SEGGER J-Link GDB Server V6.40 Command Line Version JLinkARM.dll V6.40 (DLL compiled Oct 26 2018 15:06:02) Command line: -if swd -device nRF52840_xxAA -endian little -speed 1000 -port 2331 -swoport 2332 -telnetport 2333 -vd -ir -localhostonly 1 -singlerun -strict -timeout 0 -nogui -----GDB Server start settings----- GDBInit file: none GDB Server Listening port: 2331 SWO raw output listening port: 2332 Terminal I/O port: 2333 Accept remote connection: localhost only Generate logfile: off Verify download: on Init regs on start: on Silent mode: off Single run mode: on Target connection timeout: 0 ms ------J-Link related settings------ J-Link Host interface: USB J-Link script: none J-Link settings file: none ------Target related settings------ Target device: nRF52840_xxAA Target interface: SWD Target interface speed: 1000kHz Target endian: little Connecting to J-Link... J-Link is connected. Firmware: J-Link OB-SAM3U128-V2-NordicSemi compiled Jul 12 2018 11:44:41 Hardware: V1.00 S/N: 683146273 Checking target voltage... Target voltage: 3.30 V Listening on TCP/IP port 2331 Connecting to target...Connected to target Waiting for GDB connection...Connected to 127.0.0.1 Reading all registers Read 4 bytes @ address 0x00000000 (Data = 0x20000400) Read 2 bytes @ address 0x00000000 (Data = 0x0400) Received monitor command: speed 1000 Target interface speed set to 1000 kHz Received monitor command: clrbp Received monitor command: reset Resetting target Received monitor command: halt Halting target CPU... ...Target halted (PC = 0x00000998) Received monitor command: regs R0 = 00000000, R1 = 00000000, R2 = 00000000, R3 = 00000000 R4 = 00000000, R5 = 00000000, R6 = 00000000, R7 = 00000000 R8 = 00000000, R9 = 00000000, R10= 00000000, R11= 00000000 R12= 00000000, R13= 20000400, MSP= 20000400, PSP= 00000000 R14(LR) = FFFFFFFF, R15(PC) = 00000998 XPSR 01000000, APSR 00000000, EPSR 01000000, IPSR 00000000 CFBP 00000000, CONTROL 00, FAULTMASK 00, BASEPRI 00, PRIMASK 00 Reading all registers Read 4 bytes @ address 0x00000998 (Data = 0x47184B06) Read 2 bytes @ address 0x00000998 (Data = 0x4B06) Received monitor command: speed auto Select auto target interface speed (1000 kHz) Received monitor command: flash breakpoints 1 Flash breakpoints enabled Received monitor command: semihosting enable Semi-hosting enabled (Handle on BKPT) Received monitor command: semihosting IOClient 1 Semihosting I/O set to TELNET Client Received monitor command: SWO DisableTarget 0xFFFFFFFF SWO disabled successfully. Received monitor command: SWO EnableTarget 0 0 0x1 0 SWO enabled successfully. Read 4 bytes @ address 0x00000998 (Data = 0x47184B06) Read 2 bytes @ address 0x00000998 (Data = 0x4B06) Downloading 1748 bytes @ address 0x00001000 - Verified OK Downloading 8 bytes @ address 0x000016D4 - Verified OK Downloading 112 bytes @ address 0x000016DC - Verified OK Comparing flash [....................] Done. Verifying flash [....................] Done. Writing register (PC = 0x 12e0) Read 4 bytes @ address 0x000012E0 (Data = 0x4A074906) Read 2 bytes @ address 0x000012E0 (Data = 0x4906) Received monitor command: clrbp Received monitor command: reset Resetting target Received monitor command: halt Halting target CPU... ...Target halted (PC = 0x00000998) Received monitor command: regs R0 = 00000000, R1 = 00000000, R2 = 00000000, R3 = 00000000 R4 = 00000000, R5 = 00000000, R6 = 00000000, R7 = 00000000 R8 = 00000000, R9 = 00000000, R10= 00000000, R11= 00000000 R12= 00000000, R13= 20000400, MSP= 20000400, PSP= 00000000 R14(LR) = FFFFFFFF, R15(PC) = 00000998 XPSR 01000000, APSR 00000000, EPSR 01000000, IPSR 00000000 CFBP 00000000, CONTROL 00, FAULTMASK 00, BASEPRI 00, PRIMASK 00 Reading all registers Read 4 bytes @ address 0x00000998 (Data = 0x47184B06) Read 2 bytes @ address 0x00000998 (Data = 0x4B06) Starting target CPU...