Hi,
When creating and adding an characteristic to service, what the meaning and difference between these two variables:
attr_char_value.init_len
attr_char_value.max_len...
Hi all,
I have compiled the ble_app_hids_keyboard example for a nRF52832 on a Laird DVK-BL652 breakout board.
I have a tablet running android 5.1.1 and the nordic nRFConnect...
Hello All,
We are using nrf52840 board interface with wiznet550i.
We try to implement mqtt tls 1.2.we get following errors..
I get certificate verification error -0x2700...
Hi,
i am using SDK v8 with softdevice v8,using master control panel pc application,added custom service and characteristics to application,problem is characteristics value...
There is the board mark on the chip like n51822CEAAD01350A0, where DO is Build code, 1350 is tracking code(YYMM), A0 is lot code.
My question is how can I get those codes...
I'm trying to debug a randomly occuring Hardfault. In trying to trace down the source I read the CPU registers use the Nordic hardfault_implementation.c which grabs the register...
Currently i was using arduino for my development but now i want to move forward with Some SOC so i found nrf51822 IC.For using nrf51822 ic i need to buy another board which...
I would like to use the nRF24L01+ for a telemetry project that requires broadcast at 100% duty cycle at a fixed bitrate. Ideally, we could also use our own frame format. ...
I am trying to use whitelisting and a passkey to add security for my application. So far I have the passkey set up so that it is working on the master control panel on PC...
Dear sir.
From [nRF51_Series_Reference_manual], ADC maximum input voltage has two rules.
The ADC should not be exposed to higher voltage than 2.4 V on an AIN pin...
hi
i have one custom service that have 6 characteristics
when in android i want to write in one of characteristics it take about one sec .
is this for having 6 characteristic...
In the Androir master control panel app, in the scanner results there is a 'Type:' line for each device. Most of them around me say 'UNKNOWN' however some say 'BLE only'....
SDK 11.0.0, S132 v2.0.0, nRF52.
I have searched through the many questions already on the dev zone on this topic, but cannot solve my problem. I tried adding the dfu service...
hello all,
i am a begineer to nordic . i am trying to read adc PCF8591 value through TWI and i want to print the value in UART TERMINAL.
i have written the code. but...
Hi,
Im trying to connect ble_app_uart to my gsm module. For some reason program fails at runtime. I was expecting to find a filename and line number where the error has...
Hi,
nRF52 Board, S132. Now, I want 6 pwm, 6 adc .
nRF52 has 5Timers, Timer0-Timer4.
Now, I allocation these timers as follows:
//TIMER0 is used by softDevice
APP_PWM_INSTANCE...
Hi,
I want to access restricted peripheral: TIMER0.
After small research found that I should use sd_ wrappers, in my case sd_nvic_SetPendingIRQ(TIMER0_IRQn) however I...
Greetings,
I'm working with LPCOMP to detect a signal. This signal is the output of an opamp amplifier. What is happening is that when the LPCOMP is switched on there are...
Hi,
I am using SHT21 Temp sensor via TWI manager. As per the spec shown in the image
I have to add 20us delay between the sensor ACK and STOP command.
Is there any...
Hello, I have the Beacon Development board and the sample firmware downloaded and up and running in the Keil MDK IDE. My specific application requires some code to execute...
Hi,
i want to add a current time service to nRFgo. In particular for the glucose measurement profile.
Any suggestions for this???