Hi,
My android Proximity application fails on service discovery only for the very first time it connects with the devices(nrf51822 evaluation kit with sdk 5.2.0). Actually...
Has anyone converted the app note AN34 DTM Python script to C# or C/C++ ?
The Python DTM script is works OK with the setup specified in the app note AN34 figure 2, which...
Hi,
I have a serious problem, when I use uart of NRF51822 QFAAC0 to receive data from another MCU, I found that it will lost one bit at same position everytime. my SDK is...
Hi,
I just started to interface the lcd display with nrf51822 evaluation board. The display i'm using is, spi compatible, 18" tft (160x130) from tiny lcd. I took spi master...
Hi,
We are using the nRF905 device in an application where it needs to switch between auto-retransmitting and sending single packets, due to it communicating with several...
This is not a real question for support. It's more a success story i'd like to share with you!
Our company develops firmware for various customers on a lot of different...
We have a heavy duty scan based application being built on top of the nRF51822 SOC. We have tested the scan function (S130 SD) on both a custom PCB and also the Nordic Smart...
Hi,
I have PCA10028 board, and I'm trying to implement UART send/receive.
I've searched for the problem here but could not find a solution for it.
My uart init function...
Hi
I'm using Keil V5 to program the Nordic nRF51 DK ( the one here: www.nordicsemi.com/.../nRF51-DK) but I'm a bit confused as to whether or not I need to change the settings...
I am not quite certain what the advantages/disadvantages are of using LDV vs DCDC if you are using an external regulator. In my case i use a LiPo battery outputting ~4.2V...
In the ant-to-ble bridge example in the 7.x.x SDK, there is the following comment in examples/multiprotocol/experimental_ble_ant_app_hrm/main.c :
// Need to close the ANT...
Hi all,
As I know in constant latency mode, both the regulators (1v7 & 1v2) and HFCLK are kept on. Is there a way to keep the HFCLK on while one or both the regulators...
Follow up this image. I want to reduce the negotiation time.
10:44:43.655 --> Connected to D6:9E...
10:44:45.123 --> Services Discovered
= 45.123 - 43.655 = 1.468...
when i test the ancs example application for nrf51822, i foud a question : after i disconnect the lightblue ios app with nrf51822 peripheral, the iphone still connected with...
I downloaded ble_app_lbs from GitHub. Loaded the project (on GitHub it was saved as a MicroVision 4 project) into MicroVision 5 and build with no errors or warnings.
I...
Hi sir
I want to combine heart rate, proximity and uart(proprietary) projects to one project.
As your experience, is it possible? Any side effect for that? Thanks.
J...
I have an NRF51 board running as a GATT server. Using an iOS application (LightBlue) I connect to the NRF51. If I quit the iOS application then I get a disconnect event and...
Hi guys,
I got some questions with HID over GATT on iOS/Android:
Does iOS/Android handle Telephony usage input (e.g. for phone pickup/decline)? If not, is there...
Hi I am using nRF6700 motherboard .
But when I want program nRFmodule on board1
error occure:
And I also try Module-nRF51822
There is nothing in "segger to use"
...
After I upgraded to SDK9.0. The old files still left in the project folder. I had this situation last time. What I did was recreated the project.
But is there a better way...