Seeing recent response to my original question on multiple chip selects, I've opted to share a modification to spi_master that I've implemented in part to make handling some...
What is the official status of the Softdevice Serialization for S130 in SDK 9? I could see an older answer on how that was removed in SDK 8 but since almost half year has...
Hi
The documentation for the new feature in S110 v8 to change the gatt table size says that to change it the linker configuration needs changing .
This means it is a...
I used to be able to see my development kit in nRFgo studio and flashed S110 onto the chip. Now all I see is: "No boards connected". I am still able to flash programs onto...
Hello,
I have an iOS application communicating with a custom device having a nordic 8001 chip.
They have established a bonded relation. In nRFgo Studio, in Security...
Hi there, thanks for your help in advance!
I have tried the nrf51-ble-ancs-nus sample from github and making it work on a 51822 EK board, i.e., it can receive notifications...
I try to use hcidump, capture CSR dongle on ubuntu14.4.
I can find SDK8.1.1 s110 keypad demo create connection fail.
HCI Event: Command Complete (0x0e) plen 4
LE Set...
SAADC can't measure input voltage higher than VDD voltage. External battery (18650) voltage is higher than on-board VDD. There is very good article on your site explaining...
HI All
Im newbe in on that "field", so im apologize for stupid question.
I will like to check a optimal casing for my new product equiped with bluetooth comunication....
Hi,
I'm having trouble writing a long characteristic. I'm using the pc-ble-windows code from https://github.com/NordicSemiconductor/pc-ble-driver . I've compiled this and...
Hi,
I am using SDK15.2/3, I know the SDK peer manager has a feature to delete the oldest bonds if the flash memory is not enough to store a new bond. In this case, whether...
I want to transfer some data stored in nRF51822 to another BLE central device. I guess the idea is very similar to "ble_app_uart" example except that I don't need the part...
Hi. I have a project based on multi-link central with NUS service.
I can connect to multiple peers ok at the same time, disconnect etc. However if I am connected to one...
The Declaring attributes section of Zigbee stack API overview ( https://infocenter.nordicsemi.com/index.jsp?topic=%2Fcom.nordic.infocenter.thread_zigbee.v3.0.0%2Fusing_zigbee__z_c_l...
Interfacing to CC3100 and need to send socket data over spi that is 1400 bytes.
Assuming I would need to send 200 bytes X 7 and try to get the list array to work.
But...
I thought I had the logging figured out but when I try to develop the application, I always seem to end up with the same error.
I don't understand what causes this and thought...
Hi Experts!
I read some posts related to current measurement, and i have a question.
if SB9 is not opened, current consumption is increased??
i have a Source Measurement...
SDK 15.2 API 6.1 SES
I am trying to read manufacturer data. I know i am advertising it because i can see it on the nRF connect app on my phone. When i try an dparse the...
I'm trying to send data string from Central to Peripheral device using NUS.
If string length exceed 20 bytes then function return err_code = 12 (NRF_ERROR_DATA_SIZE).
...
I have some test code that uses VLOC_USER and when i write with authorization the data seems to get scrambled.
when i use
p_evt_write->data[0];
to get the data it is...