No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 44 83.999 ff:ff:c0:18:01:83 LE 1M LE LL 20 639 0 ADV_IND Frame 44: 46 bytes on wire (368 bits), 46 bytes captured (368 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0x8e89bed6 Packet Header: 0x1400 (PDU Type: ADV_IND, ChSel: #1, TxAdd: Public) .... 0000 = PDU Type: ADV_IND (0x0) ...0 .... = RFU: 0 ..0. .... = Channel Selection Algorithm: #1 .0.. .... = Tx Address: Public 0... .... = Reserved: False Length: 20 Advertising Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83) Advertising Data CRC: 0xdd16e2 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 45 84.001 75:f9:6a:24:6f:be LE 1M LE LL 34 150 0 CONNECT_REQ Frame 45: 60 bytes on wire (480 bits), 60 bytes captured (480 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0x8e89bed6 Packet Header: 0x2245 (PDU Type: CONNECT_REQ, ChSel: #1, TxAdd: Random, RxAdd: Public) .... 0101 = PDU Type: CONNECT_REQ (0x5) ...0 .... = RFU: 0 ..0. .... = Channel Selection Algorithm: #1 .1.. .... = Tx Address: Random 0... .... = Rx Address: Public Length: 34 Initator Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be) Advertising Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83) Link Layer Data Access Address: 0xeeafb3c9 CRC Init: 0x6c8783 Window Size: 2 (2.5 msec) Window Offset: 18 (22.5 msec) Interval: 36 (45 msec) Latency: 0 Timeout: 500 (5000 msec) Channel Map: 00feffff1f .... ...0 = RF Channel 1 (2404 MHz - Data - 0): False .... ..0. = RF Channel 2 (2406 MHz - Data - 1): False .... .0.. = RF Channel 3 (2408 MHz - Data - 2): False .... 0... = RF Channel 4 (2410 MHz - Data - 3): False ...0 .... = RF Channel 5 (2412 MHz - Data - 4): False ..0. .... = RF Channel 6 (2414 MHz - Data - 5): False .0.. .... = RF Channel 7 (2416 MHz - Data - 6): False 0... .... = RF Channel 8 (2418 MHz - Data - 7): False .... ...0 = RF Channel 9 (2420 MHz - Data - 8): False .... ..1. = RF Channel 10 (2422 MHz - Data - 9): True .... .1.. = RF Channel 11 (2424 MHz - Data - 10): True .... 1... = RF Channel 13 (2428 MHz - Data - 11): True ...1 .... = RF Channel 14 (2430 MHz - Data - 12): True ..1. .... = RF Channel 15 (2432 MHz - Data - 13): True .1.. .... = RF Channel 16 (2434 MHz - Data - 14): True 1... .... = RF Channel 17 (2436 MHz - Data - 15): True .... ...1 = RF Channel 18 (2438 MHz - Data - 16): True .... ..1. = RF Channel 19 (2440 MHz - Data - 17): True .... .1.. = RF Channel 20 (2442 MHz - Data - 18): True .... 1... = RF Channel 21 (2444 MHz - Data - 19): True ...1 .... = RF Channel 22 (2446 MHz - Data - 20): True ..1. .... = RF Channel 23 (2448 MHz - Data - 21): True .1.. .... = RF Channel 24 (2450 MHz - Data - 22): True 1... .... = RF Channel 25 (2452 MHz - Data - 23): True .... ...1 = RF Channel 26 (2454 MHz - Data - 24): True .... ..1. = RF Channel 27 (2456 MHz - Data - 25): True .... .1.. = RF Channel 28 (2458 MHz - Data - 26): True .... 1... = RF Channel 29 (2460 MHz - Data - 27): True ...1 .... = RF Channel 30 (2462 MHz - Data - 28): True ..1. .... = RF Channel 31 (2464 MHz - Data - 29): True .1.. .... = RF Channel 32 (2466 MHz - Data - 30): True 1... .... = RF Channel 33 (2468 MHz - Data - 31): True .... ...1 = RF Channel 34 (2470 MHz - Data - 32): True .... ..1. = RF Channel 35 (2472 MHz - Data - 33): True .... .1.. = RF Channel 36 (2474 MHz - Data - 34): True .... 1... = RF Channel 37 (2476 MHz - Data - 35): True ...1 .... = RF Channel 38 (2478 MHz - Data - 36): True ..0. .... = RF Channel 0 (2402 MHz - Reserved for Advertising - 37): False .0.. .... = RF Channel 12 (2426 MHz - Reserved for Advertising - 38): False 0... .... = RF Channel 39 (2480 MHz - Reserved for Advertising - 39): False ...0 1001 = Hop: 9 000. .... = Sleep Clock Accuracy: 251 ppm to 500 ppm (0) CRC: 0x439674 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 46 84.001 Master_0xeeafb3c9 LE 1M LE LL 9 24696 0 0 False 0 Control Opcode: LL_FEATURE_REQ Frame 46: 35 bytes on wire (280 bits), 35 bytes captured (280 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0903 Control Opcode: LL_FEATURE_REQ (0x08) Feature Set: 0x00000000000005ff CRC: 0xd93b14 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 47 84.001 Slave_0xeeafb3c9 LE 1M LE LL 0 152 0 1 False 0 Empty PDU Frame 47: 26 bytes on wire (208 bits), 26 bytes captured (208 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0005 CRC: 0x10c6b7 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 48 84.103 Master_0xeeafb3c9 LE 1M LE LL 0 44616 1 1 False 1 Empty PDU Frame 48: 26 bytes on wire (208 bits), 26 bytes captured (208 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x000d CRC: 0x7576b7 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 49 84.103 Slave_0xeeafb3c9 LE 1M LE LL 9 151 1 0 False 1 Control Opcode: LL_FEATURE_RSP Frame 49: 35 bytes on wire (280 bits), 35 bytes captured (280 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x090b Control Opcode: LL_FEATURE_RSP (0x09) Feature Set: 0x0000000000000001 CRC: 0xa65f37 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 50 84.105 Master_0xeeafb3c9 LE 1M LE LL 6 44616 0 0 False 2 Control Opcode: LL_VERSION_IND Frame 50: 32 bytes on wire (256 bits), 32 bytes captured (256 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0603 Control Opcode: LL_VERSION_IND (0x0c) Version Number: 5.0 (0x09) Company Id: Qualcomm (0x1d) Subversion Number: 0x02be CRC: 0x04f478 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 51 84.105 Slave_0xeeafb3c9 LE 1M LE LL 0 152 0 1 False 2 Empty PDU Frame 51: 26 bytes on wire (208 bits), 26 bytes captured (208 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0005 CRC: 0x10c6b7 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 52 84.206 Master_0xeeafb3c9 LE 1M LE LL 0 44640 1 1 False 3 Empty PDU Frame 52: 26 bytes on wire (208 bits), 26 bytes captured (208 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x000d CRC: 0x7576b7 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 53 84.208 Slave_0xeeafb3c9 LE 1M LE LL 6 152 1 0 False 3 Control Opcode: LL_VERSION_IND Frame 53: 32 bytes on wire (256 bits), 32 bytes captured (256 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x060b Control Opcode: LL_VERSION_IND (0x0c) Version Number: 4.0 (0x06) Company Id: Telink Semiconductor Co. Ltd (0x211) Subversion Number: 0x4103 CRC: 0x67db9c No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 54 84.208 Master_0xeeafb3c9 LE 1M LE LL 12 44640 0 0 True 4 Control Opcode: LL_CONNECTION_UPDATE_REQ Frame 54: 38 bytes on wire (304 bits), 38 bytes captured (304 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0c13 Control Opcode: LL_CONNECTION_UPDATE_REQ (0x00) Window Size: 1 Window Offset: 0 Interval: 6 Latency: 0 Timeout: 500 Instant: 13 CRC: 0x4a27c7 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 55 84.209 Slave_0xeeafb3c9 LE 1M LE LL 0 152 0 1 False 4 Empty PDU Frame 55: 26 bytes on wire (208 bits), 26 bytes captured (208 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0005 CRC: 0x10c6b7 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 56 84.209 Master_0xeeafb3c9 LE 1M ATT 11 150 1 1 False 4 Sent Read By Group Type Request, GATT Primary Service Declaration, Handles: 0x0001..0xffff Frame 56: 37 bytes on wire (296 bits), 37 bytes captured (296 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0b0e [L2CAP Index: 0] CRC: 0x0b4e59 Bluetooth L2CAP Protocol Bluetooth Attribute Protocol Opcode: Read By Group Type Request (0x10) Starting Handle: 0x0001 Ending Handle: 0xffff UUID: GATT Primary Service Declaration (0x2800) No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 57 84.210 Master_0xeeafb3c9 LE 1M ATT 11 44274 1 1 False 5 Sent Read By Group Type Request, GATT Primary Service Declaration, Handles: 0x0001..0xffff Frame 57: 37 bytes on wire (296 bits), 37 bytes captured (296 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0b0e [L2CAP Index: 1] CRC: 0x0b4e59 Bluetooth L2CAP Protocol Bluetooth Attribute Protocol Opcode: Read By Group Type Request (0x10) Starting Handle: 0x0001 Ending Handle: 0xffff UUID: GATT Primary Service Declaration (0x2800) [Response in Frame: 60] No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 58 84.210 Slave_0xeeafb3c9 LE 1M LE LL 0 151 1 0 False 5 Empty PDU Frame 58: 26 bytes on wire (208 bits), 26 bytes captured (208 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0009 CRC: 0xbe16b7 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 59 84.311 Master_0xeeafb3c9 LE 1M LE LL 0 44601 0 0 False 6 Empty PDU Frame 59: 26 bytes on wire (208 bits), 26 bytes captured (208 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0001 CRC: 0xdba6b7 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 60 84.313 Slave_0xeeafb3c9 LE 1M ATT 24 151 0 1 False 6 Rcvd Read By Group Type Response, Attribute List Length: 3, Generic Access Profile, Battery Service, Immediate Alert Frame 60: 50 bytes on wire (400 bits), 50 bytes captured (400 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x1806 [L2CAP Index: 2] CRC: 0xd06652 Bluetooth L2CAP Protocol Bluetooth Attribute Protocol Opcode: Read By Group Type Response (0x11) Length: 6 Attribute Data, Handle: 0x0001, Group End Handle: 0x0005, UUID: Generic Access Profile Attribute Data, Handle: 0x0006, Group End Handle: 0x0008, UUID: Battery Service Attribute Data, Handle: 0x0009, Group End Handle: 0x000b, UUID: Immediate Alert [UUID: GATT Primary Service Declaration (0x2800)] [Request in Frame: 57] No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 61 84.313 Master_0xeeafb3c9 LE 1M ATT 11 44496 1 1 False 7 Sent Read By Group Type Request, GATT Primary Service Declaration, Handles: 0x000c..0xffff Frame 61: 37 bytes on wire (296 bits), 37 bytes captured (296 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0b0e [L2CAP Index: 3] CRC: 0x78ef61 Bluetooth L2CAP Protocol Bluetooth Attribute Protocol Opcode: Read By Group Type Request (0x10) Starting Handle: 0x000c Ending Handle: 0xffff UUID: GATT Primary Service Declaration (0x2800) [Response in Frame: 64] No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 62 84.313 Slave_0xeeafb3c9 LE 1M LE LL 0 152 1 0 False 7 Empty PDU Frame 62: 26 bytes on wire (208 bits), 26 bytes captured (208 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0009 CRC: 0xbe16b7 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 63 84.419 Master_0xeeafb3c9 LE 1M LE LL 0 44600 0 0 False 8 Empty PDU Frame 63: 26 bytes on wire (208 bits), 26 bytes captured (208 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0001 CRC: 0xdba6b7 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 64 84.420 Slave_0xeeafb3c9 LE 1M ATT 12 151 0 1 False 8 Rcvd Read By Group Type Response, Attribute List Length: 1, Unknown Frame 64: 38 bytes on wire (304 bits), 38 bytes captured (304 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0c06 [L2CAP Index: 4] CRC: 0x8b9f3e Bluetooth L2CAP Protocol Bluetooth Attribute Protocol Opcode: Read By Group Type Response (0x11) Length: 6 Attribute Data, Handle: 0x000c, Group End Handle: 0x000e, UUID: Unknown [UUID: GATT Primary Service Declaration (0x2800)] [Request in Frame: 61] No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 65 84.421 Master_0xeeafb3c9 LE 1M ATT 11 44593 1 1 False 9 Sent Read By Group Type Request, GATT Primary Service Declaration, Handles: 0x000f..0xffff Frame 65: 37 bytes on wire (296 bits), 37 bytes captured (296 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0b0e [L2CAP Index: 5] CRC: 0xc88927 Bluetooth L2CAP Protocol Bluetooth Attribute Protocol Opcode: Read By Group Type Request (0x10) Starting Handle: 0x000f Ending Handle: 0xffff UUID: GATT Primary Service Declaration (0x2800) [Response in Frame: 67] No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 66 84.522 Master_0xeeafb3c9 LE 1M LE LL 0 44832 0 0 False 10 Empty PDU Frame 66: 26 bytes on wire (208 bits), 26 bytes captured (208 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0001 CRC: 0xdba6b7 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 67 84.524 Slave_0xeeafb3c9 LE 1M ATT 9 151 0 1 False 10 Rcvd Error Response - Attribute Not Found, Handle: 0x000f (Unknown: Unknown) Frame 67: 35 bytes on wire (280 bits), 35 bytes captured (280 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0906 [L2CAP Index: 6] CRC: 0x493b65 Bluetooth L2CAP Protocol Bluetooth Attribute Protocol Opcode: Error Response (0x01) Request Opcode in Error: Read By Group Type Request (0x10) Handle in Error: 0x000f (Unknown: Unknown) Error Code: Attribute Not Found (0x0a) [UUID: GATT Primary Service Declaration (0x2800)] [Request in Frame: 65] No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 68 84.525 Master_0xeeafb3c9 LE 1M ATT 11 44616 1 1 False 11 Sent Read By Type Request, GATT Include Declaration, Handles: 0x0001..0x0005 Frame 68: 37 bytes on wire (296 bits), 37 bytes captured (296 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0b0e [L2CAP Index: 7] CRC: 0xdd919b Bluetooth L2CAP Protocol Bluetooth Attribute Protocol Opcode: Read By Type Request (0x08) Starting Handle: 0x0001 Ending Handle: 0x0005 UUID: GATT Include Declaration (0x2802) [Response in Frame: 70] No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 69 84.525 Master_0xeeafb3c9 LE 1M LE LL 0 44832 0 0 False 12 Empty PDU Frame 69: 26 bytes on wire (208 bits), 26 bytes captured (208 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0001 CRC: 0xdba6b7 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 70 84.526 Slave_0xeeafb3c9 LE 1M ATT 9 151 0 1 False 12 Rcvd Error Response - Attribute Not Found, Handle: 0x0001 (Generic Access Profile) Frame 70: 35 bytes on wire (280 bits), 35 bytes captured (280 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0906 [L2CAP Index: 8] CRC: 0xbe644e Bluetooth L2CAP Protocol Bluetooth Attribute Protocol Opcode: Error Response (0x01) Request Opcode in Error: Read By Type Request (0x08) Handle in Error: 0x0001 (Generic Access Profile) Error Code: Attribute Not Found (0x0a) [UUID: GATT Include Declaration (0x2802)] [Request in Frame: 68] No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 71 84.626 Master_0xeeafb3c9 LE 1M ATT 11 44617 1 1 False 13 Sent Read By Type Request, GATT Characteristic Declaration, Handles: 0x0001..0x0005 Frame 71: 37 bytes on wire (296 bits), 37 bytes captured (296 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0b0e [L2CAP Index: 9] CRC: 0xf01b76 Bluetooth L2CAP Protocol Bluetooth Attribute Protocol Opcode: Read By Type Request (0x08) Starting Handle: 0x0001 Ending Handle: 0x0005 UUID: GATT Characteristic Declaration (0x2803) [Response in Frame: 74] No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 72 84.627 Slave_0xeeafb3c9 LE 1M LE LL 0 151 1 0 False 13 Empty PDU Frame 72: 26 bytes on wire (208 bits), 26 bytes captured (208 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0009 CRC: 0xbe16b7 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 73 84.629 Master_0xeeafb3c9 LE 1M LE LL 0 7101 0 0 False 14 Empty PDU Frame 73: 26 bytes on wire (208 bits), 26 bytes captured (208 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0001 CRC: 0xdba6b7 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 74 84.630 Slave_0xeeafb3c9 LE 1M ATT 20 151 0 1 False 14 Rcvd Read By Type Response, Attribute List Length: 2, Device Name, Appearance Frame 74: 46 bytes on wire (368 bits), 46 bytes captured (368 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x1406 [L2CAP Index: 10] CRC: 0x0e1c41 Bluetooth L2CAP Protocol Bluetooth Attribute Protocol Opcode: Read By Type Response (0x09) Length: 7 Attribute Data, Handle: 0x0002, Characteristic Handle: 0x0003, UUID: Device Name Attribute Data, Handle: 0x0004, Characteristic Handle: 0x0005, UUID: Appearance [UUID: GATT Characteristic Declaration (0x2803)] [Request in Frame: 71] No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 75 84.631 Master_0xeeafb3c9 LE 1M ATT 11 7029 1 1 False 15 Sent Read By Type Request, GATT Characteristic Declaration, Handles: 0x0005..0x0005 Frame 75: 37 bytes on wire (296 bits), 37 bytes captured (296 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0b0e [L2CAP Index: 11] CRC: 0xc7f597 Bluetooth L2CAP Protocol Bluetooth Attribute Protocol Opcode: Read By Type Request (0x08) Starting Handle: 0x0005 Ending Handle: 0x0005 UUID: GATT Characteristic Declaration (0x2803) [Response in Frame: 78] No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 76 84.633 Slave_0xeeafb3c9 LE 1M LE LL 0 151 1 0 False 15 Empty PDU Frame 76: 26 bytes on wire (208 bits), 26 bytes captured (208 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0009 CRC: 0xbe16b7 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 77 84.634 Master_0xeeafb3c9 LE 1M LE LL 0 7101 0 0 False 16 Empty PDU Frame 77: 26 bytes on wire (208 bits), 26 bytes captured (208 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0001 CRC: 0xdba6b7 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 78 84.635 Slave_0xeeafb3c9 LE 1M ATT 9 151 0 1 False 16 Rcvd Error Response - Attribute Not Found, Handle: 0x0005 (Generic Access Profile: Appearance) Frame 78: 35 bytes on wire (280 bits), 35 bytes captured (280 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0906 [L2CAP Index: 12] CRC: 0xdce73b Bluetooth L2CAP Protocol Bluetooth Attribute Protocol Opcode: Error Response (0x01) Request Opcode in Error: Read By Type Request (0x08) Handle in Error: 0x0005 (Generic Access Profile: Appearance) Error Code: Attribute Not Found (0x0a) [UUID: GATT Characteristic Declaration (0x2803)] [Request in Frame: 75] No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 79 84.636 Master_0xeeafb3c9 LE 1M ATT 11 7117 1 1 False 17 Sent Read By Type Request, GATT Include Declaration, Handles: 0x0006..0x0008 Frame 79: 37 bytes on wire (296 bits), 37 bytes captured (296 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0b0e [L2CAP Index: 13] CRC: 0x91b3cf Bluetooth L2CAP Protocol Bluetooth Attribute Protocol Opcode: Read By Type Request (0x08) Starting Handle: 0x0006 Ending Handle: 0x0008 UUID: GATT Include Declaration (0x2802) [Response in Frame: 82] No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 80 84.636 Slave_0xeeafb3c9 LE 1M LE LL 0 151 1 0 False 17 Empty PDU Frame 80: 26 bytes on wire (208 bits), 26 bytes captured (208 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0009 CRC: 0xbe16b7 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 81 84.637 Master_0xeeafb3c9 LE 1M LE LL 0 7101 0 0 False 18 Empty PDU Frame 81: 26 bytes on wire (208 bits), 26 bytes captured (208 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0001 CRC: 0xdba6b7 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 82 84.638 Slave_0xeeafb3c9 LE 1M ATT 9 151 0 1 False 18 Rcvd Error Response - Attribute Not Found, Handle: 0x0006 (Battery Service) Frame 82: 35 bytes on wire (280 bits), 35 bytes captured (280 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0906 [L2CAP Index: 14] CRC: 0x93ea5e Bluetooth L2CAP Protocol Bluetooth Attribute Protocol Opcode: Error Response (0x01) Request Opcode in Error: Read By Type Request (0x08) Handle in Error: 0x0006 (Battery Service) Error Code: Attribute Not Found (0x0a) [UUID: GATT Include Declaration (0x2802)] [Request in Frame: 79] No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 83 84.638 Master_0xeeafb3c9 LE 1M ATT 11 7116 1 1 False 19 Sent Read By Type Request, GATT Characteristic Declaration, Handles: 0x0006..0x0008 Frame 83: 37 bytes on wire (296 bits), 37 bytes captured (296 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0b0e [L2CAP Index: 15] CRC: 0xbc3922 Bluetooth L2CAP Protocol Bluetooth Attribute Protocol Opcode: Read By Type Request (0x08) Starting Handle: 0x0006 Ending Handle: 0x0008 UUID: GATT Characteristic Declaration (0x2803) [Response in Frame: 86] No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 84 84.639 Slave_0xeeafb3c9 LE 1M LE LL 0 152 1 0 False 19 Empty PDU Frame 84: 26 bytes on wire (208 bits), 26 bytes captured (208 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0009 CRC: 0xbe16b7 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 85 84.639 Master_0xeeafb3c9 LE 1M LE LL 0 7100 0 0 False 20 Empty PDU Frame 85: 26 bytes on wire (208 bits), 26 bytes captured (208 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0001 CRC: 0xdba6b7 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 86 84.639 Slave_0xeeafb3c9 LE 1M ATT 13 152 0 1 False 20 Rcvd Read By Type Response, Attribute List Length: 1, Battery Level Frame 86: 39 bytes on wire (312 bits), 39 bytes captured (312 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0d06 [L2CAP Index: 16] CRC: 0x3c8474 Bluetooth L2CAP Protocol Bluetooth Attribute Protocol Opcode: Read By Type Response (0x09) Length: 7 Attribute Data, Handle: 0x0007, Characteristic Handle: 0x0008, UUID: Battery Level [UUID: GATT Characteristic Declaration (0x2803)] [Request in Frame: 83] No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 87 84.640 Master_0xeeafb3c9 LE 1M ATT 11 7084 1 1 False 21 Sent Read By Type Request, GATT Characteristic Declaration, Handles: 0x0008..0x0008 Frame 87: 37 bytes on wire (296 bits), 37 bytes captured (296 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0b0e [L2CAP Index: 17] CRC: 0x7ffe5c Bluetooth L2CAP Protocol Bluetooth Attribute Protocol Opcode: Read By Type Request (0x08) Starting Handle: 0x0008 Ending Handle: 0x0008 UUID: GATT Characteristic Declaration (0x2803) [Response in Frame: 90] No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 88 84.640 Slave_0xeeafb3c9 LE 1M LE LL 0 152 1 0 False 21 Empty PDU Frame 88: 26 bytes on wire (208 bits), 26 bytes captured (208 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0009 CRC: 0xbe16b7 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 89 84.641 Master_0xeeafb3c9 LE 1M LE LL 0 7100 0 0 False 22 Empty PDU Frame 89: 26 bytes on wire (208 bits), 26 bytes captured (208 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0001 CRC: 0xdba6b7 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 90 84.641 Slave_0xeeafb3c9 LE 1M ATT 9 152 0 1 False 22 Rcvd Error Response - Attribute Not Found, Handle: 0x0008 (Battery Service: Battery Level) Frame 90: 35 bytes on wire (280 bits), 35 bytes captured (280 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0906 [L2CAP Index: 18] CRC: 0x852d56 Bluetooth L2CAP Protocol Bluetooth Attribute Protocol Opcode: Error Response (0x01) Request Opcode in Error: Read By Type Request (0x08) Handle in Error: 0x0008 (Battery Service: Battery Level) Error Code: Attribute Not Found (0x0a) [UUID: GATT Characteristic Declaration (0x2803)] [Request in Frame: 87] No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 91 84.743 Master_0xeeafb3c9 LE 1M ATT 11 7116 1 1 False 23 Sent Read By Type Request, GATT Include Declaration, Handles: 0x0009..0x000b Frame 91: 37 bytes on wire (296 bits), 37 bytes captured (296 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0b0e [L2CAP Index: 19] CRC: 0x811dac Bluetooth L2CAP Protocol Bluetooth Attribute Protocol Opcode: Read By Type Request (0x08) Starting Handle: 0x0009 Ending Handle: 0x000b UUID: GATT Include Declaration (0x2802) [Response in Frame: 94] No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 92 84.743 Slave_0xeeafb3c9 LE 1M LE LL 0 152 1 0 False 23 Empty PDU Frame 92: 26 bytes on wire (208 bits), 26 bytes captured (208 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0009 CRC: 0xbe16b7 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 93 84.745 Master_0xeeafb3c9 LE 1M LE LL 0 7100 0 0 False 24 Empty PDU Frame 93: 26 bytes on wire (208 bits), 26 bytes captured (208 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0001 CRC: 0xdba6b7 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 94 84.746 Slave_0xeeafb3c9 LE 1M ATT 9 152 0 1 False 24 Rcvd Error Response - Attribute Not Found, Handle: 0x0009 (Immediate Alert) Frame 94: 35 bytes on wire (280 bits), 35 bytes captured (280 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0906 [L2CAP Index: 20] CRC: 0x0f26d9 Bluetooth L2CAP Protocol Bluetooth Attribute Protocol Opcode: Error Response (0x01) Request Opcode in Error: Read By Type Request (0x08) Handle in Error: 0x0009 (Immediate Alert) Error Code: Attribute Not Found (0x0a) [UUID: GATT Include Declaration (0x2802)] [Request in Frame: 91] No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 95 84.746 Master_0xeeafb3c9 LE 1M ATT 11 7116 1 1 False 25 Sent Read By Type Request, GATT Characteristic Declaration, Handles: 0x0009..0x000b Frame 95: 37 bytes on wire (296 bits), 37 bytes captured (296 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0b0e [L2CAP Index: 21] CRC: 0xac9741 Bluetooth L2CAP Protocol Bluetooth Attribute Protocol Opcode: Read By Type Request (0x08) Starting Handle: 0x0009 Ending Handle: 0x000b UUID: GATT Characteristic Declaration (0x2803) [Response in Frame: 98] No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 96 84.747 Slave_0xeeafb3c9 LE 1M LE LL 0 151 1 0 False 25 Empty PDU Frame 96: 26 bytes on wire (208 bits), 26 bytes captured (208 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0009 CRC: 0xbe16b7 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 97 84.747 Master_0xeeafb3c9 LE 1M LE LL 0 7101 0 0 False 26 Empty PDU Frame 97: 26 bytes on wire (208 bits), 26 bytes captured (208 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0001 CRC: 0xdba6b7 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 98 84.748 Slave_0xeeafb3c9 LE 1M ATT 13 151 0 1 False 26 Rcvd Read By Type Response, Attribute List Length: 1, Alert Level Frame 98: 39 bytes on wire (312 bits), 39 bytes captured (312 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0d06 [L2CAP Index: 22] CRC: 0xcdda67 Bluetooth L2CAP Protocol Bluetooth Attribute Protocol Opcode: Read By Type Response (0x09) Length: 7 Attribute Data, Handle: 0x000a, Characteristic Handle: 0x000b, UUID: Alert Level [UUID: GATT Characteristic Declaration (0x2803)] [Request in Frame: 95] No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 99 84.748 Master_0xeeafb3c9 LE 1M ATT 11 7085 1 1 False 27 Sent Read By Type Request, GATT Characteristic Declaration, Handles: 0x000b..0x000b Frame 99: 37 bytes on wire (296 bits), 37 bytes captured (296 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0b0e [L2CAP Index: 23] CRC: 0xc34a83 Bluetooth L2CAP Protocol Bluetooth Attribute Protocol Opcode: Read By Type Request (0x08) Starting Handle: 0x000b Ending Handle: 0x000b UUID: GATT Characteristic Declaration (0x2803) [Response in Frame: 101] No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 100 84.749 Master_0xeeafb3c9 LE 1M LE LL 0 7332 0 0 False 28 Empty PDU Frame 100: 26 bytes on wire (208 bits), 26 bytes captured (208 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0001 CRC: 0xdba6b7 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 101 84.749 Slave_0xeeafb3c9 LE 1M ATT 9 152 0 1 False 28 Rcvd Error Response - Attribute Not Found, Handle: 0x000b (Immediate Alert: Alert Level) Frame 101: 35 bytes on wire (280 bits), 35 bytes captured (280 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0906 [L2CAP Index: 24] CRC: 0xca2033 Bluetooth L2CAP Protocol Bluetooth Attribute Protocol Opcode: Error Response (0x01) Request Opcode in Error: Read By Type Request (0x08) Handle in Error: 0x000b (Immediate Alert: Alert Level) Error Code: Attribute Not Found (0x0a) [UUID: GATT Characteristic Declaration (0x2803)] [Request in Frame: 99] No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 102 84.749 Master_0xeeafb3c9 LE 1M ATT 11 7116 1 1 False 29 Sent Read By Type Request, GATT Include Declaration, Handles: 0x000c..0x000e Frame 102: 37 bytes on wire (296 bits), 37 bytes captured (296 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0b0e [L2CAP Index: 25] CRC: 0xe3f031 Bluetooth L2CAP Protocol Bluetooth Attribute Protocol Opcode: Read By Type Request (0x08) Starting Handle: 0x000c Ending Handle: 0x000e UUID: GATT Include Declaration (0x2802) [Response in Frame: 105] No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 103 84.750 Slave_0xeeafb3c9 LE 1M LE LL 0 151 1 0 False 29 Empty PDU Frame 103: 26 bytes on wire (208 bits), 26 bytes captured (208 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0009 CRC: 0xbe16b7 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 104 84.750 Master_0xeeafb3c9 LE 1M LE LL 0 7101 0 0 False 30 Empty PDU Frame 104: 26 bytes on wire (208 bits), 26 bytes captured (208 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0001 CRC: 0xdba6b7 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 105 84.750 Slave_0xeeafb3c9 LE 1M ATT 9 151 0 1 False 30 Rcvd Error Response - Attribute Not Found, Handle: 0x000c (Unknown) Frame 105: 35 bytes on wire (280 bits), 35 bytes captured (280 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0906 [L2CAP Index: 26] CRC: 0xe7ae23 Bluetooth L2CAP Protocol Bluetooth Attribute Protocol Opcode: Error Response (0x01) Request Opcode in Error: Read By Type Request (0x08) Handle in Error: 0x000c (Unknown) Error Code: Attribute Not Found (0x0a) [UUID: GATT Include Declaration (0x2802)] [Request in Frame: 102] No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 106 84.750 Master_0xeeafb3c9 LE 1M ATT 11 7117 1 1 False 31 Sent Read By Type Request, GATT Characteristic Declaration, Handles: 0x000c..0x000e Frame 106: 37 bytes on wire (296 bits), 37 bytes captured (296 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0b0e [L2CAP Index: 27] CRC: 0xce7adc Bluetooth L2CAP Protocol Bluetooth Attribute Protocol Opcode: Read By Type Request (0x08) Starting Handle: 0x000c Ending Handle: 0x000e UUID: GATT Characteristic Declaration (0x2803) [Response in Frame: 109] No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 107 84.751 Slave_0xeeafb3c9 LE 1M LE LL 0 151 1 0 False 31 Empty PDU Frame 107: 26 bytes on wire (208 bits), 26 bytes captured (208 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0009 CRC: 0xbe16b7 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 108 84.751 Master_0xeeafb3c9 LE 1M LE LL 0 7101 0 0 False 32 Empty PDU Frame 108: 26 bytes on wire (208 bits), 26 bytes captured (208 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0001 CRC: 0xdba6b7 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 109 84.751 Slave_0xeeafb3c9 LE 1M ATT 13 151 0 1 False 32 Rcvd Read By Type Response, Attribute List Length: 1, Unknown Frame 109: 39 bytes on wire (312 bits), 39 bytes captured (312 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0d06 [L2CAP Index: 28] CRC: 0xd64a3c Bluetooth L2CAP Protocol Bluetooth Attribute Protocol Opcode: Read By Type Response (0x09) Length: 7 Attribute Data, Handle: 0x000d, Characteristic Handle: 0x000e, UUID: Unknown [UUID: GATT Characteristic Declaration (0x2803)] [Request in Frame: 106] No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 110 84.752 Master_0xeeafb3c9 LE 1M ATT 11 7085 1 1 False 33 Sent Read By Type Request, GATT Characteristic Declaration, Handles: 0x000e..0x000e Frame 110: 37 bytes on wire (296 bits), 37 bytes captured (296 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0b0e [L2CAP Index: 29] CRC: 0xa1a71e Bluetooth L2CAP Protocol Bluetooth Attribute Protocol Opcode: Read By Type Request (0x08) Starting Handle: 0x000e Ending Handle: 0x000e UUID: GATT Characteristic Declaration (0x2803) [Response in Frame: 113] No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 111 84.753 Slave_0xeeafb3c9 LE 1M LE LL 0 151 1 0 False 33 Empty PDU Frame 111: 26 bytes on wire (208 bits), 26 bytes captured (208 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0009 CRC: 0xbe16b7 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 112 84.754 Master_0xeeafb3c9 LE 1M LE LL 0 7101 0 0 False 34 Empty PDU Frame 112: 26 bytes on wire (208 bits), 26 bytes captured (208 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0001 CRC: 0xdba6b7 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 113 84.755 Slave_0xeeafb3c9 LE 1M ATT 9 151 0 1 False 34 Rcvd Error Response - Attribute Not Found, Handle: 0x000e (Unknown: Unknown) Frame 113: 35 bytes on wire (280 bits), 35 bytes captured (280 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0906 [L2CAP Index: 30] CRC: 0x22a8c9 Bluetooth L2CAP Protocol Bluetooth Attribute Protocol Opcode: Error Response (0x01) Request Opcode in Error: Read By Type Request (0x08) Handle in Error: 0x000e (Unknown: Unknown) Error Code: Attribute Not Found (0x0a) [UUID: GATT Characteristic Declaration (0x2803)] [Request in Frame: 110] No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 114 84.755 Master_0xeeafb3c9 LE 1M LE LL 12 7117 1 1 False 35 Control Opcode: LL_CONNECTION_UPDATE_REQ Frame 114: 38 bytes on wire (304 bits), 38 bytes captured (304 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0c0f Control Opcode: LL_CONNECTION_UPDATE_REQ (0x00) Window Size: 1 Window Offset: 30 Interval: 36 Latency: 0 Timeout: 500 Instant: 44 CRC: 0xdd9295 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 115 84.756 Slave_0xeeafb3c9 LE 1M LE LL 0 151 1 0 False 35 Empty PDU Frame 115: 26 bytes on wire (208 bits), 26 bytes captured (208 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0009 CRC: 0xbe16b7 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 116 84.756 Master_0xeeafb3c9 LE 1M LE LL 0 7093 0 0 False 36 Empty PDU Frame 116: 26 bytes on wire (208 bits), 26 bytes captured (208 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0001 CRC: 0xdba6b7 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 117 84.756 Slave_0xeeafb3c9 LE 1M LE LL 0 151 0 1 False 36 Empty PDU Frame 117: 26 bytes on wire (208 bits), 26 bytes captured (208 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0005 CRC: 0x10c6b7 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 118 84.757 Master_0xeeafb3c9 LE 1M LE LL 0 7189 1 1 False 37 Empty PDU Frame 118: 26 bytes on wire (208 bits), 26 bytes captured (208 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x000d CRC: 0x7576b7 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 119 84.757 Slave_0xeeafb3c9 LE 1M LE LL 0 151 1 0 False 37 Empty PDU Frame 119: 26 bytes on wire (208 bits), 26 bytes captured (208 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0009 CRC: 0xbe16b7 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 120 84.757 Master_0xeeafb3c9 LE 1M LE LL 0 7189 0 0 False 38 Empty PDU Frame 120: 26 bytes on wire (208 bits), 26 bytes captured (208 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0001 CRC: 0xdba6b7 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 121 84.757 Slave_0xeeafb3c9 LE 1M LE LL 0 151 0 1 False 38 Empty PDU Frame 121: 26 bytes on wire (208 bits), 26 bytes captured (208 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0005 CRC: 0x10c6b7 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 122 84.862 Master_0xeeafb3c9 LE 1M LE LL 0 7189 1 1 False 39 Empty PDU Frame 122: 26 bytes on wire (208 bits), 26 bytes captured (208 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x000d CRC: 0x7576b7 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 123 84.862 Slave_0xeeafb3c9 LE 1M LE LL 0 151 1 0 False 39 Empty PDU Frame 123: 26 bytes on wire (208 bits), 26 bytes captured (208 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0009 CRC: 0xbe16b7 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 124 84.863 Master_0xeeafb3c9 LE 1M LE LL 0 7189 0 0 False 40 Empty PDU Frame 124: 26 bytes on wire (208 bits), 26 bytes captured (208 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0001 CRC: 0xdba6b7 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 125 84.863 Slave_0xeeafb3c9 LE 1M LE LL 0 151 0 1 False 40 Empty PDU Frame 125: 26 bytes on wire (208 bits), 26 bytes captured (208 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0005 CRC: 0x10c6b7 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 126 84.864 Master_0xeeafb3c9 LE 1M LE LL 0 7189 1 1 False 41 Empty PDU Frame 126: 26 bytes on wire (208 bits), 26 bytes captured (208 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x000d CRC: 0x7576b7 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 127 84.864 Slave_0xeeafb3c9 LE 1M LE LL 0 151 1 0 False 41 Empty PDU Frame 127: 26 bytes on wire (208 bits), 26 bytes captured (208 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0009 CRC: 0xbe16b7 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 128 84.865 Master_0xeeafb3c9 LE 1M LE LL 0 7189 0 0 False 42 Empty PDU Frame 128: 26 bytes on wire (208 bits), 26 bytes captured (208 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0001 CRC: 0xdba6b7 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 129 84.865 Slave_0xeeafb3c9 LE 1M LE LL 0 151 0 1 False 42 Empty PDU Frame 129: 26 bytes on wire (208 bits), 26 bytes captured (208 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0005 CRC: 0x10c6b7 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 130 84.866 Master_0xeeafb3c9 LE 1M LE LL 0 7189 1 1 False 43 Empty PDU Frame 130: 26 bytes on wire (208 bits), 26 bytes captured (208 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x000d CRC: 0x7576b7 No. Time Source PHY Protocol Length Delta time (µs end to start) SN NESN More Data Event counter Info 131 84.866 Slave_0xeeafb3c9 LE 1M LE LL 0 151 1 0 False 43 Empty PDU Frame 131: 26 bytes on wire (208 bits), 26 bytes captured (208 bits) on interface 0 Nordic BLE Sniffer Bluetooth Low Energy Link Layer Access Address: 0xeeafb3c9 [Master Address: 75:f9:6a:24:6f:be (75:f9:6a:24:6f:be)] [Slave Address: ff:ff:c0:18:01:83 (ff:ff:c0:18:01:83)] Data Header: 0x0009 CRC: 0xbe16b7