Recently s110_nrf51822_7.0.0 softdevice has been released. I cannot find specification where those new amazing features (they are impressive, indeed :) ) are described, so...
Hi All,
Please correct the following in my understanding. Also , i am planning to build a
remote controlled device using a PWM output. How does ATT,GATT and GAP affect/influence...
My board works most of the time are very good,but one time i power down the board when ble connecting and data transmitting,the board can't work when power on.and i can't...
Posting this as separate question as it got no traction in the other thread:
Why are there many of the same include files in the DFU example directory as in the S110 7...
Hi all,
this is not a question per se but rather a warning to those who are attempting to debug Flash related operations with the SEGGER J-Link GDB Server (v4.84a for Linux...
I debugging some function abnormal after OTA problem, and problem with disappear after redo OTA FW upgrade, duirng it I found a problem about Master Control Panel FW upgrade...
Dear ladies and gentlemen,
There is not much information about the RESET pin in the datasheet. I guess, it doesn't have an internal pull-down resistor, but when I look at...
Hi,
I have a problem configuring readback protection using boot.
It seams that the BOOTLOADER stops when trying to read some information from the softdevice if readback...
HI:
i want to use peripheral and central function.and i can switch it to work peripheral or central state when i need.which stack should i use.s120 or s130.
I am using CMSIS RTOS (RTX) to implement an application for the NRF52 DK. I have found an error in the SVC handler that results in a hard fault when calling a soft device...
Hi all,
I was trying to use the S130 Softdevice but the uart peripheral doesn't work properly... I am trying to send three bytes, but only one appears. Flow Control doesn...
I am using a mutex to protect a serial debug printout.
Is it safe to use sd_mutex_acquire in a blocking manner, provided it is only called from main and softdevice callbacks...
As suggested in another post , I asked to our Nordic dealer about nRF52832 chip availability.
Thay talk about 2015 december for mass production , as your direct info confirm...
When i setup DEVICE_MANAGER_MAX_BONDS in 2 and trying to connect third device the nRF 51422 (10028) is freezing and all LED's light up. Why the algorithm in "device_manager_evt_handler...
Hi
I managed to integrate the buttonless DFU example, but while testing it, I have a few difficulties.
I use Lightblue to access my services and enable notifications...
Hello There, I want to connect two slaves to my nRF51422 PCA10028. I came up with the idea of using two master communications which share MOSI AND MISO but have different...
Can the chip be updated from an ANT device to a BT Smart Central. This means it starts its life with an S210 and then gets a serial code update to an S120. Obviously with...
Hi,
I'm testing writing and reading at one of my characteristics in Master Control Panel v.3.7.1 (SoftDevice S110 v7.1.0). As shown in the following figure, firstly I've...
Reading from the FICR seems to produce some results other than what I would expect. For example, reading from offset 0x10C seems to return the flash size (instead of 0x110...