What is the official status of the Softdevice Serialization for S130 in SDK 9? I could see an older answer on how that was removed in SDK 8 but since almost half year has...
Hi
The documentation for the new feature in S110 v8 to change the gatt table size says that to change it the linker configuration needs changing .
This means it is a...
I used to be able to see my development kit in nRFgo studio and flashed S110 onto the chip. Now all I see is: "No boards connected". I am still able to flash programs onto...
Hello,
I have an iOS application communicating with a custom device having a nordic 8001 chip.
They have established a bonded relation. In nRFgo Studio, in Security...
Hi there, thanks for your help in advance!
I have tried the nrf51-ble-ancs-nus sample from github and making it work on a 51822 EK board, i.e., it can receive notifications...
I try to use hcidump, capture CSR dongle on ubuntu14.4.
I can find SDK8.1.1 s110 keypad demo create connection fail.
HCI Event: Command Complete (0x0e) plen 4
LE Set...
I want to experiment with recording observations of the beacons with raspberry pi's.
Is there any precompiled firmware I can install on the nRF51822 smart beacon...
Hello, I want to program and debug the nrf52840 device but I'm kind of stuck at the programing range/address issue.
I'm using my customized board so I doubt Nordic Semi...
First I register the address of the central device to the peripheral device. When I work with a single peripheral device and a single central device, I can send commands from...
I'm trying to understand the subtleties in a Gazell link setup with multiple devices and a single host.
The documentation in the infocentre suggests minimum timeslot_period...
Hi,
Just wanted to confirm what the average current measured by the PPK represents. So for example if I have AVG in average window as 2.5mA, is that only the BLE (i.e....
Hi,
I found a bug in ble_app_gls example from SDK_12.3.0 / s130.
If user enters a wrong passkey, the app ends in a app_error_fault_handler exception and the central keeps...
I think I found the source of many of my recent problem. The print in Segger is going crazy.
I found out that if I increment a simple variable and print it when I hit debug...
Hi,
I am using the nRF52-DK as a device like beacon encodded with the original code of "nRF5_SDK_13.0.0_04a0bfd\examples\ble_peripheral\ble_app_beacon.
I want to change...
I am beginner of 52832. Current software is based S132 4.0.2 and SDK 13.0.0. Test platform is based on PCA10040.0
My problem is application can not start normally in merged...
Hello,
I am using nrf51 and sdk11. I have one code and I am trying ti build hex or bin file for this code. Now the code size exceeds and so I am trying to build using makefile...
I am learning about FPGA. I have question general question related to it.
Doc1.docx
A FPGA is connected to a 14-bit DAC and to an output amplifier. The DAC have a sampling...
Using S132 v4.0.2, is it possible to disable DLE (i.e. make it NOT set the LE Data Packet Length Extension used bit in the LL_FEATURE_RSP)?
Alternatively, is there a way...
experimental_ble_app_multiperipheral_pca10040_s132 connectivity issue.zip
I’m getting an LMP Response Timeout disconnect reason about 50% of the time when trying to get...
Hi guys
I have been working with a nordic ble device (NRF51822) configured as a Beacon. I am implementing an IOS app, using Apple framework " CoreLocation". My goal is...
I'm looking at using an nRF51822 in a Gazell or ESB application. I prefer not to have any softdevice loaded at all.
What is the correct procedure to perform clock calibration...