In the MCP app, if I have the following service data for an Eddystone beacon:
0x10, // Eddystone-URL type
0x00, // TX power in dBm. This is a signed integer so 0xEE ...
I have the nRF Control Panel Android application. It works fine with several BLE devices, but specifically for the Fitbit Flex, it fails to connect.
I know Fitbit wristbandes...
Hi,
The situation:
I was able to successfully receive known packets from a device running gzp_device_dynamic_pairing, from, the host running the gzp_host_dynamic_pairing...
Hi everyone
nrf51822,softdevice s130 2.0.0
now i used softdevice s130 establish two connection as a central with two s110 peripheral device,at the same time i establish...
Hello , I want use nrf24lu as "Hos" and nrf51822 as 'Device'.
I need some info about nrf24xx whith gazell .but I can't find info bout those param like:
typedef enum...
When you download win driver (from www.nordicsemi.com/.../72324929 for instance). There's only a win32 dll/lib provided.
However, modern development are often made on 64bits...
how to change the twi sensor coding to get the X,Y,Z AXIS for the position of the gy-80 module
this module has
1. HMC5883L
2. BMP-085
3. L3G4200D
4.ADXL345
at...
Hello,
I would like to append data to a coap response like this:
I have a response handler that is triggered as the device receive the response. I am able to get the...
Hello guys,
I am trying to run the mqtt_simple sample. I tried to do so on both nrf9160_pca10090ns and nrf9160_pca20035ns. The application builds fine for both boards...
Hi,
Does nRF52840 on Thingy 91 and nRF9160 DK has a unique MAC-address? Or is it a randomized MAC-address with a high probability of being unique in the user's environment...
Hi,
Is there a way for the application layer to be aware of what the modem Tx power is? We would like to know for purposes of warning customers if they have placed a device...
I know that as per definition the connection interval is the time between two connection events.
So does it mean that if the connection interval duration is low then number...
Hey guys,
I have nRF52840-DK and one time i got pop-up from nRFgo Studio, that i need newer version of Jlink. I updated Jlink from Segger website to version 6.62b. After...
To the kind attention of Nordic support team,
Is it possible to change pipes' numbers used by secured gazell library? It seems to be using pipe0 for pairing infos and pipe1...
Hi, I have a quick question regarding the DFU MTU get request.
According to the docs page , this should return the MTU used by the transport, but in reality nothing is transmitted...
Hi,
nRF9160 DK (PCA10090) is continuously rebooting.
I have flashed following Images and tested, but same issue (rebooting continuously) observed.
1. Pre-compiled...
Hi,
I try to build and programm Thing:91 with segger embedded Studio and need the file app_signed.hex to Flash the Firmware in Thing:91 without a external debug probe. After...
Hello
I have a 3 custom PCBs with nRF52832 (1 central and 2 peripherals) and 1 nRF51 dongle (peripheral) arrangement where the two peripheral nRF52832 boards (custom PCBs...
I have just switched from SDK version 1.0.0 to SDK 1.1.0 and I am using the MQTT FOTA example
I had the example project working when I was using v1.0.0 of the SDK
I...
Hello,
I am using nRF52840, SDK_16.0.0, SoftDevice S140 V7.0.1 and Segger for flashing the image. I am using ‘ble_app_blinky’.
1) Do we need to call fds_record_close...
Hello everyone!
I tried to write data directly into flash using flash manager from nrf SDK, but according to docs it does not work with ble mesh.
But mesh flash manager...