Hi We have an application where we what to read i2c sensor data over the air to an iPhone. We've taken ble_app_uart_S130 project and grafted in some twi_hardware code. There...
I am interested in the S130 ability to hold 3 central -> peripheral links over BLE, and am looking for some evidence that this has been accomplished with extremely low-power...
I'm trying to implement channel scanning in our nrf24lu1p based USB dongle.
I'm following the specs and basically loop though each channel ;
loop
stop listening
set...
Hi,
I am using the NRF8001 in UART mode and attempting to bond with my android device (Lollipop 5.0 Nexus 6).
i am using the nordic arduino sdk which is found here:...
Hi, I'm using the nRF8001 in an application that requires security so bonds to the remote client/central. My device supports firmware upgrades that may involve new nRF8001...
Hello.
Initially when reading the Gazell documentation I didn't think it'd be a problem but now in Keil seeing this has introduced some doubt whether it's a thing:
...
Hello,
Considering the waveforms in the following chart, which will be the best approach to keep the power consumption as low as possible?
Specifically, which peripheral...
Best regards:
I have one PTX and one PRX, both nRF24L01+ with PA and LNA. PTX send 4 bytes to PRX but PRX doesn't get RX_DR, and PTX fire MAX_RT.
PRX:
PTX:
...
Hi
I had a strange error when I Set up a project in Segger, I got TRUSTED EXECUTION NONSECURE error.
I was trying to build the project for thingy:91 with nrf Connect SDK...
Good day;
I read the relevant posts. But I'm confused and do not understand.
1. What is the best way to identify the requesting device? Its specification identify is unique...
Hello
I want to set up the SEGGER Embedded Embedded Studio and I'm at the stage where I should select the board directory.
The Getting started Assistant shows an example...
Hi
in nRF9160, there are several AT commands to measure/handle battery voltage: examples:
%XVBAT
%XVBATLVL
Which PIN do they sense? are they VDD1 & VDD2 (which I believe...
Hi,
I am currently developing a health monitoring device. I would like to know if the nRF9160 is certified to be used with the LTE network in Canada. I am interested more...
Hi,
Recently we have bought nRF9160 DK PCA10090 devices and tried to add to nrf cloud account but we end up with issues.
Following the standard procedure mentioned in...
Hello,
I noticed that when my Thingy is charging the Temperature measured is 4°C higher
The data are coming from NRF Cloud.
We can clearly see the temperature rising...
I use SDK16.0.0 and SD7.0.1-S132 Implement NUS functions, 1 * ble_central and 6 * ble_peripheral. The uart of ble_central connect to STM32MCU. My system run as follows, 6...
Hi. I tried to add rel_humidity_measurement cluster to multisensor example. New cluster is visible , but i cant get humidity data report I used cli exemple, here are logs...
Hello,
We have studied the getting started guide for the OTA upgrade at the link below.
https://devzone.nordicsemi.com/nordic/short-range-guides/b/software-development...
Hi all,
I was trying to evaluate the nRF52840 current consumption through the online power profiler. I set the tool as in the below image
there are three standby currents...
Hello guys,
I am attempting to send AT commands to an nrf9160 over UART. I started by loading the serial_lte_modem sample and sending commands using the LTE link monitor...