I'd like to read and write data to the reserved app data space while in the bootloader. Is this possible with pstorage?
Because the BOOTLOADER_SETTINGS_ADDRESSS = 0x0003FC00...
Hi,
I am using 'pstorage_update' to store data in the internal flash. Whenever the number of bytes that should be written matches the size of a storage block everything...
Has anyone tried to generalize this example to different sized variables? What I would like to do is allocate a data structure, write that to flash, and recall it at a later...
I've a PCA10036 V1, I change the IC to nRF52822 QFAA-B016. With nRF5_SDK_11.0.0-2.alpha_bc3f6a0 and SD: s132_nrf52_2.0.0-7.alpha_softdevice, the programme started but if I...
Hi
We are developing software for the nRF51 with Keil under VirtualBox. Previously we used the PCA10000 dongle with the Master Emulator and MCP without issue. Now, with...
We are using nRF51822 for our products.
We want to know the min value of "Receiver sensitivity" when we use this chip for BLE.
The Datasheet says "Receiver sensitivity...
Dear
The BLE Multi-link example (ble_app_multilink_central and ble_app_multilink_peripheral)
shows how one central device can connect to multiple peripheral devices. ...
I need to maintain and update firmware written with 15.3 SDK on an nRF52832 on Windows 11. What is the exact software and tools I need to do this. The latest Segger development...
Hello,
My use case is the exact same use case as this forum post . I'd like to run BLE and Radio Test sample on the nRF5340. The device would be in 2 modes:
- BLE
-...
Hello,
I try to figure out, how to correctly setup MCUboot for an nrf5340, so that:
Application is updatable
BT Stack is updatable
Firmware Updates are encrypted...
I am trying to enable a watchdog and then stop it. i closely followed the datasheet way to do this. the problem is that the watchdog once enabled will always fire. i want...
I'm working on nRF5340 custom platform (NCS 2.6.1, Zephyr 3.5.99). I use MCUBoot immutable bootloader and external QSPI NOR Flash for slot-1 partition during DFU.
This is...
Hi Nordic Team,
I am working on the Matter Smoke/CO Alarm example with ICD (Intermittently Connected Device) support enabled.
My operational mode is working correctly...
I'm trying to replace HM-10 module with a RAYTAC MDBT42TV-DB-05 for a transparent UART (serial passthrough) application. I've configured all the parameters and GATT settings...
in fact , I have the while sdk directorys. in c:/ncs/v3.1.0 but,the nrf extension in vscode cannot recognize it. it always info me to install a sdk in welcome page. so, I...
I am using nRF52840, we have an issue which seems like a standard issue with nordic switching between regular battery and a coin cell backup.
I need to know the following...
Hi Support Team
Is the ifft the measured distance? I test the channel sounding sample in NCS v3.0.0 and find that the ifft distance error is relatively large. How to optimize...
My new PC could not find PPK in the power profile menu, even I installed different version nRF connect desktop or different Power Profile versions. I always could not find...
Hi:
I'll be using the Raytac Bluetooth Module in my project.
Imagine that the Bluetooth Module has a Bluetooth connection established with the smartphone (Android or...
Hi,
I am programming with ncs v2.9.0 based on nrf52833 chip
And base on peripheral_hid and central_hid
Testing that peripheral send data continuesly to central,and about...
Hello
I am attempting to perform BLE certification using a third-party module for the nrf52832.
Should I select the nRF Connect SDK QDID for all design items?
Or, should...