I am a started guy.
I only need a bluetooth device (BLE) to check the signal and mac address.
What is the best choice?
I need the smallest and low powered!
Thank you...
I am working on code to setup a bond manager for ancs based off of the example, but have a fixed advertising and connection interval of 25ms. How does the bond manager and...
Hello,
We have experienced odd problem, we are not able to scroll up or down SDK documentation at these pages on Android devices. IPHONE browser Safari works ok. Any help...
HI,ALL!
I tried to add a RTC wakeup funtion to my ble device, so i add the code of the Nordic board example named "rtc_example" to my program.
But it turned out that my...
Hi,
I'm working on a Keyboard&Touchpad project, very similar configuration with Smart Remote 2, so I'm considering to use nRF24LU1+ as receiver's MCU. The receiver will be...
I am getting random data while using saadc example to reading analog voltage applied to pin on nrf52840. i want to read analog output from MQ135 gas sensor, I have applied...
Dear all,
by looking at the sdk code, specifically that of s132 component, I understand that the length of the PIN code is statically set to 6 and cannot be changed.
...
We have been using nrf24l01+ for sending few bytes between one Master(Master MCU board) device and many slaves(slave MCU boards). Each time Master Device queries data from...
I installed nRFprobe driver to program and debug my nRF24LE1 chip from Keil. I am using a nRFgo 6700 starter kit for flashing and debugging purpose. I connect ISP connection...
Hi.
We are a Norwegian company trying to create a prototype to monitoring people.
We are already waiting our BLE 5 with ANT capabilities to start creating the prototype...
I am having strange behavior with android application/nrf51 pair
I am normally able to connect to my nrf51 device in a second or two with an android app.
however when the...
I could send external data to nRF 52832 and succeeded in sending the data to the mobile from there.
However, probably because the data transmission interval is different...
Hi,
in the reference circuit, I see a value of 12pf for C1 and C2.
In the murata passive components kit a value of 12pf is also stated, but the part number referenced...
I got my developer kit and have been playing around with BLE. But I got my mind set on a solution with several nodes as sensors, and one "base" node connected with an API...
Our customer is asking us to add Ethernet on board.
I want to use as much "off the shelf" stuff Nordic/Keil has provided as possible.
Is there a "typical solution" with...
Hi,
I'm trying to create to create A TCP/IP connection over Bluetooth between an n51x chip and other device (let say an iPhone mobile).
I've seen in the SoftDevice S130...
Hi I am using wireshark 1.10.6, when press 'w' wireshark started but it is not capturing packets. even I select my device then also facing same problem. I waited for some...
why use 50ms and 400ms connection interval for testing the maximum data throughput(2M,247byte payload)?
Because 50ms can only send a pdu , and 400ms can send up to 8 pdu...