Hello,
I upgraded nRFgo Studio software to version 1.17.0. Installation goes OK but the application crashes every time I try to launch it after installation process.. Then...
Hi,
i tried to send data from ios 7 via tx_characteristics(like in UART example) but received error:
didWriteValueForCharacteristic 2A38 error = Error Domain=CBErrorDomain...
I have been trying for a few days now to get my environment setup for development with the nRF51822. Since there is no official configuration for the Mac w/ Eclipse I have...
Apologies if this has been asked before but did search for 'format' in faq and got nothing.
I have been answering to questions.
In my answer I place hard empty lines....
Hi
i use nrf51822 s110 "hrs" example to transmit the data to ios.
I need to add an option to send back some data (from ios to nrf51822). 10 bytes maximum .
how can i implement...
Hi
i use the hrs example to transmit the data to ios.
but i need to add an option to send back data (from ios to nrf51822). 10 bytes maximum .
how can i implement...
Hello,when i get connected to the phone,when i call err_code = ble_hts_measurement_send(&m_hts, &simulated_meas) and err_code = ble_bas_battery_level_update(&m_bas, battery_level...
Hi,
I'm having trouble writing a long characteristic. I'm using the pc-ble-windows code from https://github.com/NordicSemiconductor/pc-ble-driver . I've compiled this and...
Hi,
I am using SDK15.2/3, I know the SDK peer manager has a feature to delete the oldest bonds if the flash memory is not enough to store a new bond. In this case, whether...
I want to transfer some data stored in nRF51822 to another BLE central device. I guess the idea is very similar to "ble_app_uart" example except that I don't need the part...
Hi. I have a project based on multi-link central with NUS service.
I can connect to multiple peers ok at the same time, disconnect etc. However if I am connected to one...
The Declaring attributes section of Zigbee stack API overview ( https://infocenter.nordicsemi.com/index.jsp?topic=%2Fcom.nordic.infocenter.thread_zigbee.v3.0.0%2Fusing_zigbee__z_c_l...
Interfacing to CC3100 and need to send socket data over spi that is 1400 bytes.
Assuming I would need to send 200 bytes X 7 and try to get the list array to work.
But...
I thought I had the logging figured out but when I try to develop the application, I always seem to end up with the same error.
I don't understand what causes this and thought...
Hi Experts!
I read some posts related to current measurement, and i have a question.
if SB9 is not opened, current consumption is increased??
i have a Source Measurement...
SDK 15.2 API 6.1 SES
I am trying to read manufacturer data. I know i am advertising it because i can see it on the nRF connect app on my phone. When i try an dparse the...
I'm trying to send data string from Central to Peripheral device using NUS.
If string length exceed 20 bytes then function return err_code = 12 (NRF_ERROR_DATA_SIZE).
...
I have some test code that uses VLOC_USER and when i write with authorization the data seems to get scrambled.
when i use
p_evt_write->data[0];
to get the data it is...
Hello,
I am new to Nordic devices. So it is tough for me to understand PWM examples. Can you provide me the simple code of PWM? Basically, I want to give a specific brightness...
I read somewhere that nrf52 has default tx power 0 dBm (I use S132 softdevice). I would like to set it to +4 dBm. How to do it? I know sd_ble_gap_tx_power_set function exists...