IEEE 802.15.4 Data, Dst: 0x5964, Src: 0x2ed9 Frame Control Field: 0x8861, Frame Type: Data, Acknowledge Request, PAN ID Compression, Destination Addressing Mode: Short/16-bit, Frame Version: IEEE Std 802.15.4-2003, Source Addressing Mode: Short/16-bit Sequence Number: 192 Destination PAN: 0x1234 Destination: 0x5964 Source: 0x2ed9 [Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d)] [Origin: 2] ZigBee Network Layer Data, Dst: 0x5964, Src: 0x0000 Frame Control Field: 0x0248, Frame Type: Data, Discover Route: Enable, Security Data Destination: 0x5964 Source: 0x0000 Radius: 9 Sequence Number: 130 [Extended Source: 00:00:00_00:00:00:00:01 (00:00:00:00:00:00:00:01)] [Origin: 1] ZigBee Security Header Security Control Field: 0x28, Key Id: Network Key, Extended Nonce Frame Counter: 57429070 Extended Source: Atmel_1c:a0:f6:31:6d (00:04:25:1c:a0:f6:31:6d) Key Sequence Number: 0 Message Integrity Code: ba657338 [Key] [Key Label: ] ZigBee Application Support Layer Ack, Dst Endpt: 10, Src Endpt: 1 Frame Control Field: Ack (0x02) Destination Endpoint: 10 Cluster: Groups (0x0004) Profile: Home Automation (0x0104) Source Endpoint: 1 Counter: 224