There is the board mark on the chip like n51822CEAAD01350A0, where DO is Build code, 1350 is tracking code(YYMM), A0 is lot code.
My question is how can I get those codes...
I'm trying to debug a randomly occuring Hardfault. In trying to trace down the source I read the CPU registers use the Nordic hardfault_implementation.c which grabs the register...
Dear nordic employee
my purpose is send a data the length is from 150 to 273
when my server device send data by sd_ble_gatts_hvx(the send length is fixed 10 bytes) ...
Dear nordic employee:
The service I want to find is the sound service of the thing52 thingy sound service
I tried to modify the HRT_central_client project to find the...
When I was using the device as peripheral, I was wondering when the Softdevice notified BLE_GAP_EVT_SEC_PARAMS_REQUEST and BLE_EVT_SEC_INFO_REQUEST:
1, when peripheral...
hi dear nordic employee:
I tried to build the project ble_app_hrs_c(pca10040) by keil5
but I get an error :
._build\nrf52832_xxaa.sct(7): error: L6236E: No section...
Hi,
I am a bit confused about power consumption when using app_uart_fifo. To save power I put MCU to sleep in between each sent and received byte by using __WFE and __SEV...
Dear ladies and gentlemen,
There is not much information about the RESET pin in the datasheet. I guess, it doesn't have an internal pull-down resistor, but when I look at...
Hi,
I have a problem configuring readback protection using boot.
It seams that the BOOTLOADER stops when trying to read some information from the softdevice if readback...
HI:
i want to use peripheral and central function.and i can switch it to work peripheral or central state when i need.which stack should i use.s120 or s130.
I am using CMSIS RTOS (RTX) to implement an application for the NRF52 DK. I have found an error in the SVC handler that results in a hard fault when calling a soft device...
Hi all,
I was trying to use the S130 Softdevice but the uart peripheral doesn't work properly... I am trying to send three bytes, but only one appears. Flow Control doesn...
I am using a mutex to protect a serial debug printout.
Is it safe to use sd_mutex_acquire in a blocking manner, provided it is only called from main and softdevice callbacks...
As suggested in another post , I asked to our Nordic dealer about nRF52832 chip availability.
Thay talk about 2015 december for mass production , as your direct info confirm...
When i setup DEVICE_MANAGER_MAX_BONDS in 2 and trying to connect third device the nRF 51422 (10028) is freezing and all LED's light up. Why the algorithm in "device_manager_evt_handler...
Hi
I managed to integrate the buttonless DFU example, but while testing it, I have a few difficulties.
I use Lightblue to access my services and enable notifications...
Hello There, I want to connect two slaves to my nRF51422 PCA10028. I came up with the idea of using two master communications which share MOSI AND MISO but have different...
Can the chip be updated from an ANT device to a BT Smart Central. This means it starts its life with an S210 and then gets a serial code update to an S120. Obviously with...
Hi,
I'm testing writing and reading at one of my characteristics in Master Control Panel v.3.7.1 (SoftDevice S110 v7.1.0). As shown in the following figure, firstly I've...
Reading from the FICR seems to produce some results other than what I would expect. For example, reading from offset 0x10C seems to return the flash size (instead of 0x110...