Hello All,
I have problem with ble_app_uart which are not support DFU services.
When I am implement both services device will not advertise. and when ble_nus uninitialized...
[symptom]
I want to update my application/bootloader/softdevice by DFU.
Steps are shown below.
bootloder/softdevice update
if 1 step is done, application update...
Dear Developer Zone,
I am new to ANT and am looking for someone to help me to setup an example 15 channel (14 devices) ANT network using the S332 soft-device to test communication...
Hello,
i am working with the Enhanced ShockBurst proprietary protocol and i am wondering where I can find the sources of this protocol, so that I can do some changes. ...
[uart - Copy.rar](/a master _error.png ttachment/3cc01f5e2484d2b0f33e62befd3e6a62)
hello there
I am interfacing master nrf51 dk with nxp's slave lpc11u24
(1) my main...
It is good practice to prefix the includes from one's C libraries with a directory so that they are all part of the same 'include namespace'. Unfortunately the Nordic SDK...
I'm migrating an old (but working) app from the S110 5.2.1 (SDK 4.X) to the latest SDK9/S110 8.0. I've read the migration doc, and I'm following the examples carefully (specifically...
Hi,
I downloaded latest version of SDK and all examples resented there are for nrf51422.
Can I use those examples for nrf51822?
I'm using ukeil and I can only select nrf51422...
Our chip seems to be running at ~500uA and I'm trying to narrow it down.
I'm doing periodic battery level checks on a timer using the ADC HAL. So at init I call nrf_adc_configure...
I use s110 send notification to s120 in 1 - 1with 7.5ms connect interval,but the data maximum data throughput is only 21.3 /2 kbps.how can i do to raise the throughput???...
i use s110 send notification to s120,and set connect interval with 7.5ms,but in actually the connect interval is 15ms!!I see s120 softdevice specification,s120 as client which...
Hi,here i met an issue that when i set address type in public mode by funtion sd_ble_gap_address_set(),and then the advdata packet data was all zereo.This project was created...
Dear ladies and gentlemen,
There is not much information about the RESET pin in the datasheet. I guess, it doesn't have an internal pull-down resistor, but when I look at...
Hi,
I have a problem configuring readback protection using boot.
It seams that the BOOTLOADER stops when trying to read some information from the softdevice if readback...
HI:
i want to use peripheral and central function.and i can switch it to work peripheral or central state when i need.which stack should i use.s120 or s130.
I am using CMSIS RTOS (RTX) to implement an application for the NRF52 DK. I have found an error in the SVC handler that results in a hard fault when calling a soft device...
Hi all,
I was trying to use the S130 Softdevice but the uart peripheral doesn't work properly... I am trying to send three bytes, but only one appears. Flow Control doesn...
I am using a mutex to protect a serial debug printout.