the proximity example is running ok. but when I modify the length of the alert_level I have the following error on the server side that I am not understanding.
476;16:12...
Hi all,
I'm working with the nrf51422 and the nrf51822 and I was wondering what the current status of the over the air DFU system is.
I'm using SDK 6.0 and I managed...
nRF24l01+ at a transmitter module one time successful transmission show & after 1 sec failed also . if any doing programming with atmega32 ,please send code for TX & RX ....
Hello,
can the radio notification and radio disable APIs be used to use the radio hardware from the application layer?
Background of my question is, that I have an application...
Hi,
I am using central s120 with peripheral s110. The connection to the peripheral is depending on the name advertised by the peripheral.
When connection is done, the...
Hello,
I am trying to ecrypt some data in order to send some data encrypted in the MINOR and MAJOR adverts of the device.
I used this code to ecrypt the data ( this is...
Hi,
i use anRF51822 with soft device 7.
I run the UART app on my iPhone 4s with ios7 and on the nrf51822 board the ble_app_uart with keil uVision5.
Both devices connected...
Hi,
I'm having trouble writing a long characteristic. I'm using the pc-ble-windows code from https://github.com/NordicSemiconductor/pc-ble-driver . I've compiled this and...
Hi,
I am using SDK15.2/3, I know the SDK peer manager has a feature to delete the oldest bonds if the flash memory is not enough to store a new bond. In this case, whether...
I want to transfer some data stored in nRF51822 to another BLE central device. I guess the idea is very similar to "ble_app_uart" example except that I don't need the part...
Hi. I have a project based on multi-link central with NUS service.
I can connect to multiple peers ok at the same time, disconnect etc. However if I am connected to one...
The Declaring attributes section of Zigbee stack API overview ( https://infocenter.nordicsemi.com/index.jsp?topic=%2Fcom.nordic.infocenter.thread_zigbee.v3.0.0%2Fusing_zigbee__z_c_l...
Interfacing to CC3100 and need to send socket data over spi that is 1400 bytes.
Assuming I would need to send 200 bytes X 7 and try to get the list array to work.
But...
I thought I had the logging figured out but when I try to develop the application, I always seem to end up with the same error.
I don't understand what causes this and thought...
Hi Experts!
I read some posts related to current measurement, and i have a question.
if SB9 is not opened, current consumption is increased??
i have a Source Measurement...
SDK 15.2 API 6.1 SES
I am trying to read manufacturer data. I know i am advertising it because i can see it on the nRF connect app on my phone. When i try an dparse the...
I'm trying to send data string from Central to Peripheral device using NUS.
If string length exceed 20 bytes then function return err_code = 12 (NRF_ERROR_DATA_SIZE).
...
I have some test code that uses VLOC_USER and when i write with authorization the data seems to get scrambled.
when i use
p_evt_write->data[0];
to get the data it is...
Hello,
I am new to Nordic devices. So it is tough for me to understand PWM examples. Can you provide me the simple code of PWM? Basically, I want to give a specific brightness...
I read somewhere that nrf52 has default tx power 0 dBm (I use S132 softdevice). I would like to set it to +4 dBm. How to do it? I know sd_ble_gap_tx_power_set function exists...