I'm looking at interfacing a typical Wheatstone bridge sensor to the nRF51822 ADC. This particular sensor only requires a mA or two for excitation and the output fits within...
When use the "nRFBeacons" app to update the info on my beacon the following happens:
Go to update tab.
Select "Connect"
Press "SW2" on beacon and see the LED begin flashing...
I am using s110 and nrf51822. I've set up up a long characteristic of 154 bytes.
Sending between 1 and 154 bytes works as expected.
Sending 155 - 160 bytes gets rejected...
Hi,
I tested the nrf beacon application, it allows only the beacons with company identifier 0x0059 (nordic's id). But i need to modify it to support all the device, how...
I use a app_timer_create() function to create a task(200ms once)
when in the task_timeout_handle() ,
I do something more than 200ms,
what will this timer going ?
This blog was last updated 17.01.2019.
The Bluetooth Special Interest Group (SIG) recently announced the deprecation and withdrawal of Bluetooth Core specifications v4.0 and v4.1. For products that are…
This blog describes how you can setup a Segger Embedded Studio example for PCA10040E (emulating nRF52810) from nRF5 SDK 14.2 to use S132 v5.1.0, instead of S112. The procedure should be similar for the…
A common thing to do is to use the Nordic UART Service for quick prototyping.
Often the example itself is used as a starting point (ble_app_uart). But sometimes we use other starting points, and want to…
This project was originally made in an outdated version of NCS, but it has now been updated to NCS v1.5.0. The instructions are the same as before, but the code is different.
Disclaimer: This is a student…
Purpose
This document will show how to automate the provisioning process for Nordic BLE Mesh nodes using Python scripting. When provisioning nodes using PyACI (Python Application Controller Interface)…
I implemented parts of the BLE-MIDI service along with a small example application. I wanted to share it here on the blog, in case someone would find it useful. The intended audience is primarily someone…
This getting started guide is meant as a more detailed practical guide for the Thread Secure DFU Example found on Infocenter which demonstrates upgrade of firmware over the air (OTA). For any questions…
This getting started guide is meant as a more detailed practical guide for the Zigbee OTA (Over the Air) Upgrade Client Example found on Infocenter. If you have any questions regarding Zigbee or Zigbee…
This tutorial uses an outdated version of nRF Connect SDK.
We recommend using the latest version of nRF Connect SDK when getting started with development.
Please see academy…