Hi All,
Please correct the following in my understanding. Also , i am planning to build a
remote controlled device using a PWM output. How does ATT,GATT and GAP affect/influence...
My board works most of the time are very good,but one time i power down the board when ble connecting and data transmitting,the board can't work when power on.and i can't...
Posting this as separate question as it got no traction in the other thread:
Why are there many of the same include files in the DFU example directory as in the S110 7...
Hi all,
this is not a question per se but rather a warning to those who are attempting to debug Flash related operations with the SEGGER J-Link GDB Server (v4.84a for Linux...
I debugging some function abnormal after OTA problem, and problem with disappear after redo OTA FW upgrade, duirng it I found a problem about Master Control Panel FW upgrade...
Hi,
I'm having problems connecting to my device, because whenever I do so, the SoftDevice asserts at address 0x12CFA.
I use softdevice S140 v6.0.0 and SDK v15.0.0.
I...
SAADC can't measure input voltage higher than VDD voltage. External battery (18650) voltage is higher than on-board VDD. There is very good article on your site explaining...
HI All
Im newbe in on that "field", so im apologize for stupid question.
I will like to check a optimal casing for my new product equiped with bluetooth comunication....
Hi,
I'm having trouble writing a long characteristic. I'm using the pc-ble-windows code from https://github.com/NordicSemiconductor/pc-ble-driver . I've compiled this and...
Hi,
I am using SDK15.2/3, I know the SDK peer manager has a feature to delete the oldest bonds if the flash memory is not enough to store a new bond. In this case, whether...
I want to transfer some data stored in nRF51822 to another BLE central device. I guess the idea is very similar to "ble_app_uart" example except that I don't need the part...
Hi. I have a project based on multi-link central with NUS service.
I can connect to multiple peers ok at the same time, disconnect etc. However if I am connected to one...
The Declaring attributes section of Zigbee stack API overview ( https://infocenter.nordicsemi.com/index.jsp?topic=%2Fcom.nordic.infocenter.thread_zigbee.v3.0.0%2Fusing_zigbee__z_c_l...
Interfacing to CC3100 and need to send socket data over spi that is 1400 bytes.
Assuming I would need to send 200 bytes X 7 and try to get the list array to work.
But...
I thought I had the logging figured out but when I try to develop the application, I always seem to end up with the same error.
I don't understand what causes this and thought...
Hi Experts!
I read some posts related to current measurement, and i have a question.
if SB9 is not opened, current consumption is increased??
i have a Source Measurement...
SDK 15.2 API 6.1 SES
I am trying to read manufacturer data. I know i am advertising it because i can see it on the nRF connect app on my phone. When i try an dparse the...
I'm trying to send data string from Central to Peripheral device using NUS.
If string length exceed 20 bytes then function return err_code = 12 (NRF_ERROR_DATA_SIZE).
...