09:45:26.998	Using nrf-device-lib-js version: 0.4.13
09:45:26.998	Using nrf-device-lib version: 0.12.8
09:45:26.998	Using nrfjprog DLL version: 10.16.0
09:45:26.998	Using JLink version: JLink_V7.80c
09:45:27.028	[nrfdl][warning](09:45:27.027) [JlinkARM] JlinkARM version non expected one found: JLink_V7.80c, expected: JLink_V7.66a
09:45:27.028	Installed JLink version does not match the provided version (V7.66a)
09:45:27.166	[nrfdl][error](09:45:27.157) [jlink] [NRFJPROG][DebugProbe][] Failed reading device info.
09:45:27.166	[nrfdl][warning](09:45:27.157) [jlink] [NRFJPROG][DebugProbe][] Warning: Could not read device info because the device is locked.
09:45:27.167	[nrfdl][warning](09:45:27.157) [jlink] [NRFJPROG][DebugProbe][] Warning: No actions other than recover will be available.
09:45:27.167	[nrfdl][warning](09:45:27.157) [jlink] [NRFJPROG][DebugProbe][] Warning: Try recovering the device if you want to unlock it.
09:45:27.167	[nrfdl][warning](09:45:27.157) [jlink] [NRFJPROG][DebugProbe][] Device info is blank. Attempting to reread.
09:45:27.170	[nrfdl][error](09:45:27.163) [jlink] [NRFJPROG][nRF52][] Access protection is enabled, can't read device version.
09:45:27.175	[nrfdl][error](09:45:27.166) [jlink] [NRFJPROG][DebugProbe][] Failed reading device info.
09:45:27.175	[nrfdl][warning](09:45:27.166) [jlink] [NRFJPROG][DebugProbe][] Warning: Could not read device info because the device is locked.
09:45:27.177	[nrfdl][warning](09:45:27.166) [jlink] [NRFJPROG][DebugProbe][] Warning: No actions other than recover will be available.
09:45:27.177	[nrfdl][warning](09:45:27.166) [jlink] [NRFJPROG][DebugProbe][] Warning: Try recovering the device if you want to unlock it.
09:45:27.177	[nrfdl][error](09:45:27.166) [jlink] [NRFJPROG][HighLevel][] Failed to read device info from the device.
09:45:27.182	[nrfdl][error](09:45:27.177) [jlink] [NRFJPROG][nRF52][] Access protection is enabled, can't read device version.
09:45:41.209	Using @nordicsemiconductor/nrf-device-lib-js to communicate with target via JLink
09:45:41.209	JLink OB firmware version J-Link OB-nRF5340-NordicSemi compiled Dec 3 2021 15:46:49
09:45:41.212	Device family NRF52_FAMILY
09:45:41.212	Device version UNKNOWN
09:45:41.213	Board version PCA10040
09:45:41.214	Loading readback protection status for Application core
09:45:41.220	[nrfdl][info](09:45:41.215) Loaded plugin C:\Users\Bret Foreman\AppData\Local\Programs\nrfconnect\resources\app.asar.unpacked\node_modules\@nordicsemiconductor\nrf-device-lib-js\Release\nrfdl-jlink-plugin.nrfdl, starting to resolve symbols
09:45:41.425	[nrfdl][error](09:45:41.425) [jlink] [NRFJPROG][DebugProbe][] Failed reading device info.
09:45:41.425	[nrfdl][warning](09:45:41.425) [jlink] [NRFJPROG][DebugProbe][] Warning: Could not read device info because the device is locked.
09:45:41.425	[nrfdl][warning](09:45:41.425) [jlink] [NRFJPROG][DebugProbe][] Warning: No actions other than recover will be available.
09:45:41.425	[nrfdl][warning](09:45:41.425) [jlink] [NRFJPROG][DebugProbe][] Warning: Try recovering the device if you want to unlock it.
09:45:41.431	[nrfdl][error](09:45:41.428) [jlink] [NRFJPROG][nRF52][] Access protection is enabled, can't read device version.
09:45:41.610	[nrfdl][info](09:45:41.610) close plugin dll at path: C:\Users\Bret Foreman\AppData\Local\Programs\nrfconnect\resources\app.asar.unpacked\node_modules\@nordicsemiconductor\nrf-device-lib-js\Release\nrfdl-jlink-plugin.nrfdl
09:45:41.610	Readback protection status: NRFDL_PROTECTION_STATUS_ALL
09:45:41.614	Parse memory regions for Application core
09:45:41.617	Update files regions according to Application core
09:45:41.617	Parse memory regions for file
09:45:41.620	Device is loaded and ready for further operation
09:45:45.262	Recovering NRFDL_DEVICE_CORE_APPLICATION core
09:45:45.271	[nrfdl][info](09:45:45.262) Loaded plugin C:\Users\Bret Foreman\AppData\Local\Programs\nrfconnect\resources\app.asar.unpacked\node_modules\@nordicsemiconductor\nrf-device-lib-js\Release\nrfdl-jlink-plugin.nrfdl, starting to resolve symbols
09:45:45.461	[nrfdl][error](09:45:45.462) [jlink] [NRFJPROG][DebugProbe][] Failed reading device info.
09:45:45.461	[nrfdl][warning](09:45:45.462) [jlink] [NRFJPROG][DebugProbe][] Warning: Could not read device info because the device is locked.
09:45:45.461	[nrfdl][warning](09:45:45.462) [jlink] [NRFJPROG][DebugProbe][] Warning: No actions other than recover will be available.
09:45:45.461	[nrfdl][warning](09:45:45.462) [jlink] [NRFJPROG][DebugProbe][] Warning: Try recovering the device if you want to unlock it.
09:45:45.468	[nrfdl][error](09:45:45.464) [jlink] [NRFJPROG][nRF52][] Access protection is enabled, can't read device version.
09:45:48.721	Recovering NRFDL_DEVICE_CORE_APPLICATION core completed
09:45:48.723	Device recovery completed
09:45:48.724	Using @nordicsemiconductor/nrf-device-lib-js to communicate with target via JLink
09:45:48.724	JLink OB firmware version J-Link OB-nRF5340-NordicSemi compiled Dec 3 2021 15:46:49
09:45:48.725	Device family NRF52_FAMILY
09:45:48.726	Device version UNKNOWN
09:45:48.727	Board version PCA10040
09:45:48.727	Loading readback protection status for Application core
09:45:48.728	[nrfdl][info](09:45:48.722) close plugin dll at path: C:\Users\Bret Foreman\AppData\Local\Programs\nrfconnect\resources\app.asar.unpacked\node_modules\@nordicsemiconductor\nrf-device-lib-js\Release\nrfdl-jlink-plugin.nrfdl
09:45:48.728	[nrfdl][info](09:45:48.728) Loaded plugin C:\Users\Bret Foreman\AppData\Local\Programs\nrfconnect\resources\app.asar.unpacked\node_modules\@nordicsemiconductor\nrf-device-lib-js\Release\nrfdl-jlink-plugin.nrfdl, starting to resolve symbols
09:45:49.285	Readback protection status: NRFDL_PROTECTION_STATUS_NONE
09:45:49.285	[nrfdl][info](09:45:49.285) close plugin dll at path: C:\Users\Bret Foreman\AppData\Local\Programs\nrfconnect\resources\app.asar.unpacked\node_modules\@nordicsemiconductor\nrf-device-lib-js\Release\nrfdl-jlink-plugin.nrfdl
09:45:49.285	[nrfdl][info](09:45:49.286) Loaded plugin C:\Users\Bret Foreman\AppData\Local\Programs\nrfconnect\resources\app.asar.unpacked\node_modules\@nordicsemiconductor\nrf-device-lib-js\Release\nrfdl-jlink-plugin.nrfdl, starting to resolve symbols
09:45:49.804	[nrfdl][info](09:45:49.804) close plugin dll at path: C:\Users\Bret Foreman\AppData\Local\Programs\nrfconnect\resources\app.asar.unpacked\node_modules\@nordicsemiconductor\nrf-device-lib-js\Release\nrfdl-jlink-plugin.nrfdl
09:45:49.807	Parse memory regions for Application core
09:45:49.808	Update files regions according to Application core
09:45:49.808	Parse memory regions for file
09:45:49.811	Device is loaded and ready for further operation
09:45:56.908	Parsing HEX file: C:\Nordic\SDK_17.1.0\examples\ble_peripheral\ble_app_hrs\hex\ble_app_hrs_pca10040_s132.hex
09:45:56.916	File was last modified at 12/8/2022, 9:19:12 AM
09:45:56.989	Update files regions according to Application core
09:45:56.989	Parse memory regions for file
09:45:56.989	SoftDevice detected, id 0x101 (S132 v7.2.0)