<?xml-stylesheet type="text/xsl" href="https://devzone.nordicsemi.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:slash="http://purl.org/rss/1.0/modules/slash/" xmlns:wfw="http://wellformedweb.org/CommentAPI/"><channel><title>nRF52840-DK Range Testing With BLE, ZigBee and Thread Protocols at 0, 4 and 8dBm Transmit Power Settings</title><link>/nordic/nordic-blog/b/blog/posts/nrf52840-dk-range-testing-with-ble-zigbee-and-thread-protocols-at-0-4-and-8dbm-transmit-power-settings</link><description>Range testing of any RF scheme is inherently limited by the RF environment, antenna design, tuning and many other factors. The usefulness of range testing is to provide a basis for comparison while keeping as many variables as possible constant. When</description><dc:language>en-US</dc:language><generator>Telligent Community 13</generator><item><title>RE: nRF52840-DK Range Testing With BLE, ZigBee and Thread Protocols at 0, 4 and 8dBm Transmit Power Settings</title><link>https://devzone.nordicsemi.com/nordic/nordic-blog/b/blog/posts/nrf52840-dk-range-testing-with-ble-zigbee-and-thread-protocols-at-0-4-and-8dbm-transmit-power-settings</link><pubDate>Wed, 15 Jul 2020 18:28:31 GMT</pubDate><guid isPermaLink="false">137ad170-7792-4731-bb38-c0d22fbe4515:c81944c0-bfb5-4f99-b43b-987fb22f028f</guid><dc:creator>henbagan</dc:creator><slash:comments>1</slash:comments><description>&lt;p&gt;Hi [mention:df3b84d6091a4b7dba37a7242b473efa:e9ed411860ed4f2ba0265705b8793d05] do you have any test data for how long connections persisted at each distance, phy, and tx power?&amp;nbsp;&lt;/p&gt;&lt;img src="https://devzone.nordicsemi.com/aggbug?PostID=1230&amp;AppID=4&amp;AppType=Weblog&amp;ContentType=0" width="1" height="1"&gt;</description></item><item><title>RE: nRF52840-DK Range Testing With BLE, ZigBee and Thread Protocols at 0, 4 and 8dBm Transmit Power Settings</title><link>https://devzone.nordicsemi.com/nordic/nordic-blog/b/blog/posts/nrf52840-dk-range-testing-with-ble-zigbee-and-thread-protocols-at-0-4-and-8dbm-transmit-power-settings</link><pubDate>Wed, 12 Feb 2020 12:10:24 GMT</pubDate><guid isPermaLink="false">137ad170-7792-4731-bb38-c0d22fbe4515:c81944c0-bfb5-4f99-b43b-987fb22f028f</guid><dc:creator>ran</dc:creator><slash:comments>1</slash:comments><description>&lt;p&gt;Hi&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Why wasn&amp;#39;t the Long-Range was tested @0dBm and 4dBm ?&amp;nbsp;&lt;/p&gt;&lt;img src="https://devzone.nordicsemi.com/aggbug?PostID=1230&amp;AppID=4&amp;AppType=Weblog&amp;ContentType=0" width="1" height="1"&gt;</description></item><item><title>RE: nRF52840-DK Range Testing With BLE, ZigBee and Thread Protocols at 0, 4 and 8dBm Transmit Power Settings</title><link>https://devzone.nordicsemi.com/nordic/nordic-blog/b/blog/posts/nrf52840-dk-range-testing-with-ble-zigbee-and-thread-protocols-at-0-4-and-8dbm-transmit-power-settings</link><pubDate>Thu, 10 Jan 2019 09:38:04 GMT</pubDate><guid isPermaLink="false">137ad170-7792-4731-bb38-c0d22fbe4515:c81944c0-bfb5-4f99-b43b-987fb22f028f</guid><dc:creator>manumonti</dc:creator><slash:comments>0</slash:comments><description>&lt;p&gt;Great work, thank you&lt;/p&gt;&lt;img src="https://devzone.nordicsemi.com/aggbug?PostID=1230&amp;AppID=4&amp;AppType=Weblog&amp;ContentType=0" width="1" height="1"&gt;</description></item><item><title>RE: nRF52840-DK Range Testing With BLE, ZigBee and Thread Protocols at 0, 4 and 8dBm Transmit Power Settings</title><link>https://devzone.nordicsemi.com/nordic/nordic-blog/b/blog/posts/nrf52840-dk-range-testing-with-ble-zigbee-and-thread-protocols-at-0-4-and-8dbm-transmit-power-settings</link><pubDate>Thu, 10 Jan 2019 02:38:38 GMT</pubDate><guid isPermaLink="false">137ad170-7792-4731-bb38-c0d22fbe4515:c81944c0-bfb5-4f99-b43b-987fb22f028f</guid><dc:creator>kren</dc:creator><slash:comments>0</slash:comments><description>&lt;p&gt;A great work you made!&lt;/p&gt;&lt;img src="https://devzone.nordicsemi.com/aggbug?PostID=1230&amp;AppID=4&amp;AppType=Weblog&amp;ContentType=0" width="1" height="1"&gt;</description></item><item><title>RE: nRF52840-DK Range Testing With BLE, ZigBee and Thread Protocols at 0, 4 and 8dBm Transmit Power Settings</title><link>https://devzone.nordicsemi.com/nordic/nordic-blog/b/blog/posts/nrf52840-dk-range-testing-with-ble-zigbee-and-thread-protocols-at-0-4-and-8dbm-transmit-power-settings</link><pubDate>Wed, 09 Jan 2019 18:48:43 GMT</pubDate><guid isPermaLink="false">137ad170-7792-4731-bb38-c0d22fbe4515:c81944c0-bfb5-4f99-b43b-987fb22f028f</guid><dc:creator>WestCoastDaz</dc:creator><slash:comments>3</slash:comments><description>&lt;p&gt;Great summary and timely too, as I am starting to look into this myself.&amp;nbsp; I&amp;#39;m curious about a couple of things:&lt;/p&gt;
&lt;ol&gt;
&lt;li&gt;Your results differ substantially from this post &lt;a href="/b/blog/posts/testing-long-range-coded-phy-with-nordic-solution-it-simply-works-922075585"&gt;https://devzone.nordicsemi.com/b/blog/posts/testing-long-range-coded-phy-with-nordic-solution-it-simply-works-922075585&lt;/a&gt;&amp;nbsp; Did you consider using the hex files from that post in your testing?&amp;nbsp;&lt;/li&gt;
&lt;li&gt;The results for BLE @ 2Mbps see to good when compared to the 1Mbps mode.&amp;nbsp; Shoudn&amp;#39;t they be around half the distance?&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;Thanks!&lt;/p&gt;&lt;img src="https://devzone.nordicsemi.com/aggbug?PostID=1230&amp;AppID=4&amp;AppType=Weblog&amp;ContentType=0" width="1" height="1"&gt;</description></item><item><title>RE: nRF52840-DK Range Testing With BLE, ZigBee and Thread Protocols at 0, 4 and 8dBm Transmit Power Settings</title><link>https://devzone.nordicsemi.com/nordic/nordic-blog/b/blog/posts/nrf52840-dk-range-testing-with-ble-zigbee-and-thread-protocols-at-0-4-and-8dbm-transmit-power-settings</link><pubDate>Tue, 08 Jan 2019 22:25:50 GMT</pubDate><guid isPermaLink="false">137ad170-7792-4731-bb38-c0d22fbe4515:c81944c0-bfb5-4f99-b43b-987fb22f028f</guid><dc:creator>Olaf</dc:creator><slash:comments>0</slash:comments><description>&lt;p&gt;Very interesting, Thanks!&lt;/p&gt;&lt;img src="https://devzone.nordicsemi.com/aggbug?PostID=1230&amp;AppID=4&amp;AppType=Weblog&amp;ContentType=0" width="1" height="1"&gt;</description></item><item><title>RE: nRF52840-DK Range Testing With BLE, ZigBee and Thread Protocols at 0, 4 and 8dBm Transmit Power Settings</title><link>https://devzone.nordicsemi.com/nordic/nordic-blog/b/blog/posts/nrf52840-dk-range-testing-with-ble-zigbee-and-thread-protocols-at-0-4-and-8dbm-transmit-power-settings</link><pubDate>Mon, 07 Jan 2019 17:35:20 GMT</pubDate><guid isPermaLink="false">137ad170-7792-4731-bb38-c0d22fbe4515:c81944c0-bfb5-4f99-b43b-987fb22f028f</guid><dc:creator>Mohammad Afaneh</dc:creator><slash:comments>1</slash:comments><description>&lt;p&gt;Very useful tests and information. Thanks!&lt;/p&gt;
&lt;p&gt;I&amp;rsquo;m curious, how do you expect the nRF52840 USB dongle to perform, especially in the case of BLE 125 kbps (long-range)? Any better or worse?&lt;/p&gt;&lt;img src="https://devzone.nordicsemi.com/aggbug?PostID=1230&amp;AppID=4&amp;AppType=Weblog&amp;ContentType=0" width="1" height="1"&gt;</description></item><item><title>RE: nRF52840-DK Range Testing With BLE, ZigBee and Thread Protocols at 0, 4 and 8dBm Transmit Power Settings</title><link>https://devzone.nordicsemi.com/nordic/nordic-blog/b/blog/posts/nrf52840-dk-range-testing-with-ble-zigbee-and-thread-protocols-at-0-4-and-8dbm-transmit-power-settings</link><pubDate>Mon, 07 Jan 2019 10:27:22 GMT</pubDate><guid isPermaLink="false">137ad170-7792-4731-bb38-c0d22fbe4515:c81944c0-bfb5-4f99-b43b-987fb22f028f</guid><dc:creator>Martin Muhady</dc:creator><slash:comments>1</slash:comments><description>&lt;p&gt;Excelent test. It would be nice compare also power consumption for each test.&amp;nbsp; Can you share main.c source files? Thank you.&lt;/p&gt;&lt;img src="https://devzone.nordicsemi.com/aggbug?PostID=1230&amp;AppID=4&amp;AppType=Weblog&amp;ContentType=0" width="1" height="1"&gt;</description></item><item><title>RE: nRF52840-DK Range Testing With BLE, ZigBee and Thread Protocols at 0, 4 and 8dBm Transmit Power Settings</title><link>https://devzone.nordicsemi.com/nordic/nordic-blog/b/blog/posts/nrf52840-dk-range-testing-with-ble-zigbee-and-thread-protocols-at-0-4-and-8dbm-transmit-power-settings</link><pubDate>Mon, 31 Dec 2018 18:29:24 GMT</pubDate><guid isPermaLink="false">137ad170-7792-4731-bb38-c0d22fbe4515:c81944c0-bfb5-4f99-b43b-987fb22f028f</guid><dc:creator>Jon Helge</dc:creator><slash:comments>1</slash:comments><description>&lt;p&gt;Nice work! Are there any obvious reasons for the difference between Thread and Zigbee?&lt;/p&gt;&lt;img src="https://devzone.nordicsemi.com/aggbug?PostID=1230&amp;AppID=4&amp;AppType=Weblog&amp;ContentType=0" width="1" height="1"&gt;</description></item></channel></rss>