Hi,
I purchased nRF52 DK 2 PCs. PCB labeled
PCA10040
3.0.4
2024.34
boath board are new and box packed. from first time itself. I am not able to flash the board...
Hi everyone.
I cutted PCB track shorting solder bridge SB40 .
I connected like this..
Then I opened power profile kit 2. I am using amperemeter..This is my app scrrenshot...
Nordic Support,
My product uses the nRF52840 chip and nRF52 SDK 17.1. I have a feature request to support hosting multiple peripheral connections, each with a unique advertising...
I am working with NRF52840 with SoftDevice S140 and SDK v17.1.0.
The boot loader address for this chip is 0xF8000. I can set up one of the 'fstorage' module with the address...
Hey everyone,
Does anyone here have experience with firmware OTA updates over the JIO NB-IoT network? The process seems a bit different since JIO Cloud always sits between...
Hello:
The latest nRF54L15 Errata for Rev 2 shows that the previously reported "GPIOs can exhibit radiated emissions" is no longer present in the Rev 2 SoC.
Can you please...
Hi, this is a very broad issue that i am having, because i dont know the source of it. I am simply unable to use the bme68x IAQ library. i have downloaded the external bsec...
I am seeing three things I don't understand in a modified ble_app_rscs codebase. I'm hopeful that someone else can recognize my symptoms and tell me what I'm doing wrong....
I've got a project that works perfectly on the PCA10028 DK. But the behavior is quite different when downloaded to my nRF51822 production target. My target is connected to...
Hi
I use nRF51822 of Gazell mode and RXF2401C(PA)
PA's TXEN has been pulled, what RXEX in there enbale and disable it?
(Host and Device must be)
Thank you!
Hi everyone,
My question is how much current it´s capable to sink an I/O pin configured as output ´0´ ?
In my case I have to discharge a capacitor throught an output...
I am using sd_power_system_off() to enter System Off. It is my understanding that all peripherals are off in System Off, but that GPIO configuration is retained. I have a...
I have the following code
// Initialize timer module, making it use the scheduler
APP_TIMER_APPSH_INIT(APP_TIMER_PRESCALER, APP_TIMER_MAX_TIMERS, APP_TIMER_OP_QUEUE_SIZE...
In the ANT Message Protocol doc, section 7.1.1.1, and in example code, the Device Number is treated as a uint16_t and shown as a two byte field in the flagged extended data...
Hi,
Will something interesting happen when the text segment on a nRF51 DK exceeds 64k? I am using Eclipse/gcc for developing, based on the tutorial provided by Nordic....
Hi,
I am developing a program on a Nordic nRF51 DK, using Eclipse/gcc, and am using J-Link RTT for a debug command line interface. This has worked very well for some time...
Hello,
I've been looking a bit into the nRF52 product specification and I was just wondering how powerful EasyDMA is under extreme conditions.
Let's assume the following...
I am currently working on a device using a nRF905. We want to use the device in Region 2 (USA).
This means that we need to use frequency hopping between 902 and 928 Mhz....
Hi,
I'm implementing a simple bootloader which will not use BLE.
Application will transfer the data from mobile devices using BLE and this data will be stored to...
I'm looking for a smart solution to connect my application to different ANT+ sensors and transmit a logfile to a mobilephone via BT (and receive notifications from mobile...
Hi~ Sir:
I test S120 connect with S110 have problem ,test methods are as follows
S120 connect with S110 ,function ok.
S110 Power Off and On, the interval time about...