2020-05-12T06:14:06.562Z DEBUG modem >> AT\x0D\x0A 2020-05-12T06:14:06.584Z DEBUG modem << OK\x0D\x0A\x00 2020-05-12T06:14:15.597Z DEBUG modem >> AT\x0D\x0A 2020-05-12T06:14:15.624Z DEBUG modem << OK\x0D\x0A\x00 2020-05-12T06:15:04.011Z DEBUG modem >> AT+CFUN?\x0D\x0A 2020-05-12T06:15:04.034Z DEBUG modem << +CFUN: 0\x0D 2020-05-12T06:15:04.064Z DEBUG modem << OK\x0D\x0A\x00 2020-05-12T06:15:15.596Z DEBUG modem >> AT+CFUN=1\x0D\x0A 2020-05-12T06:15:15.637Z DEBUG modem << OK\x0D\x0A\x00 2020-05-12T06:15:18.133Z DEBUG modem >> AT+CFUN=1\x0D\x0A 2020-05-12T06:15:18.138Z DEBUG modem << OK\x0D\x0A\x00 2020-05-12T06:15:21.143Z DEBUG modem >> AT+CFUN?\x0D\x0A 2020-05-12T06:15:21.169Z DEBUG modem << +CFUN: 1\x0D 2020-05-12T06:15:21.198Z DEBUG modem << OK\x0D\x0A\x00 2020-05-12T06:15:21.201Z DEBUG modem >> AT+CGSN=1\x0D\x0A 2020-05-12T06:15:21.208Z DEBUG modem << +CGSN: "352656100378499"\x0D 2020-05-12T06:15:21.243Z DEBUG modem << \x0A 2020-05-12T06:15:21.244Z DEBUG modem << OK\x0D\x0A\x00 2020-05-12T06:15:21.247Z DEBUG modem >> AT+CGMI\x0D\x0A 2020-05-12T06:15:21.253Z DEBUG modem << Nordic Semiconductor ASA\x0D 2020-05-12T06:15:21.282Z DEBUG modem << \x0A 2020-05-12T06:15:21.283Z DEBUG modem << OK\x0D\x0A\x00 2020-05-12T06:15:21.287Z DEBUG modem >> AT+CGMM\x0D\x0A 2020-05-12T06:15:21.292Z DEBUG modem << nRF9160-SICA\x0D 2020-05-12T06:15:21.294Z DEBUG modem << \x0A 2020-05-12T06:15:21.295Z DEBUG modem << OK\x0D\x0A\x00 2020-05-12T06:15:21.316Z DEBUG modem >> AT+CGMR\x0D\x0A 2020-05-12T06:15:21.341Z DEBUG modem << mfw_nrf9160_1.1.1\x0D\x0A 2020-05-12T06:15:21.342Z DEBUG modem << OK\x0D\x0A\x00 2020-05-12T06:15:21.343Z INFO Nordic Semiconductor ASA nRF9160-SICA [mfw_nrf9160_1.1.1] SerNr: 352656100378499 2020-05-12T06:15:21.344Z DEBUG modem >> AT+CEMODE?\x0D\x0A 2020-05-12T06:15:21.372Z DEBUG modem << +CEMODE: 2\x0D\x0A 2020-05-12T06:15:21.374Z DEBUG modem << OK\x0D\x0A\x00 2020-05-12T06:15:21.400Z DEBUG modem >> AT%XCBAND=?\x0D\x0A 2020-05-12T06:15:21.425Z DEBUG modem << %XCBAND: (1,2,3,4,5,8,12,13,14,17,18,19,20,25,26,28,66)\x0D\x0A 2020-05-12T06:15:21.428Z DEBUG modem << OK\x0D\x0A\x00 2020-05-12T06:15:21.467Z DEBUG modem >> AT+CMEE?\x0D\x0A 2020-05-12T06:15:21.504Z DEBUG modem << +CMEE: 0\x0D\x0A 2020-05-12T06:15:21.505Z DEBUG modem << OK\x0D\x0A\x00 2020-05-12T06:15:21.507Z DEBUG modem >> AT+CMEE=1\x0D\x0A 2020-05-12T06:15:21.511Z DEBUG modem << OK\x0D\x0A\x00 2020-05-12T06:15:21.557Z DEBUG modem >> AT+CNEC?\x0D\x0A 2020-05-12T06:15:21.601Z DEBUG modem << +CNEC: 0\x0D\x0A 2020-05-12T06:15:21.603Z DEBUG modem << OK\x0D\x0A\x00 2020-05-12T06:15:21.606Z DEBUG modem >> AT+CNEC=24\x0D\x0A 2020-05-12T06:15:21.651Z DEBUG modem << OK\x0D\x0A\x00 2020-05-12T06:15:21.675Z DEBUG modem >> AT+CGEREP?\x0D\x0A 2020-05-12T06:15:21.698Z DEBUG modem << +CGEREP: 0,0\x0D\x0A 2020-05-12T06:15:21.700Z DEBUG modem << OK\x0D\x0A\x00 2020-05-12T06:15:21.702Z DEBUG modem >> AT+CGDCONT?\x0D\x0A 2020-05-12T06:15:21.751Z DEBUG modem << +CGDCONT: 0,"IPV4V6","cmw500.rohde-schwarz.com","192.168.1.30 FC01:ABAB:CDCD:EFE0:0000:0000:0000:0001",0,0\x0D\x0A 2020-05-12T06:15:21.753Z DEBUG modem << OK\x0D\x0A\x00 2020-05-12T06:15:21.758Z DEBUG modem >> AT+CGACT?\x0D\x0A 2020-05-12T06:15:21.803Z DEBUG modem << +CGACT: 0,1\x0D\x0A 2020-05-12T06:15:21.804Z DEBUG modem << OK\x0D\x0A\x00 2020-05-12T06:15:21.843Z DEBUG modem >> AT+CGEREP=1\x0D\x0A 2020-05-12T06:15:21.874Z DEBUG modem << OK\x0D\x0A\x00 2020-05-12T06:15:21.900Z DEBUG modem >> AT+CIND=1,1,1\x0D\x0A 2020-05-12T06:15:21.943Z DEBUG modem << OK\x0D 2020-05-12T06:15:21.984Z DEBUG modem >> AT+CEREG=2\x0D\x0A 2020-05-12T06:15:22.029Z DEBUG modem << OK\x0D\x0A\x00 2020-05-12T06:15:22.032Z DEBUG modem >> AT+CEREG?\x0D\x0A 2020-05-12T06:15:22.078Z DEBUG modem << +CEREG: 2,1,"0001","00000100",7\x0D\x0A 2020-05-12T06:15:22.079Z DEBUG modem << OK\x0D\x0A\x00 2020-05-12T06:15:22.106Z DEBUG modem >> AT+COPS=3,2\x0D\x0A 2020-05-12T06:15:22.128Z DEBUG modem << OK\x0D\x0A\x00 2020-05-12T06:15:22.150Z DEBUG modem >> AT+COPS?\x0D\x0A 2020-05-12T06:15:22.191Z DEBUG modem << +COPS: 0,2,"00101",7\x0D\x0A 2020-05-12T06:15:22.193Z DEBUG modem << OK\x0D\x0A\x00 2020-05-12T06:15:22.228Z DEBUG modem >> AT%XCBAND\x0D\x0A 2020-05-12T06:15:22.254Z DEBUG modem << %XCBAND: 13\x0D\x0A 2020-05-12T06:15:22.256Z DEBUG modem << OK\x0D\x0A\x00 2020-05-12T06:15:22.283Z DEBUG modem >> AT+CGDCONT?\x0D\x0A 2020-05-12T06:15:22.308Z DEBUG modem << +CGDCONT: 0,"IPV4V6","cmw500.rohde-schwarz.com","192.168.1.30 FC01:ABAB:CDCD:EFE0:0000:0000:0000:0001",0,0\x0D\x0A 2020-05-12T06:15:22.311Z DEBUG modem << OK\x0D\x0A\x00 2020-05-12T06:15:22.360Z DEBUG modem >> AT+CGACT?\x0D\x0A 2020-05-12T06:15:22.403Z DEBUG modem << +CGACT: 0,1\x0D\x0A 2020-05-12T06:15:22.425Z DEBUG modem << OK\x0D\x0A\x00 2020-05-12T06:15:22.455Z DEBUG modem >> AT%CESQ=1\x0D\x0A 2020-05-12T06:15:22.499Z DEBUG modem << OK\x0D\x0A\x00 2020-05-12T06:15:22.502Z DEBUG modem >> AT+CESQ\x0D\x0A 2020-05-12T06:15:22.508Z DEBUG modem << +CESQ: 99,99,255,255,28,77\x0D\x0A 2020-05-12T06:15:22.509Z DEBUG modem << OK\x0D\x0A\x00 2020-05-12T06:15:22.513Z DEBUG modem >> AT%XSIM=1\x0D\x0A 2020-05-12T06:15:22.538Z DEBUG modem << OK\x0D 2020-05-12T06:15:22.570Z DEBUG modem >> AT%XSIM?\x0D\x0A 2020-05-12T06:15:22.620Z DEBUG modem << %XSIM: 1\x0D\x0A 2020-05-12T06:15:22.622Z DEBUG modem << OK\x0D\x0A\x00 2020-05-12T06:15:22.674Z DEBUG modem >> AT+CPIN?\x0D\x0A 2020-05-12T06:15:22.719Z DEBUG modem << +CPIN: READY\x0D\x0A 2020-05-12T06:15:22.720Z DEBUG modem << OK\x0D\x0A\x00 2020-05-12T06:15:22.758Z DEBUG modem >> AT+CPINR="SIM PIN"\x0D\x0A 2020-05-12T06:15:22.797Z DEBUG modem << +CPINR: "SIM PIN",3\x0D\x0A 2020-05-12T06:15:22.799Z DEBUG modem << OK\x0D\x0A\x00 2020-05-12T06:15:22.827Z DEBUG modem >> AT+CIMI\x0D\x0A 2020-05-12T06:15:22.851Z DEBUG modem << 001010123456063\x0D\x0A 2020-05-12T06:15:22.853Z DEBUG modem << OK\x0D\x0A\x00 2020-05-12T06:15:22.855Z INFO IMSIdentity: 001010123456063 2020-05-12T06:15:59.130Z DEBUG modem >> AT+CGATT=0\x0D\x0A 2020-05-12T06:16:00.130Z ERROR Error: 'AT+CGATT=0 ' timed out 2020-05-12T06:16:03.661Z DEBUG modem >> AT\x0D\x0A 2020-05-12T06:16:04.661Z ERROR Error: 'AT ' timed out 2020-05-12T06:16:04.662Z DEBUG modem >> AT\x0D\x0A 2020-05-12T06:16:05.663Z ERROR Error: 'AT ' timed out 2020-05-12T06:16:08.315Z DEBUG modem >> AT+CFUN?\x0D\x0A 2020-05-12T06:16:09.316Z ERROR Error: 'AT+CFUN? ' timed out