Has anyone experience of successful TICK_DV calibration for nRF9E5? What order of accuracy should be achievable?
In my application I maintain a software RTC clocked by...
Hello,
I manage to work with new S310 V2.
I use S310 for hrm only. Saying so also not for DFU service.
I have own proprietary method for transfering application images...
I am working on an application and need to get the exact time that the master node receive advertising from the slave node. I tried with PPI and it's ok to capture the Radio...
Hi, could you please tell me if my assumptions below correct?
Measuring a (ratiometric to VCC) analog signal and selecting VDD_1_2_PS as the reference selecting AIN_NO_PS...
When I initialize the SoftDevice with SOFTDEVICE_HANDLER_INIT(NRF_CLOCK_LFCLKSRC_XTAL_20_PPM, false); // Sets up Crystal Source to 20ppm 32.7628kHz
The project I based...
I am trying to make a product with NRF8002B. I finally have the product prototyped. The user will connect to the device, beep, light up, and track. It will always stay on...
I am using this MBN52832DK and find out this nRF5_SDK_17.0.0_9d13099.
Trying to import into Segger Embedded Studio but rebuild come out error.
using the nrf52832_xxaa...
Hi all,
I would like to have a semi-duplex communication link over one pin (+GND). The nRF will act as a pure slave device which responds to, and acknowledges, commands...
Hello, we understand that the Nordic framework, by default, restarts advertising on disconnect. I learned that here, thank you:
https://devzone.nordicsemi.com/f/nordic-q...
I'm currently running on nRF Connect SDK (hash: 4b012fb4882f0ddd3de9f339ebc5a3f1c3cacd4a). I'm running a connection between a nRF91+nRF52840 (as central running NUS_C) using...
I have an nRF52840 board that fails to connect to Linux over USB. The board powers on and the green LED at the lower left of the PCA10056 flashes on/off rather quickly. But...
There is a bug in fds.c file, Please go through the below code snippet.
I do not return from fds_gc(), execution stays there for infinite.
More information:
1) #define...
Nordic nRF52840, with regards to stored security keys in flash, some wear leveling schemes move data when being updated but do not erase data from the old location. This is...
Based on several posts I've found on the forum, the notification queue size is automatically set by the stack based on the connection event length (NRF_SDH_BLE_GAP_EVENT_LENGTH...
Hello, I have developed a program that reads (with I2C) a temperature sensor and sends it to the central board. The central board is a NRF52480-DK. I have tested the peripheral...
Dear Sir.
I was testing dfu mode with an nrf52840 dk and held down the IF BOOT/RESET button, then powered up and waited a few seconds before it went into bootloader mode...
Hi,
I'm evaluating the NRF52832 for an ultra low power BLE application where I'm going to use GATT. I've built some prototypes with the NRF52832 and right now I have to...
Our engineers have two questions that they are confused with:
1) When applaying ble techniques, does nodic 52 serious of chip compatible with SIG mesh?
2) When applaying...
Hi there,
we are working on getting type approval certification, and the test lab is asking for fixed frequency software, drivers and SOP.
What we need is the fixed frequency...
Hi,
The actual problem: I want to store some stuff to flash at factory, that is never erased. And I also need another persistent memory that can be written in runtime. I...