Hi
I am trying to port some PWM code from the NRF54L15 it uses HAL access because i have found it has faster writes which are useful for my application (testing latency...
Hello,
I have recently upgraded from v2.9 to v3.0.1 and have noticed that the mesh security has changed from CONFIG_BT_MESH_USES_TINYCRYPT to CONFIG_BT_MESH_USES_MBEDTLS_PSA...
Hello.
We're trying to expose and use the Wifi stack in micropython in our project for the nRF7002. We've managed to get Wifi scanning to work (based on the sample code...
Has anyone experienced the following error when Flashing (and debugging) from within VS Code. I have no idea what has happened, but it has hit several projects.
Even though...
Hello,
I have a firmware that sends every 15 min a packet to nRFCloud using nrf_cloud_coap_json_message_send().
The code is working great most of the time : hundreds of...
Hi Nordic Team,
I would like to confirm whether enabling APPROTECT also implicitly enables Secure APPROTECT, or if these two protection mechanisms need to be configured...
Hi,
The Thingy 91 X uses a shared antenna for BLE and Wi-Fi. I can see from the Hardware Guide and the schematics that there are several hardware connections between the...
Hi,all.i want to use nrf51822 to drive brushless DC motor and need use 6 pwm signals.Can i generate these signals with nrf51822? Thanks for your reply!
When calling sd_ble_uuid_encode() I get NRF_ERROR_INVALID_PARAM in one project while in another I get NRF_SUCCESS with the same params on same SoftDevice(S110 8.0.0) on same...
Hi,
Can a peripheral choose among multiple central?
Consider a situation where I have a 3 centrals.
Lets say CentralA, CentralB and CentralC with,
CentralA - High...
I am really puzzled by this and although I've read all the relevant answers in the Q/A I'm still unable to do the following:
do non-selective scanning with central device...
i can not re-download application by keil4
i download softdevice and the application to Equipment by nrf51422 then it can works
but when i disconnect usb line and connect...
i want to use codeblocks to compile and download program to nrf51422
so i try to compile example in keil/ARM by codeblocks
then it always show up error
like this
" C:...
Hello all, I have implemented own bond manager with saving context to flash on nRF51422 SD110.
The problem is in getting IRK and creating a whitelist with it after disconnection...
my dk board is nrf51422 and nrf 52382,
the central role is nrf51422, and the peripheral role is 52382.
my sdk version of 52422 is 10.0.0 and 0.9.2 for 52382
the project...
I'm trying to get a module with an NFR24L01+ on board to send a simple data transmission from a pic micro but after a couple of days of trying various combinations without...
i find that the macro APP_ERROR_CHECK call the macro APP_ERROR_HANDLER
do \
{ \
const uint32_t LOCAL_ERR_CODE = (ERR_CODE); \
if (LOCAL_ERR_CODE != NRF_SUCCESS) \...
HI all:
Because the application code is relatively small, bootloader is used dual_bank_mode, but now the application code becomes large, OTA can not upgrade, I would like...
My PCA10001 board is getting detected in nRFgo studio and i can even program it but its COM port is not getting detected in device manager.
I dont know what happened but...
Hello Nordic--
We're most of the way through qualification testing on an nrf51822 and the testing house had a question about the PIXIT values for RF-PHY testing. I sent...
Hi,
I find three different states that is related to DFU and app_button libary.
1, no DFU(that is no bootloader), but using app_button libary, there is no 0.9mA current...