Hello,
We have an NCS v2.2.0 nRF5340 application with MCUboot that requires GPIO control of a few pins extremely early in the startup process. We have a signal "A" pulled...
Sorry if this is too off topic, I actually don't have any problem with my nrf52840 dongle, but the App I'm communicating with. But maybe someone of you has run into the same...
Hello!
We are planning to purchase an electronic component nrf52840 and produce a finished product on it.
question
1. Will it work immediately on the ZIGBEE 3.0...
Dear Sir .
I have on my custom board 2 spi , spi1 and spi3.
&spi3 { status = "okay"; compatible = "nordic,nrf-spim"; sck-pin = <31>; mosi-pin = <9>; miso-pin = <30>;...
Hi,
Now I use Nrf52811 to develop a product. I use the 125k long range radio + 4dB mode.
I read through its specifications and found no corresponding...
Hi,
Now I use Nrf52811 to develop a product. I use the 125k long range radio + 4dB mode.
I read through its specifications and found no corresponding...
Hi.
I programmed the firmware in " https://github.com/NordicSemiconductor/pc-ble-driver " share folder to a nrf52840 dongle.
NRF_SD_BLE_API=6
I took the example heart...
I can send a command to a custom cluster through the Zigbee CLI, which is installed and running as a Coordinator on a nrf52840 dongle.
However, I must respond to commands...
Hello Nordic!
We are going to develop the device under the following conditions - nRF52832 - SDK11 - SoftDevice S132 v2.0.1
We are planning to add Serial DFU feature to...
Hi, I am porting an app from SDK 14.2 to SDK 16 (nrf52832) and noticed some strange behaviour with nrf_delay_ms - it is not delaying anywhere nearly long enough. I have built...
I have been able to program the nRF52 DK perfectly the past couple weeks and just recently got an nRF9160 DK.
I tried to update the 9160 DK to the latest firmware using...
Hi,
What is TWI transaction manager? Is this a hardware or just software library? Does it work with TWIM (with easy DMA)?
I have a suggestion that when making an example...
I see that there is a significant drop in average current with DC/DC on, will this also be true if I already have a 3V from a BMS (with its own DC/DC) supplying to Vdd (won...
Hi, I have one service UUID ffe0 that has two characteristics: one of has UUID ffe4 use for "notify" and other one has UUID ffe5 use for "write and read". Now i want to get...
Hello,
I'm having a system consisting of an nRF52 and another processor, with UART between them. If the other processor restarts, nRF's RX line will be pulled low for some...