Hi,
i am using SDK v8 with softdevice v8,using master control panel pc application,added custom service and characteristics to application,problem is characteristics value...
There is the board mark on the chip like n51822CEAAD01350A0, where DO is Build code, 1350 is tracking code(YYMM), A0 is lot code.
My question is how can I get those codes...
I'm trying to debug a randomly occuring Hardfault. In trying to trace down the source I read the CPU registers use the Nordic hardfault_implementation.c which grabs the register...
Dear nordic employee
my purpose is send a data the length is from 150 to 273
when my server device send data by sd_ble_gatts_hvx(the send length is fixed 10 bytes) ...
Dear nordic employee:
The service I want to find is the sound service of the thing52 thingy sound service
I tried to modify the HRT_central_client project to find the...
When I was using the device as peripheral, I was wondering when the Softdevice notified BLE_GAP_EVT_SEC_PARAMS_REQUEST and BLE_EVT_SEC_INFO_REQUEST:
1, when peripheral...
Hi !
Here my adv setting (slow interval) to advertise every seconds :
#define APP_ADV_INTERVAL_SLOW 0x0664 /** This value corresponds to 1022.5 ms).
#define APP_SLOW_ADV_TIMEOUT...
Just ordered another pair of beacon hardware and noted the nrf chip is now coated in black goop.
Curious as to what this is for, and the reasoning its been added to the...
Hello,
I have a master configured as "Bidirectional Master Channel" and a slave configured as "Bidirectional Slave Channel". Both talk to each other. When I start just the...
Is the DC/DC converter enabled when running ble_app_beacon?
Or is it only the LDO that is enabled?
I am running the application on nRF51822-DK.
BR Magnus
I ran into this last night and curiously, James appears to have posted about it yesterday ( devzone.nordicsemi.com/.../trouble-with-system-halted,but-cannot-reset-nrf51822...
I am trying to get the Heart Rate example in the nRF51 SDK to work (found in ...nrf51822/board/nrf6310/ble/ble_app_hrs). It fails at line 338 in main.c (at the call sd_ble_gap_device_name_set...
I'm putting some bootloader and static config data in the customer section of the UICR and I accidentally wrote to 0x1001200 and worked just fine.
Looking closer, it seems...
Dears:
We will adopt nRF51822 for our project, and we want to confirm with you for the question as below:
Does nRF51822 support HCI command protocol through either...
Hello,
I do erase flash pages in my application I use the sdk api:
nrf_nvmc_page_erase(firstaddress);
nrf_nvmc_write_bytes(address, data, len);
but I did not found...
Hello,
i couldnt find the correct answer yet. I would like to use a RTC and also the s110 and BLE.
I collect data from sensors over i2c and send it over BLE. timing...
My username and password credentials do not work here or on the normal nordic semi site. The random password (i.e. fj[k%3) will work at the nordic semi site, and continue...
Hi,
I am starting development on my project using the ble_app_hrs as a template. This project already has the buttons setup for interrupts using the Button Handler library...