Hi
We are developing software for the nRF51 with Keil under VirtualBox. Previously we used the PCA10000 dongle with the Master Emulator and MCP without issue. Now, with...
We are using nRF51822 for our products.
We want to know the min value of "Receiver sensitivity" when we use this chip for BLE.
The Datasheet says "Receiver sensitivity...
Dear
The BLE Multi-link example (ble_app_multilink_central and ble_app_multilink_peripheral)
shows how one central device can connect to multiple peripheral devices. ...
In the MCP app, if I have the following service data for an Eddystone beacon:
0x10, // Eddystone-URL type
0x00, // TX power in dBm. This is a signed integer so 0xEE ...
I have the nRF Control Panel Android application. It works fine with several BLE devices, but specifically for the Fitbit Flex, it fails to connect.
I know Fitbit wristbandes...
Hi,
The situation:
I was able to successfully receive known packets from a device running gzp_device_dynamic_pairing, from, the host running the gzp_host_dynamic_pairing...
Hi everyone
nrf51822,softdevice s130 2.0.0
now i used softdevice s130 establish two connection as a central with two s110 peripheral device,at the same time i establish...
I am wondering how to precisely measure my power consumption. Till now, I have been using INA216 on PCA10004 board + labView for acquisition, but it is not precise enough...
I was working my way through the app note nAN-36, where it says you should have a seperate source and header file for each service. However in many of the newer SDK examples...
New to embedded world. Trying to interface MPU6050 w/ nRF51 DK via TWI. I have included the external MPU6050 drivers and everything compiles in Keil (except for last few lines...
I will be building PCBs with an nRF51822 module. I was reading in another question that perhaps the best way to program the nRF51822 on multiple PCBs is to use the SEGGER...
The nRF51822 softdevice is generating the following disconnection event:
11:20:09.363365 : BLE_GAP_EVT_DISCONNECTED c=x05dd
11:20:09.365011 : reason = x002a
11:20:09...
The Health Device Profile is continua compliant. Are BLE health related profiles like Heart rate profile, thermometer profile continua compliant as well? Do these profiles...
Hello, I was wondering what the proper process is to set the measured RSSI values at 1 meter is. RSSI at 1 meter is a part of the iBeacon standard, and is also useful for...
I am PHD student in china and doing research about gait retraining. I am designing wearable sensor that monitoring gait and giving vibration feedback to retrain the gait and...
I've implemented my DFU app on Android(4.3). During the test, I found a strange problem, that the performance of writing image data into swap area is very very slow. My Softdevice...
Hi
I thought: let us quickly migrate to the latest SDK.
But that seems to be harder than anticipated.
I run into a number issues when compiling with the new code:
...
Dear Nordic developers,
I'm trying radio reciever example. I want to stay 7 ms in listening mode, if there is no event turn off the radio. For that I'm using timer interrupt...
When connect to iphone4s, whitelist.irk will be generate,and whitelist.irk_count will be add 1
After that connect to Nexus 7 II bouth irk and addr will be generate,and...
Hello all,
I've had problems for several weeks with RF24 Library (enhanced fork). I use different Arduino and NRF24l01+. I know very well different documentation, and I...