Hello,
I am using nrf52840 DK, Segger Studio IDE, Win10.
My application is I want to transfer the image from iOS to the DK board.
I am aware of the Image Transfer...
Hello, i intsalled the software stack for use with latest release of nrf sniffer package.
By starting the capture process with wireshark 3.2 i have noticed an issue:
In...
I have a project where we have 2 nrf51 that need to be time synced with eachother.
The problem is they are placed on the body one on the back and one on the chest of a person...
on the page
https://infocenter.nordicsemi.com/index.jsp?topic=%2Fsdk_nrf5_v16.0.0%2Flib_crypto_backend_micro_ecc.html&anchor=lib_crypto_backend_micro_ecc_install
step...
Hi,
In our one of the product we are using Nordic nRF52840 MCU and we compiling this application code in windows with SEGGER Embedded STUDIO IDE Version 4.30a and Tool chain...
Hi,
We made an online course on Bluetooth Low Energy, includes BLE Fundamentals & Architecture, step by step implementation of Environment Sensing service development...
Hi All,
I use 2 peripheral and 6 Central roles coexisting.
Not clear the order of conn_handle number assigned by SD during BLE Connection.
For example.
After Central...
I am new to nRF programming. My "far away goal" is to make a BLE sensor mesh with a centralised data collection.
Currently I am deciding what libraries to start playing...
Peripheral device has 2 services,but central can find only 1 service(0x1001).
I want to find other service(0x0001)
According to the message seems to be looking for 0x1001...
Hi,
I'm using the nRF51 dongle with nRF SDK 12.3.0 and the S130 2.0.1 SoftDevice to implement a BLE central. The dongle repeatedly connects to a BLE peripheral, performs...
I'm running the PB Remote Client on a PCA10040.
I have 2 servers running on PCA10040 boards.
Watching the log whilst debugging the client, I receive the following: ...
Hello all,
I am new to nRF platfrom, I am working on a protect which contains multiple BMD-200 modules with nRF51822 controller. It has to transfer some data via UART,...
Per this blog, I understand that the nRF52's ANT pin must be matched to 50ohm via L1/C3 and that the antenna must be matched to 50ohm. Hence a trace with 50ohm characteristic...
Hello, the title is pretty descriptive.
I've tried to read through previous questions and got a rough idea but decided that it would cost too much time for me to explore...
I am working on a ble application using an nRF51822 that requires low power consumption. I'm curious if on average the observer or the central role will consume less power...
We have our own custom board using nRF52832 (via Laird BL652 module). Until recently, we have been programming our application, bootloader and softdevice using the PCA10040...
SDK12 and SD 132 v3.
I have my code working for HVX from the peripheral. I can HVX send up to 80 bytes on one characteristic in one call (ATT MTU was set to 83 and DLE...
The NRF52 product spec suggests:
"The input buffer of a GPIO pin can be disconnected from the pin to enable power savings"
I've found that gpio.h provides the function...
Here is a snippet of my debug log:
nrf_sdh_freertos: Creating a SoftDevice task.
nrf_sdh_freertos: SoftDevice task not created.
app: ERROR 4 [NRF_ERROR_NO_MEM] at ...