I am trying to get a WiFi project working using the nRF52840DK and nRF7002EK . I use a 3.3V power source that is supplying power to both nRF's in parallel. For the nRF7002EK...
Hi,
I'm developing firmware for the nRF52840 DK using nRF Connect SDK v2.9.2 , and I’m running into a problem that didn’t occur in v2.8.0 .
My project uses Zephyr and...
I was wondering if there was a way to use the Nordic Power Profiler Kit II (PPK2) as an ampere meter, and be able to determine more details about what portion of the current...
I'm trying to run the DFU sample l9_e5_sol on a custom board using the nRF5340 and SDK version 3.0.2.
My goal is to perform DFU over BLE using external flash. However, before...
I am using a custom board with a nrf5340 chip on it with vs code and sdk/toolchain of 2.9.1 and the bmi270 sample. I am getting and issue with my bmi270 accelerometer when...
I am receiving an error when connecting to a custom board by running nrfjprog --reset, any similarly with any other commands that require connection.
I am connecting through...
I am receiving an error when connecting to a custom board by running nrfjprog --reset, any similarly with any other commands that require connection.
I am connecting through...
Hi,
We are currently trying to design a system using one of the nrf5 bluetooth chips. However, we are still in the process of designing a functional antenna and need to...
Hi, I am trying to implement an example that support multiple peripherals (HRS & UART). When I get a connection (from either) I get the BLE_GAP_EVT_CONNECTED. How can I differentiate...
What is exact difference between heartbeat and health models?
I know heartbeat can be used to detect node outage, but so can be health message?
So, which one should be...
When starting up the device with the nRF5 SDK 3.2.0 for mesh, even though the model and subscription list state is loaded from flash, it is stored again right afterwards....
To the kind attention of Nordic support team,
I was reading this blog https://www.ericsson.com/en/blog/2017/12/wake-up-radio--a-key-component-of-iot
May I ask if Nordic...
After Downgrade protection in the NRF9160 has been set with AT%XPRODDONE=1, switching it off with AT %XPRODDONE=0 returns ERROR. Is there a way to disable downgrade protection...
Hello DevZone,
Is there a way for hardware to update the timer capture register?
I want to create different frequencies using a single timer. Next to the timer, Bluetooth...
I am using Nordic proprietary RF receiver and transmitter. I want to display the received data on my serial terminal using UART pins (any 2 pins as Rx-Tx) .
When I tried...
Hello,
i'm writing a code for NRF9160DK where i plan to send a HTTP POST request to a test server when i push BUTTON1 on DK. To achieve this result i studied separately...
Hello,
I have an issue since today. Indeed I worked for a few weeks on the nRF52840 and everything was alright. I used a dock to connect the nRF52840 by serial port with...
Hi,
I have an application where an nRF52840 DK(1.1.0) is configured to work as both central and peripheral. I want to set a lesser duration for advertising with whitelisting...
I have added lbs_service from ble_app_blinky service within ble_app_glucose example. I made changes in main.c and EMPROJECT File accordingly. I have added ble_lbs.c file in...
I need help in implementing Monitor Mode Debugging (MMD) using Segger Embedded Studio development. Can you please provide detailed help and explanation please?
Hi Devzone:
After searching through the forum I found out that nrf_fstorage_write can only make 1 to 0. So each write needs an erase operation preceding it.
But erase...
Baseline: CLI example on the 52832 with SDK v15.3
I assume the issue will be some more undocumented fix.
sdk_config.h