Hi,
I am using multiperipheral mode in ble_app_hrs using the ble_app_multiperipheral example taking the functions on_connected and on_disconnected while connect and disconnect...
Hi,
I'm using nRF52810 on SDKv14.2 and I have changed the bootloader from 52832 to work for 52810. I could do OTA now. I found that the bootloader there is no timeout when...
Is there a way around the issue where bluetooth communication acting as a pass-though terminates the packet whenever null character is found in the packet.
SDK: nRF5_SDK_12...
Hi,
When creating and adding an characteristic to service, what the meaning and difference between these two variables:
attr_char_value.init_len
attr_char_value.max_len...
Hi all,
I have compiled the ble_app_hids_keyboard example for a nRF52832 on a Laird DVK-BL652 breakout board.
I have a tablet running android 5.1.1 and the nordic nRFConnect...
Hello All,
We are using nrf52840 board interface with wiznet550i.
We try to implement mqtt tls 1.2.we get following errors..
I get certificate verification error -0x2700...
Hello,
I have searched through the questions regarding RF PA recommendations but I think none solved my issue.
I would like the nRF51822 to broadcast at +10dBm, so I...
Hello to all,
i'm new to nRF51822 ble developing but have experience with embedded design on various microcontroller;
I have a little problem inside bootloader code: in...
Dear Nordic Support Team,
In previous SDK (6-7) I used to always call softdevice functions when possible/existing to keep compatibility with BLE.
For exemple, PPI functions...
Hi,all.i want to use nrf51822 to drive brushless DC motor and need use 6 pwm signals.Can i generate these signals with nrf51822? Thanks for your reply!
When calling sd_ble_uuid_encode() I get NRF_ERROR_INVALID_PARAM in one project while in another I get NRF_SUCCESS with the same params on same SoftDevice(S110 8.0.0) on same...
Hi,
Can a peripheral choose among multiple central?
Consider a situation where I have a 3 centrals.
Lets say CentralA, CentralB and CentralC with,
CentralA - High...
I am really puzzled by this and although I've read all the relevant answers in the Q/A I'm still unable to do the following:
do non-selective scanning with central device...
i can not re-download application by keil4
i download softdevice and the application to Equipment by nrf51422 then it can works
but when i disconnect usb line and connect...
i want to use codeblocks to compile and download program to nrf51422
so i try to compile example in keil/ARM by codeblocks
then it always show up error
like this
" C:...
Hello all, I have implemented own bond manager with saving context to flash on nRF51422 SD110.
The problem is in getting IRK and creating a whitelist with it after disconnection...
my dk board is nrf51422 and nrf 52382,
the central role is nrf51422, and the peripheral role is 52382.
my sdk version of 52422 is 10.0.0 and 0.9.2 for 52382
the project...
I'm trying to get a module with an NFR24L01+ on board to send a simple data transmission from a pic micro but after a couple of days of trying various combinations without...
i find that the macro APP_ERROR_CHECK call the macro APP_ERROR_HANDLER
do \
{ \
const uint32_t LOCAL_ERR_CODE = (ERR_CODE); \
if (LOCAL_ERR_CODE != NRF_SUCCESS) \...
HI all:
Because the application code is relatively small, bootloader is used dual_bank_mode, but now the application code becomes large, OTA can not upgrade, I would like...