Has anyone experience of successful TICK_DV calibration for nRF9E5? What order of accuracy should be achievable?
In my application I maintain a software RTC clocked by...
Hello,
I manage to work with new S310 V2.
I use S310 for hrm only. Saying so also not for DFU service.
I have own proprietary method for transfering application images...
I am working on an application and need to get the exact time that the master node receive advertising from the slave node. I tried with PPI and it's ok to capture the Radio...
Hi, could you please tell me if my assumptions below correct?
Measuring a (ratiometric to VCC) analog signal and selecting VDD_1_2_PS as the reference selecting AIN_NO_PS...
When I initialize the SoftDevice with SOFTDEVICE_HANDLER_INIT(NRF_CLOCK_LFCLKSRC_XTAL_20_PPM, false); // Sets up Crystal Source to 20ppm 32.7628kHz
The project I based...
I am trying to make a product with NRF8002B. I finally have the product prototyped. The user will connect to the device, beep, light up, and track. It will always stay on...
DEVICE_MANAGER_MAX_BONDS is no more than 10.
That means that no more than 10 difference devices (smart phones) can switch the device to DFU mode?? (with boding).
Am I right...
Dear Nordic developer:
I am very eager to have the "Android-nRF-Connect" of the source code! I found the scan and DFU from the "Android-nRF-Toolbox" function, I also need...
Hi
I cannot find the minimum pulse length to trigger wakeup using DETECT from GPIO hw pin configured as SENSE pin in the data sheet for nRF51822.
Ex: set PIN_CNF[0].SENSE...
Hi,
I tried DEVICE_NAME with a AABBC Ddddff Tttttth Vs DEVICE_NAME as AABBC. The time taken to connect with a longer device name takes at least 3 attempts (in the sense,...
Dear Nordic Team,
Thanks for support.
I want to merge softdevice hex,application hex and bootloader hex. I am using windows 7 OS and my SDK version nRF5_SDK_11.0.0_89a8197...
When a nRF52 BLE as peripheral had connected to a BLE device as Central, if the nRF52 BLE also coule connect to other BLE device as Central at the same time with the supoort...
Dear Nordic Team,
Thanks for support.
I try to make zip file generation using command promt as per the nordic document(How to generate the INIT file for the DFU.pdf...
I want to test RF during production but I do not have any GPIO or UART points on my DUT so I don't want to run the DTM. Can anyone tell me what problems there are with this...
Hi:
I reference rate meter program:
“nRF5_SDK_11.0.0_89a8197\examples\ble_peripheral\ble_app_hrs\pca10040\s132_with_dfu”.
After function "device_manager_init",I handle...
HI,
I am now trying to use nrf51_iot_sdk_0.8.0_f1f6187. And I have run example application in nrf51 iot sdk on nrf51-dk board. It works fine.
Now I want to develop on...
I want to send a service changed indicate after upgrading app by dfu.I know dfu already so that,but i don't know that how dfu do that.
there is service_change_indicate...
I used to able to get the blinky example in SDK11 to work. But for some unknown reason I couldn't scan my device using Nordic master control panel. The LED1 will be turned...
Can the nRF52 output the 32.768kHz clock on a GPIO. If so, do I need the 32.768kHz xtal, or can I output the generated clock from the 32MHz xtal? I need this clock to sync...
Hi
Yesterday I downloaded the new SDK12 and checked what changes could be relevant for my ongoing/next projects.
One remarkable thing was the fact that almost any peer...