I'm having some issues regarding the data update interval when running the asset_tracker_v2 application, particularly with adjusting how frequently it publishes data to the...
Dear Nordic,
it's about USB implementation. We need to add interface string descriptor for ineterface name. Using USBD_STRING_DESCR_DEFINE(primary) I've added that to string...
Hello, I have NRF D 24LU1P 1201FD and NRF F 24LU1P 2136IW. The first one executes all commands, while the second one does not work for writing and erasing. I tried to erase...
Hi! Could you clarify a bit about Bluetooth mesh gateways' implementations. I wonder to know possible ways of Bluetooth mesh gateway implementations. How is it possible right...
Hi everyone.
I catch a terrible issue
When I use nrf52840 and NUS Android app and had for a short time a bad rssi (because of long distance between Android and SoC) and...
Hello
We need to scan for more than 8 devices, so we can't use witelist directly.
We have an idea to use presaved IRK and mac-addresses and use scanning without witelist...
Hi,
Does nRF52840 on Thingy 91 and nRF9160 DK has a unique MAC-address? Or is it a randomized MAC-address with a high probability of being unique in the user's environment...
Hi,
Is there a way for the application layer to be aware of what the modem Tx power is? We would like to know for purposes of warning customers if they have placed a device...
I know that as per definition the connection interval is the time between two connection events.
So does it mean that if the connection interval duration is low then number...
Hey guys,
I have nRF52840-DK and one time i got pop-up from nRFgo Studio, that i need newer version of Jlink. I updated Jlink from Segger website to version 6.62b. After...
To the kind attention of Nordic support team,
Is it possible to change pipes' numbers used by secured gazell library? It seems to be using pipe0 for pairing infos and pipe1...
Hi, I have a quick question regarding the DFU MTU get request.
According to the docs page , this should return the MTU used by the transport, but in reality nothing is transmitted...
Hi,
nRF9160 DK (PCA10090) is continuously rebooting.
I have flashed following Images and tested, but same issue (rebooting continuously) observed.
1. Pre-compiled...
Hi,
I try to build and programm Thing:91 with segger embedded Studio and need the file app_signed.hex to Flash the Firmware in Thing:91 without a external debug probe. After...
Hello
I have a 3 custom PCBs with nRF52832 (1 central and 2 peripherals) and 1 nRF51 dongle (peripheral) arrangement where the two peripheral nRF52832 boards (custom PCBs...
I have just switched from SDK version 1.0.0 to SDK 1.1.0 and I am using the MQTT FOTA example
I had the example project working when I was using v1.0.0 of the SDK
I...
Hello,
I am using nRF52840, SDK_16.0.0, SoftDevice S140 V7.0.1 and Segger for flashing the image. I am using ‘ble_app_blinky’.
1) Do we need to call fds_record_close...
Hello everyone!
I tried to write data directly into flash using flash manager from nrf SDK, but according to docs it does not work with ble mesh.
But mesh flash manager...
Hi to everybody,
there's a way to force a Zigbee router device to send Announcement Command at certain time interval also if it's already joined to a network?
I saw that...
There are two capacitors (C18, C27) that are labeled as N.C./Not mounted but there is no description for their existence at all. Do I need to place those pads?