Hi,
i am using SDK v8 with softdevice v8,using master control panel pc application,added custom service and characteristics to application,problem is characteristics value...
There is the board mark on the chip like n51822CEAAD01350A0, where DO is Build code, 1350 is tracking code(YYMM), A0 is lot code.
My question is how can I get those codes...
I'm trying to debug a randomly occuring Hardfault. In trying to trace down the source I read the CPU registers use the Nordic hardfault_implementation.c which grabs the register...
Dear nordic employee
my purpose is send a data the length is from 150 to 273
when my server device send data by sd_ble_gatts_hvx(the send length is fixed 10 bytes) ...
Dear nordic employee:
The service I want to find is the sound service of the thing52 thingy sound service
I tried to modify the HRT_central_client project to find the...
When I was using the device as peripheral, I was wondering when the Softdevice notified BLE_GAP_EVT_SEC_PARAMS_REQUEST and BLE_EVT_SEC_INFO_REQUEST:
1, when peripheral...
good day,
i am using nrf52832 (pca10040) with sdk17.1 and would like to hide/stop the buttonless du service and only make it appear when a command is received. but based...
nrf connect extension for VS code cannot display asset of application such as source code, input file, output file ,suddenly, for no reason.It used to display asset. I had...
Dear ,
I use nrf connect programmer to connect nRF52840 but it show ERROR "Could not fetch memory size of target devkit: Error: Error occured when get library info. Errorcode...
I have used the pca10059 with an external programmer, overwriting the USB DFU bootloader on the board in the process.
Now, I would like to restore the original bootloader...
Hello, We use MDBT42Q_512KV2 module which includes nrf52832 IC. I want to know about the max bearable TLP (Transmission Line Pulse) voltage for the IC.
Hi,
I've implemented a buzzer service with the following code:
m_top is 1880 such that I get a C note/tone at the buzzer.
I also use the following evt handler function...
To the kind attention of Nordic support team,
using Nordic ble sniffer, I can see these notifications, and there is sometime this bad MIC packet.
Our connection is not...
Hi, I am calling sd_ble_gatts_hvx() api every 100 milli second. but BLE_GATTS_EVT_HVN_TX_COMPLETE event is coming a little late. Initially, for few seconds, this is not observable...
can you please help me to connect without error
example code ble peripheral i try all examples but get same error, i use sdk v15.3 and segger embedde studio v 6.32
Hello! We are trying to sign our data using ECDSA ( https://developer.nordicsemi.com/nRF_Connect_SDK/doc/latest/nrf/samples/crypto/ecdsa/README.html ) . We are comparing the...
I am developing a time sensitive application using multiple peripherals that are sending sensor data to a central using softdevice 15.0.
Every connection interval I should...
Hi,
I have an environment variable with newlines and that is messed up by the VS Code extension. It seems that the extension tries to parse and rewrite the whole environment...
We're evaluating options regarding pre-certified modules. Usually modules are certified using a specific SoftDevice. The module we liked to use is FCC (and more) certified...
Hi Nordic team,
I’m testing neighbor cell measurements with 9160DK and see completely different results with 2 SIM cards:
Google Fi SIM (T-mobile): 1 neighbor in most...
Hi, We are using NCS v2.0.2 on nRF52840. I have a question: what is the best practice to re-configure uart/gpio at runtime? What we need: 1, Configure 2 IOs as UART TX/RX...