Hi,
I find the CSCS example program reading zero at low cadence levels below around 50 rpm.
Using ble_peripheral example ble_app_cscs loaded into the PCA10040 board or...
I had manged to deploy and configure mesh networks on Nordic Thingy devices based on these 2 examples separately. 1. Generic OnOff models https://github.com/NordicPlayground...
Hello,
I am unable to access my SRJ profile with email id [email protected] due to two factor authentication. i do not get anything in the google authentication app...
The link for downloading nRF6939 live cd v5.4 is broken.
https://www.nordicsemi.com/Software-and-Tools/Reference-Designs/nRFready-Smart-Remote-3-for-nRF52-Series/Downlo...
Using one ADC, the current can be reduced to about 40uA after the ADC value is taken. Using a two-channel ADC, after the ADC value is taken, the current stops at about 0.4...
I'm searching for a software engineer who can help us getting OTA support between nRF52810 and PIC16 MCU.
nRF52810 must have command- and data mode over UART, Pic controler...
Hi,
How can I know the value of the interval and scan window for an nRF51 dongle? Is there any way to change these values? W hat is the valid range for both parameters ...
Dear Nordic Team,
Thanks for supporting.
Currently i am work with secure DFU as per this link: https://devzone.nordicsemi.com/b/blog/posts/getting-started-with-nordics...
Hi guys:
I was confused with the problem of "re-pair".
The condition is my device can only bond one phone (I was set the DEVICE_MANAGER_MAX_BONDS to 1).
Then I successful...
HI, I have nrf52832 and I am using latest SDK 14.2.0. I am using FDS and the problem is that before setting up BLE fds_record_write works fine but after setting up BLE all...
Hi there..
I've recently jumped back on development of a board I had made a while ago but have forgotten everything and am starting from scratch as computer was reformatted...
Hi,
I am trying to use nRF52840 boards but I am not able to write on them using JLinkExe nor nrfjprog. However, when drag-and-drop-ing a built example application, it works...
I want to use the radio interrupt to receive data, but I only entered the interrupt once at initialization, and I can't enter the interrupt again. But use the commented out...
Hi,
I'd like to know: when using Buttonless Secure DFU Service without bonds, wich is the proper way to prevent a central device to s et a new advertisement name for the...
Hello,
I've got some trouble using Nordic Uart Services,
I am using ble_app_uart example and after connection receiving bulk data from mobile app & sending it on UART...
Hi,
I have build pc-nrfconnect-rssi accodring to instructions. Though the locally build version responds very slowly compared to the officially installed version. No matter...
I am using a nRF52832 and v14.2 of the Nordic SDK. I have a question about the PWM Driver. I have the pwm driver working and driving an LED, but it is unclear to me how to...
Hello!
I am currently developing an application for the nrf52832 using Segger Embedded Studio as my IDE.
The application is not utilizing any softdevice but I would...
Hi,
We are using an nRF52832 with Soft Device S132 in a project. It has been requested that we should advertise as connectable with our own service and characteristics,...
Hi
In the NRF_MESH_PROV_EVT_COMPLETE event, I call
ERROR_CHECK(dsm_address_publish_add(m_next_unprov_address,&m_device_address_handles[m_next_unprov_index])); ERROR_CHECK...
Hello,
I want to be able to toggle blocking RTT output when using the log module.
Before in SDK13 I could just set SEGGER_RTT_CONFIG_DEFAULT_MODE to 2 in the sdk_config...