Hello!
We are planning to purchase an electronic component nrf52840 and produce a finished product on it.
question
1. Will it work immediately on the ZIGBEE 3.0...
Good morning, I have a question about NRF Util. I need to make some changes in souce code of nrfutil for my own needs, but the most recent version, which is provided on Github...
Hi. I interested now for direction finding in nrf52 series. I have nrf52811, nrf52833 and other controllers. But i don't find any information how develop board for recievers...
Zephyr Eddystone example is connectable after power on of nrf52833 board. But after disconnect it becomes non connectable. How to fix it? And how to change advertisement interval...
We are looking for an experienced software developer, for existing board with using nRF Connect SDK. We are using nRF52840-dk.
Please, contact me if you are interested.
i use s110 send notification to s120,and set connect interval with 7.5ms,but in actually the connect interval is 15ms!!I see s120 softdevice specification,s120 as client which...
Hi,here i met an issue that when i set address type in public mode by funtion sd_ble_gap_address_set(),and then the advdata packet data was all zereo.This project was created...
Dear ladies and gentlemen,
There is not much information about the RESET pin in the datasheet. I guess, it doesn't have an internal pull-down resistor, but when I look at...
Hi,
I have a problem configuring readback protection using boot.
It seams that the BOOTLOADER stops when trying to read some information from the softdevice if readback...
HI:
i want to use peripheral and central function.and i can switch it to work peripheral or central state when i need.which stack should i use.s120 or s130.
I am using CMSIS RTOS (RTX) to implement an application for the NRF52 DK. I have found an error in the SVC handler that results in a hard fault when calling a soft device...
Hi all,
I was trying to use the S130 Softdevice but the uart peripheral doesn't work properly... I am trying to send three bytes, but only one appears. Flow Control doesn...
I am using a mutex to protect a serial debug printout.
Is it safe to use sd_mutex_acquire in a blocking manner, provided it is only called from main and softdevice callbacks...
As suggested in another post , I asked to our Nordic dealer about nRF52832 chip availability.
Thay talk about 2015 december for mass production , as your direct info confirm...
When i setup DEVICE_MANAGER_MAX_BONDS in 2 and trying to connect third device the nRF 51422 (10028) is freezing and all LED's light up. Why the algorithm in "device_manager_evt_handler...
Hi
I managed to integrate the buttonless DFU example, but while testing it, I have a few difficulties.
I use Lightblue to access my services and enable notifications...
Hello There, I want to connect two slaves to my nRF51422 PCA10028. I came up with the idea of using two master communications which share MOSI AND MISO but have different...
Can the chip be updated from an ANT device to a BT Smart Central. This means it starts its life with an S210 and then gets a serial code update to an S120. Obviously with...
Hi,
I'm testing writing and reading at one of my characteristics in Master Control Panel v.3.7.1 (SoftDevice S110 v7.1.0). As shown in the following figure, firstly I've...