Hi,
I have 3 nRF51 DK pca10028 v1.1.0
I compiled and run power profiling example and after that I cannot flash or connect to the devices (tested in all three of them)...
Hi Guys,
Thanks for your precious time and insight. Let me try to explain what we did,
We have developed a custom board
After assembling the board, we do a bare board...
Hello all, this tutorial goes to a fellow named Emil who helped me with this project.
Number 1_ Make sure you set up the terminal viewer For debugging with real.You need...
Seeing recent response to my original question on multiple chip selects, I've opted to share a modification to spi_master that I've implemented in part to make handling some...
What is the official status of the Softdevice Serialization for S130 in SDK 9? I could see an older answer on how that was removed in SDK 8 but since almost half year has...
Hi
The documentation for the new feature in S110 v8 to change the gatt table size says that to change it the linker configuration needs changing .
This means it is a...
I used to be able to see my development kit in nRFgo studio and flashed S110 onto the chip. Now all I see is: "No boards connected". I am still able to flash programs onto...
I am attempting to do some development using the usbd_hid_generic example peripheral code. I am using some C++ libraries in this project, however there is syntax in the usbd...
I would guess that's basically the whole point of the structure, but I want to make sure that the location of the SoftDevice Information Structure and the relative positions...
I want to use the nrf24l01+ with the se2436 apmlifier, but the input of the amplifier requires an input of 100ohms balanced, while the nrf24 has a balanced output of 15ohm...
Hello,
I am using following component for my project, 1-nrf51822,2-SDK 11 3-S130, 4-BLE400 board, 5-Keil IDE. I am also using SDK 11.x HID example for my base program....
Hi,
I try to use the nRF sniffer but it doesn't display anything.
System used :
Windows 10 Family x64
Wireshark 2.4.4
Python 2.7.14 (in C\Python27 included in...
When the Softdevice is not enabled, can the nrf_nvic_ functions be used? When I never enable Softdevice but call err_code = sd_nvic_ClearPendingIRQ(RADIO_IRQn) I get error...
I am working with the DK-52 and SDK 14.2. I am generating two PWM signals using the pwm driver.
Everything works as expected on PINS 11 and 12.
If I change pins to 5...
I'm using nRF52832 SDK board with softdevice s132_nrf52_5.0.0 and SDK 14.2.
The program compile without an error. I tested the led and timer separately and these work.
...
Hey all,
I tried to build my project in the Keil µVision IDE.
But everytime I get the same error and I can't figure out where the problem should be.
I searched for the...
I would like to call sd_power_system_off in my error handler. The product is at a stage where occasional errors still occur as the devices are deployed "in the field" for...
We have a custom board solution with an BLE module from Laird, that uses nrf51822 IC, as a gateway. Code was written in Keil and we used SDK v 8.1.0. Originally we didn't...
According to BLUETOOTH SPECIFICATION Version 5.0 | Vol 3, Part G page 2248
Exchange MTU procedure is initiated by the Cilent, and only be initiated once.
But by looking...